HI7091L – Reducing Pretreatment Solution, 500 ml

Product code: MX-12288

ORP standard solutions allow you to test the precision of ORP electrodes. For example, by immersing the electrode in HI 7020 solution, you should read within the 200 to 275 mV range (@20°C/68°F). If the reading is outside the indicated interval, clean and condition your ORP electrode in HANNA® pretreatment solution.

Prices are quoted, not listed.

Ask for a quotation and we’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE

Request a quotation for this item

For a number outside Thailand, start with + and the country code.

A phone number or an email address is enough for us to reply to this request. Privacy Policy

For several items, add each one to a single request.

1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

ORP (Oxidation Reduction Potential) electrodes are used to measure a chemical reaction in which one species is being oxidized and another is being reduced. The loss of electrons by an element or compound is known as oxidation reaction while the gaining of electrons by an element or compound is known as reduction reaction. For example, plating companies that have hexavalent chromium (Cr6+) in their wastewater must reduce it to a safer trivalent chromium (Cr3+) form. This reduction reaction occurs in the presence of a strong reductant such as sodium metabisulfite. The addition of the reductant must be measured with an ORP electrode to ensure that there is an adequate reducing potential. Using the HI7091L reducing pretreatment solution prior to taking a measurement provides for a faster response time in a reducing environment. To use, soak the ORP electrode in the pretreatment solution for 15 minutes prior to use. As a general rule, if the mV reading corresponding to the pH measurement is lower than the value in the table below the reducing pretreatment solution (HI7091) is used. If the mV reading corresponding to the pH measurement is higher than the value in the table below then the oxidizing pretreatment (HI7092) should be used.

How quotation ordering works

See the full ordering guide
  1. 01

    Send your requirements

    Send the details you have, even if your list is incomplete. You can also browse the catalog to choose items.

  2. 02

    We check and quote

    We check the details, source the items and prepare your quotation with pricing and delivery information.

  3. 03

    Review and order

    Review the items, prices and delivery details before confirming your order. We flag any item that still needs confirmation.