Free quotations · Genuine products · Delivery across Thailand and worldwide

Product code: MX-11420
HI97722-11 is a high quality set of calibration standards that allows users to validate and calibrate the cyanuric acid range found in compatible photometers that have a 0 to 80 mg/L (ppm) range. The HI97722-11 includes one sealed A cuvette for zeroing the meter and one B cuvette that is used to validate or calibrate.
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
HI97722-11 is a high quality set of calibration standards that allows users to validate and calibrate the cyanuric acid range found in compatible photometers that have a 0 to 80 mg/L (ppm) range. The HI97722-11 includes one sealed A cuvette for zeroing the meter and one B cuvette that is used to validate or calibrate. The expected reading from the B standard is 20 ±1 mg/L cyanuric acid @ 25°C. The calibration set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment. CAL Check" standards with certificate The HI97722-11 CAL Check"standards are used for calibration and performance verification of HI977xx photometers with the CAL Check" function.
| Cyanuric Acid Range | 0 to 80 mg/L (as CYA) |
|---|---|
| Cyanuric Acid Resolution | 1 mg/L |
| Cyanuric Acid Accuracy | ±1 mg/L ±15% of reading at 25°C |
| Cyanuric Acid Method | adaptation of Turbidimetric Method |
| Photometer/Colorimeter Light Source | LED with 525 nm bandpass filter |
| Photometer/Colorimeter Light Detector | silicon photocell |
| Bandpass Filter Bandwidth | 8 nm |
| Bandpass Filter Wavelength Accuracy | ±1.0 nm |
| Cuvette Type | round 24.6 mm diameter (22 mm inside) |
| GLP | yes |
| Display | 128 x 64 pixel B/W LCD with backlight |
| Logging Memory | 50 readings |
| Battery Type/Life | 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight) |
| Automatic Shut-Off | after 15 minutes of inactivity (30 minutes before a READ measurement) |
| Environment | 0 to 50°C (32 to 122°F); 0 to 100% RH (IP67) |
| Weight | 380 g (13.4 oz.) |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0′′) |
| Ordering Information | HI97722C is supplied with cuvettes (2), caps (2), plastic stopper(2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate |

Hanna
MX-11176
HI9829-14/15 is for premium quality 10 ppm and 100 ppm (mg/L) Nitrate (as N) calibration standards. It is produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with…