Meter with or without GPS Built-in GPS Receiver 12 channel GPS receiver and antenna Tracks location using satellites to within 30 feet Latitude and longitude recorded with readings Location naming for GPS coordinates Distance from current location to the stored location Hi929829 multiparameter water quality meter…
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Meter with or without GPS Built-in GPS Receiver 12 channel GPS receiver and antenna Tracks location using satellites to within 30 feet Latitude and longitude recorded with readings Location naming for GPS coordinates Distance from current location to the stored location Hi929829 multiparameter water quality meter software supplied integrates data collected with Google™ maps Measurement readings including GPS coordinates Date and time Named locations and remarks Sample number Google™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™. Two probes to choose from (Basic or Logging) The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default, the HI9829 and the corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor. HI7609829 Basic Probe Digital probe that is less than 2 inches in diameter 3 color-coded sensor inputs IP68 rating for continuous immersion in water Multistrand –multiconductor cable rated for 150 lbs (intermittent use) Available with 4, 10, or 20-meter cable Weighted shield protects all sensors HI7629829 Autonomously Logging Probe Same as basic probe but with logging capability Logs data independent of HI9829 meter Operates on 4 "AAin. batteries for up to 70 days* Stores up to 140,000 single parameter readings or 35,000 for all parameters Logs data from 1 second to 3 hours Choose to be supplied with EC or EC/Turbidity sensor Supplied with USB cable for direct connection to Window's compatible PC *All channels logging at 10-minute intervals with no averaging Waterproof Protection – The water quality meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water. Backlit Dot Matrix LCD Display – The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface. Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup and logging of data. The interface is intuitive for any user's level of experience. Dedicated Help Key – Contextual help is always available through a dedicated "HELPin. key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.
| pH Accuracy @ 25°C / 77°F | ± 0.02 pH |
|---|---|
| pH Calibration | Automatic at 1, 2 or 3 points with automatic recognition of 5 standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer |
| mV Range | ± 600.0 mV |
| mV Accuracy | ± 0.5 mV |
| ORP Range | ± 2000.0 mV |
| ORP Accuracy (@25°C/77°F) | ± 1.0 mV |
| ORP Calibration | Automatic at 1 custom point (relative mV) |
| Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
| Temperature Resolution | 0.01 °C, 0.01 °F, 0.01 K, |
| Temperature Accuracy @ 25°C / 77°F | ± 0.15 °C, ± 0.27 °F, ± 0.15 K |
| Temperature Calibration | Automatic at 1 custom point |
| EC Resolution | Manual: 1 µS/cm |
| EC Accuracy @25°C/77°F | ± 1% of reading or ± 1 µS/cm whichever is greater |
| EC Calibration | Automatic 1 point, with 6 standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Resolution | Manual: 1 ppm (mg/L) |
| TDS Accuracy @ 25°C / 77°F | ± 1% of reading or ± 1 ppm (mg/L), whichever is greater |
| DO Range | 0.0 to 500.0% |
| DO Resolution | 0.1% |
| DO Accuracy (@25°C/77°F) | 0.0 to 300.0% saturation: ±1.5% of reading or ± 1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ± 1.5% of reading or ± 0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% satura |
| DO Calibration | Automatic 1 or 2 points at 0, 100% or 1 custom point |

Hanna
MX-11176
HI9829-14/15 is for premium quality 10 ppm and 100 ppm (mg/L) Nitrate (as N) calibration standards. It is produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with…