Class ll type A2 biological safety cabinet that protects the user and lab environment from the biohazard factor and prevents cross contamination of various samples used in experiments.
Used in:Clinical & hospitalMicrobiology
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Product description
Suitable for laboratories requiring higher levels of safety grade 2
Intake air and working chamber air are drawn to the underplenum of
the worktop bench ensuring user safety in assured.
70% recirculated air is filtered with the HEPA filter, ensuring product safety is assured.
30% exhausting air is emitted through the HEPA filter, which complies with
the environmental safety requirements of the laboratory.
Equipment that enables safe UV sterilizer
UV sterilization will effect micro organisms at the surface of work table.
While UV light is on, front reinforcement glass door protects the user by blocking UV rays.
Automatically turns off UV light when opening the door or turning on the fluoresent lamp.
Checking the life and performance of filters through a differential pressure gauge
Measure the pressure of the bottom HEPA filter to check the performance and lifespan of
the filter in real time, allowing more safe and efective testing.
Front-side 10 degree tilting design for user's convenience
Ergonomic 10degrees tilting design allows users to make a convenient posture during experiment,
which enables user's neck, shoulders and back comfortable despite long work with the cabinet.
Also user's eyes can be protected from the reflection of light to the glass surface by this tilting design.
Strengthen sample and user safety
Protect specimen and user's safety by inflow and downflow control.
Internal air pressure is maintained with negative pressure compared to the outside, preventing
the contaminated air from escaping through the gaps.
High performance motor to maintain the set airflow velocity
Regardless of filter loads, airflow velocity can be maintained at the set value through
the high performance motor
Easy and quick maintenance due to short filter replacement time
The filters can be replaced in any direction in front or upper of the cabinet, minimizing the time required
for maintenance to be maintained regardless of the installation conditions.
Strengthen validation support using higher performance filters
HEPA filter that enables to remove 99.995% of particles that
have a size greater than or equal to 0.3㎛
Optional ULPA filter that enables to remove 99.9995%
of particles that have a size greater than or equal to 0.12㎛
Product Parameters
- MODEL — PURICUBE NEO 900 — PURICUBE NEO 1200 — PURICUBE NEO 1500 — PURICUBE NEO 1800
- ORDER CODE — PCBN-9-MB — PCBN-12-MB — PCBN-15-MB — PCBN-18-MB
- Size — Inner(W x D x H)mm — 900x575x649 — 1200x576x679 — 1500x576x679 — 1800x576x663
- Out(W x D x H)mm — 970x783x2100 — 1270x783x2100 — 1570x783x2100 — 1870x783x2100
- Weight(Kg) — 190 — 225 — 250 — 280
- Base Stand(H)mm — Stand 705(Included Caster 82)
- Type — Class A2 (70% recirculation as downflow & 30% exhaust as outflow)
- Controller — Display — LCD display
- Function — FL lamp On/Off, UV lamp On/Off, UV lamp timer, Total using / Filter using time
- Door — Weight balanced sliding tempered safety glass(5mm thick)
- Worktop Material — Stainless steel plate 304, HL
- Inside Material — Stainless steel plate 304, HL
- Outside Material — Epoxy powder coated steel plate
- Filter — H-14 HEPA filter : 99.995% at 0.3㎛ / ISO class 5
- Average Airflow Velocity — Inflow — 0.40 m/s — 0.40 m/s — 0.40 m/s — 0.40 m/s
- Downflow — 0.30 m/s — 0.30 m/s — 0.30 m/s — 0.30 m/s
- Gas Valve — 1EA
- Air Valve — 1EA
- Consent — 2EA with reinforced cover(mounted on inside wall)
- UV Lamp — 20W x 1EA — 30W x 1EA — 40W x 1EA
- FL Lamp — 55W x 1EA — 36W x 2EA — 55W x 2EA
- Noise (dB) — < 70dBA
- Power — 230V±10%, 50/60Hz,EU Standard Plug
- Safety — UV lamp automatic switch-off when door's opened, Fuse installed each electric part, Filter life span alarm with buzzer and display on screen
Frequently asked questions
What class of biosafety cabinet is the PURICUBE NEO 1200?
It is a Class II Type A2 biological safety cabinet, protecting the user, the sample and the lab environment, and preventing cross-contamination between samples.
How is the airflow filtered?
About 70% of the air is recirculated through a HEPA filter and 30% is exhausted through a HEPA filter. A differential pressure gauge lets you check filter performance and remaining life.
Is the UV lamp safe to use?
Yes — the front reinforced glass door blocks UV rays while the lamp is on, and the UV light switches off automatically when the door is opened or the fluorescent lamp is turned on.