BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) – 230V
Product code: MX-11267
Easy to handle Fire retardant casing Selectable overdose protection system Splash resistant cover Dosing Relay: Contact close when measure: > set point This instrument has been designed for TDS control in hydroponics, horticulture and water conditioning.
Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.
Ask about this product on LINEPrefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Product description
Adjustable Dry Contact Dosing Relay The BL983329 features a dosing relay that is activated when the reading is above a user programmable set point. Programmable Overdose Protection For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled. Relay Control Override With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump. Multicolor LED Indicator Multicolor LED indicator allows an operator to quickly check the status of the controller. Green = Meter in measurement mode and reading is below the set point. Orange/Yellow = Reading is above the set point and the relay is activated. Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded. Fuse Protected Dosing Contacts The relay dosing contact is rated for up to a 2A load and is fuse protected. Labeled Termination Connections Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.
Specifications
| Range | 0 to 999 ppm |
|---|---|
| Resolution | 1 ppm |
| Accuracy @ 25°C | ±2% F.S. |
| TDS Conversion Factor | 0.5 |
| Probe | HI 7634-00 EC/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included) |
| Temperature Compensation | Automatic, 5 to 50°C (41 to 122°F) with ß = 2%/°C |
| Calibration | manual, with CAL trimmer |
| Dosing Relay | maximum 2A (fuse protected), 250 Vac, 30 VDC Contact close when measure: > set point |
| Setpoint | adjustable from 0 to 999 ppm |
| Overtime | adjustable, typically from 5 to approx. 30 minutes |
| Power Supply | See Chart |
| Dimensions | 79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’) |