The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and…

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

HI9829-10 is a premium quality 10 ppm (mg/L) Ammonium Nitrogen calibration standard. It is produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Convenience of individual packaging Ideal for field use due to portability Every sachet is as fresh as the day it was packaged pH and ionic strength stabilized Each sachet marked with lot number and expiration date. Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.

Specifications

pH Range0.00 to 14.00 pH
pH Resolution0.01 pH
pH Accuracy±0.02 pH
pH Calibrationautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
mV Range±600.0 mV
mV Resolution0.1 mV
mV Accuracy±0.5 mV
ORP Range±2000 mV
ORP Resolution0.1 mV
ORP Accuracy±1.0 mV
ORP Calibrationautomatic at one custom point (relative mV)
EC Range0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Accuracy±1% of reading or ±1 μS/cm whichever is greater
EC Calibrationautomatic single point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Accuracy±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibrationbased on conductivity or salinity calibration
Resistivity Range0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity Resolutiondependent on resistivity reading
Resistivity Calibrationbased on conductivity calibration
Salinity Range0.00 to 70.00 PSU
Salinity Resolution0.01 PSU
Salinity Accuracy±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibrationbased on conductivity calibration
Seawater σ Range0.0 to 50.0 σt, σ0, σ15
Seawater σ Resolution0.1 σt, σ0, σ15
Seawater σ Accuracy±1 σt, σ0, σ15
Seawater σ Calibrationbased on conductivity or salinity calibration
Ammonium-Nitrogen Range0.02 to 200.0 ppm Am (as NH4 +-N)
Ammonium-Nitrogen Resolution0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Ammonium-Nitrogen Accuracy±5 % reading or 2 ppm
Ammonium-Nitrogen Calibration1 or 2 point, 10 ppm and 100 ppm
Chloride Range0.6 to 200.0 ppm Cl (as Cl- )
Chloride Resolution0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Chloride Accuracy±5 % of reading or 2 ppm
Chloride Calibration1 or 2 point, 10 ppm and 100 ppm
Nitrate-Nitrogen Range0.62 to 200.0 ppm Ni (as NO3 – -N)
Nitrate-Nitrogen Resolution0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
Nitrate-Nitrogen Accuracy±5 % of reading or 2 ppm
Nitrate-Nitrogen Calibration1 or 2 point, 10 ppm and 100 ppm
Turbidity Range0.0 to 99.9 FNU; 100 to 1000 FNU
Turbidity Resolution0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
Turbidity Accuracy±0.3 FNU or ±2 % of reading, whichever is greater
Turbidity CalibrationAutomatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
DO Range0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
DO Resolution0.1%; 0.01 ppm (mg/L)
DO Accuracy0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
DO Calibrationautomatic one or two points at 0 and 100% or one custom point
Atmospheric Pressure Range450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy±3 mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibrationautomatic at one custom point
Temperature Range-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
Temperature Resolution0.01 K, 0.01 °C, 0.01 °F
Temperature Accuracy±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibrationautomatic at one custom point
Temperature Compensationautomatic from -5 to 55 °C (23 to 131 °F)
Logging Memory44,000 records (continuous logging or log-on-demand of all parameters)
Logging Intervalone second to three hours
PC ConnectivityUSB (with HI 929829 software)
Battery Type/Life1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration
Waterproof ProtectionIP67
Environment0 to 50°C (32 to 122°F); RH max 100%
Dimensions221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
Weight750 g (26.5 oz.)
GPS12 channel receiver 10 m (30 ft) accuracy