ISO 7027 Compliant Benchtop Turbidity Meter

Product code: MX-12568

The HI88713 Precision ISO Turbidity Benchtop Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges.

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

The HI88713 Precision ISO Turbidity Benchtop Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.

Features at-a-glance

Four Measurement Modes - The HI88713 features four options for turbidity measurement: FNU (Formazin Nephelometric Units), FAU (Formazin Attenuation Units), and NTU (Nephelometric Turbidity Units) ratio and non-ratio mode. Turbidity ranges for each mode are 0.00 to 1000 FNU, 10.0 to 4000 FAU, 0.00 to 4000 NTU (ratio mode), and 0.00 to 1000 NTU (non-ratio mode).Multiple Turbidity Units of Measure - Turbidity can be read as Formazin Nephelometric Units (FNU), Formazin Attenuation Units (FAU), European Brewing Convention units (EBC), and Nephelometric Turbidity Units (NTU).ISO Compliant - The HI88713 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source.Calibration - The HI88713 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two, three, four, or five-point turbidity calibration can be performed by using the supplied (<0.10, 15, 100, 750 FNU, and 2000 NTU) standards. Calibration points can be modified if user-prepared standards are used.AMCO AEPA-1 Primary Turbidity Standard - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.GLP Data - The HI88713 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.Data Logging - Up to 200 measurements can be stored in the internal memory and recalled at any time.Data Transfer - For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the USB port and the HI92000 software.Tutorial Mode - The unique tutorial mode provides additional information to help the user during measurements. When enabled, the instrument displays explanations and a confirmation button when a preparation or other operation has to be performed.Contextual Help - Contextual help is always available through a dedicated HELP button. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.Backlit Graphic LCD Display - A graphic LCD display provides an easy to understand, user-friendly interface. All messages are in plain text making them easy to read.

Turbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water, significant evidence exists that controlling turbidity is a competent safeguard against pathogens. In natural water, turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity. Currently, the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.

Specifications

FNU Range0.00 to 9.99 10.0 to 99.9 100 to 1000 FNU
FNU Resolution0.01 0.1 1 FNU
FNU Accuracy±2% of reading plus straylight
FAU Range10.0 to 99.9 100 to 4000 FAU
FAU Resolution0.1 1 FAU
FAU Accuracy±10% of reading
NTU ratio Range0.00 to 9.99 10.0 to 99.9 100 to 4000 NTU 0.00 to 9.99 10.0 to 99.9 100 to 980 EBC
NTU ratio Resolution0.01 0.1 1 NTU 0.01 0.1 1 EBC
NTU ratio Accuracy±2% of reading plus straylight ±5% of reading above 1000 NTU
NTU non ratio Range0.00 to 9.99 10.0 to 99.9 100 to 1000 NTU 0.00 to 9.99 10.0 to 99.9 100 to 245 EBC
NTU non ratio Resolution0.01 0.1 1 NTU 0.01 0.1 1 EBC
NTU non ratio Accuracy±2% of reading plus straylight
Range SelectionAutomatic
Turbidity Repeatability±1% of reading or straylight, whichever is greater
Stray Light&lt 0.1 NTU (0.05 EBC)
Turbidity Light DetectorSilicon Photocell
Turbidity MethodISO 7027 Method
Measuring modeNormal, Average, Continuous.
Turbidity Standards&lt0.1, 15, 100, 750 FNU and 2000 NTU
CalibrationTwo, three, four or five-point calibration
Light SourceIR LED
Lamp LifeInstrument life
Display40 x 70mm graphic LCD (64x128 pixels) with backlight
LOG Memory200 records
Serial InterfaceUSB
Environment0°C (32°F) to 50°C (122°F) max 95% RH non-condensing
Power Supply12 Vdc power input
Dimensions230 x 200 x 145 mm (9 x 7.9 x 5.7in.) L x W x H
Weight2.5 Kg (88 oz.)
Warranty2 years