Skip to content
ไทย
1/4
Hanna

edge® Multiparameter EC/TDS/Salinity Meter

Product code: MX-11475

edge® is packed with many cutting edge features to ensure accuracy and usability.

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

edge® is packed with many cutting edge features to ensure accuracy and usability.

Digital Electrodes

edge® electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.

Four Ring Probe

The HI2030 edge® EC/TDS/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that has a built in temperature sensor for automatic temperature compensated measurements. The four ring technology allows for a wide range of measurement with a single probe as compared to amperometric two pole probes that have a limited range and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide ) sleeve. Both materials have excellent resistance against many aggressive chemicals.

3.5 mm Probe Input

Plugging an electrode in has never been simpler, no alignments, no broken pins, just connect the 3.5 mm plug and get started.

edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.

Wall Mount

Using the wall mount cradle (included), edge® can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built in connector to power edge® and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.

Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.

edge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.

Two USB Ports

edge® includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge® when the cradle is not available.

Data Logging

edge® allows you to store up to 1000 log records of data. Data can be logged on demand (200 records), on stability (200 records), or at a predefined interval (600 records). The information stored include current reading,date, time and GLP data.

Basic Mode

edge® offers both Basic and Standard Modes. In Basic Mode the edge as an EC meter reduces features to simplify operation. In Basic Mode the meter will only allow for automatic temperature compensation, auto ranging of readings, and automatic cell factor correction while calibrating. The temperature correction coefficient is fixed to 1.9% / oC and interval logging is not available. In Standard mode the user has options to change these features.

Specifications

pH RangepH: -2.000 to 16.000, -2.00 to 16.00 ±1000 mV
pH Resolution0.001 pH, 0.01 pH 0.1 mV
pH Accuracy (@25°C/77°F)±0.01 pH, ±0.002 pH ±0.2 mV
pH CalibrationAutomatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
pH Temperature CompensationAutomatic -5 to 100˚ C (23 to 212˚ F) (using integral temperature sensor)
EC Range0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm
EC Resolution0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration1 Cell Factor calibration 6 standards available: 84, 1413 μS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 μS/cm
TDS Range0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
TDS Resolution0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibrationthrough EC calibration
EC/TDS Temperature CompensationAutomatic -5 to 100 ºC (23 to 212 ºF) NoTC - can be selected to measure absolute conductivity.
Temperature Correction Coefficient0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor0.40 to 0.80 (default value is 0.50)
Salinity Range0.0 to 400.0% NaCl, 0.01 to 42.00 PSU, 0.0 to 80.0 g/L*
Salinity Resolution0.1% NaCl, 0.01 PSU, 0.01 g/L
Salinity Accuracy±1% of reading
Salinity Calibration1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)
Salinity Temperature Compensation0 to 40 g/L (with 1 g/L resolution)
Sodium Chloride Range0.0 to 400.0% NaCl
Sodium Chloride Resolution0.1% NaCl
Sodium Chloride Accuracy±1% of reading
Sodium Chloride Calibration1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)
DO Range0.00 to 45.00 ppm (mg/L) 0.0 to 300.0% 0.0 to 50.0 °C (32.0 to 122.0 °F)**
DO Accuracy (@25˚C/77˚F)±1.5% of reading or ±1 digit
DO Resolution0.01 ppm (mg/L) 0.1% saturation
DO CalibrationOne or two points at 0% (HI 7040) and 100% (water saturated air)
DO Temperature Compensation0.0 to 50.0 ˚C (32.0 to 122 ˚F)
Salinity Compensation0 to 40 g/L, 1 g/L
DO Altitude Compensation-500 to 4000 m (with 100 m resolution)
Temperature Range-20.0 to 120.0 ˚C, -4.0 to 248.0 °F
Temperature Resolution0.1 °C, 0.1 °F
Temperature Accuracy±0.5 °C, ±1.0 °F
pH ElectrodeHI11310 digital double junction, refillable with 3.5M KCl electrolyte solution pH electrode, built in temperature sensor, and 3.5 mm connector.ᵻ
EC/TDS ProbeHI763100 EC/temperature probe
DO ProbeHI764080 DO/temperature probeᵻ
Power Supply5 VDC adapter (included)
Environment0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions202 x 140 x 12.7mm (8in. x 5.5in. x 0.5in.)
Weight250 g (8.82 oz)
Ordering InformationHI2030 EC kit includes: HI763100 Conductivity probe, 4 sachets of 1413 μS/cm conductivity standard, 2 sachets of 5000 μS/cm conductivity standard, 2 sachets of 12880 μS/cm conductivity standard, 2 sachets general purpose rinse solution, USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, quality certificate and instruction manual.
Special Notes‡ absolute conductivity *temperature limits will be reduced to actual probe/sensor limits ** with temperature compensation function disabled ᵻAvailable for purchase separately
Warranty2 years