The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference…
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI8061L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings. FDA compliant bottle Light blocking bottle to prevent degradation by UV light Airtight bottle with tamper-proof seal Ensures quality and freshness of solution Each bottle marked with lot number and expiration date Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle. Hanna offers a complete line of cleaning solutions engineered for specific applications.

Hanna
MX-12487
HI8087L is a premium quality 0.23 g/L Na+ (sodium) standard solution produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers.

Hanna
MX-12475
H8031L is a premium quality 1,413 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-11174
The HI801 iris spectrophotometer is designed to work with five different cuvettes: 22 mm round 16 mm round 13 mm vial 10 mm square 50 mm rectangular The meter is supplied with three cuvette adapters: adapter for 16 mm cuvette adapter for 10 mm square cuvette adapter for 13 mm vial Note: The 22 mm round and 50 mm…

Hanna
MX-12478
H8035L is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.