Free quotations · Genuine products · Delivery across Thailand and worldwide

Product code: MX-12532
The HI84529U-01 uses methods based on AOAC International and Standard Methods for the Examination of Dairy Products. Both of these methods report titratable acidity as % lactic acid and a conversion factor is used to convert the results to the other available units.
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
The HI84529U-01 uses methods based on AOAC International and Standard Methods for the Examination of Dairy Products. Both of these methods report titratable acidity as % lactic acid and a conversion factor is used to convert the results to the other available units. The HI84529U-01 can be customized to meet the needs of any dairy analysis lab. Samples can be titrated by weight or volume, diluted or non-diluted (low range only) and titrated to a fixed pH endpoint that can be adjusted by the user. The HI84529U-01 offers three different methods depending on the expected range and the weight of sample used. Select low range 50 to titrate a 50 mL or 50 g undiluted sample. The other titration options are low range 20 and high range 20 to titrate 20 mL or 20 g samples that are diluted twice their volume with deionized or distilled water. There are two fundamentally different measurements of dairy products: titratable acidity and pH. pH is a measurement of hydrogen ion concentration while titratable acidity is the neutralizing capacity of a dairy product with NaOH. An increase in acidity can be caused by bacteria formation. Monitoring acidity is a way of determining the quality and freshness of dairy products. Acidity is determined by a pH endpoint titration using NaOH (sodium hydroxide) and is defined as the consumption necessary to shift the pH value from 6.6 (corresponding to fresh milk) to a pre-determined pH value. When using phenolphthalein as an indicator, a faint pink color change occurs at pH 8.3. Titratable acidity is expressed in a variety of units based on the titration method performed. Each method varies in sample size and strength of NaOH used for the titration. % Lactic Acid (%l.a.): Determined by taking a 20 mL or 20 g sample and diluting with twice its volume with deionized or distilled water. The sample is then titrated with 0.1 M NaOH to a phenolphthalein endpoint. Degree Soxhlet Henkel (°SH): Determined by titrating a 50 mL sample with 0.1 M NaOH to a phenolphthalein endpoint. Degree Dornic (°D): Determined by titrating a 100 mL sample with N/9 NaOH to a phenolphthalein endpoint. Degree Thrner: Determined by taking a 10 mL sample and diluting with twice its volume with deionized or distilled water. The sample is then titrated with 0.1 M NaOH to a phenolphthalein endpoint. Knowing the relationship between sample weight or volume and strength of titrant it is possible to convert the reading obtained from one method to another. Below is a table with the factors preprogrammed in the HI84529U-01 for converting between various units of measure. From: To: Divide By: %l.a.
| Range | Low Range: %l.a.: 0.01 to 0.20 °SH: 0.4 to 8.9 °D: 1.0 to 20.0 °Th: 1.1 to 22.2 High Range: %l.a.: 0.1 to 2.0 °SH: 4.4 to 88.9 °D: 10 to 200 °Th: 11.1 to 222.2 |
|---|---|
| Resolution | Low Range: %I.a.: 0.01 °SH: 0.1 °D: 0.1 °Th: 0.1 High Range: %I.a.: 0.1 °SH: 0.1 °D: 1 °Th: 0.1 |
| Accuracy (@25ºC/77ºF) | Low Range: ± 0.01 %l.a. High Range: ± 0.1 %l.a. |
| Sample Volume | LR 20: 20 mL or 20 g LR 50: 50 mL or 50 g HR 20: 20 mL or 20 g |
| Methods | acid base titration |
| Principle | endpoint titration |
| Pump Speed | 10 mL/min |
| Stirring Speed | 800 rpm |
| pH Range | -2.0 to 16.0 pH -2.00 to 16.00 pH |
| pH Resolution | 0.1 pH / 0.01 pH |
| pH Accuracy (@25ºC/77ºF) | ±0.01 pH |
| pH Calibration | one, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01) |
| Temperature Compensation | manual or automatic |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy (@25ºC/77ºF) | ±1.0 mV |
| Temperature Range | -20.0 to 120.0°C -4.0 to 248.0°F 253.2 to 393.2 K |
| Temperature Resolution | 0.1°C 0.1°F 0.1K |
| Temperature Accuracy (@25ºC/77ºF) | ±0.4°C ±0.8°F ±0.4 K |
| Logging Data | up to 400 ( 200 titrations, 200 pH/mV readings) |
| Electrode | FC260B pH electrode with 1 m (3.3') cable (included), HI5315 reference probe with 1 m (3.3') cable (included) |
| Temperature Probe | HI7662-M stainless steel temperature probe with 1 m (3.3') cable (included) |
| Environment | 0 to 50°C (32 to 122°F) RH max 95% non-condensing |
| Power Supply | 12 VDC adapter (included) |
| Dimensions | 235 x 200 x 150 mm (9.2 x 7.9 x 5.9in.) |
| Weight | 1.9 kg (67.0 oz.) |
| Warranty | 2 years |

Hanna
MX-12343
The HI740236 replacement 5 mL plastic syringe allows for reliable titrant delivery and dosing for a variety of titrations. The syringe is easily replaced and can be connected in a matter of minutes.

Hanna
MX-12522
The HI84500-61 alkaline reagent is necessary for the analysis of total sulfur dioxide. The alkaline reagent raises the pH and liberates bound sulfur dioxide. This pH adjustment ensures that all of the free and bound sulfur dioxide is accounted for to give an accurate measurement of total sulfur dioxide.

Hanna
MX-11235
Our Aspiration Tube Set (HI900570) is compatible with our Karl Fischer Titration Systems (HI903 and HI933). The tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve. This includes PTFE titrant tubing, blue tubing protection, and the tube lock.