Free quotations · Genuine products · Delivery across Thailand and worldwide

Product code: MX-12337
Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking-water. Fluoride has beneficial effects on teeth at low concentrations in drinking-water, but excessive exposure to fluoride in drinking-water, or in combination with exposure to fluoride from other…
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
The HI739 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure fluoride. Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects. Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth, it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities. A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride. Designed as a more accurate alternative to chemical test kits, the HI739 provides quick, accurate results in a few easy steps.
| Range | 0.0 to 20.0 ppm |
|---|---|
| Resolution | 0.1 ppm |
| Accuracy @ 25°C | ±0.5 ppm ± 5% of reading |
| Light Source | LED @ 575 nm |
| Light Detector | silicon photocell |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Battery Type | (1) 1.5V AAA |
| Auto-off | after two minutes of non-use and ten seconds after reading |
| Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) |
| Weight | 64 g (2.25 oz.) |
| Method | adaptation of SPADNS method |

Hanna
MX-11176
HI9829-14/15 is for premium quality 10 ppm and 100 ppm (mg/L) Nitrate (as N) calibration standards. It is produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with…