The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and…
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
HI9829-10 is a premium quality 10 ppm (mg/L) Ammonium Nitrogen calibration standard. It is produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Convenience of individual packaging Ideal for field use due to portability Every sachet is as fresh as the day it was packaged pH and ionic strength stabilized Each sachet marked with lot number and expiration date. Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.
| pH Range | 0.00 to 14.00 pH |
|---|---|
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
| mV Range | ±600.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.5 mV |
| ORP Range | ±2000 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±1.0 mV |
| ORP Calibration | automatic at one custom point (relative mV) |
| EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
| EC Accuracy | ±1% of reading or ±1 μS/cm whichever is greater |
| EC Calibration | automatic single point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
| TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
| TDS Calibration | based on conductivity or salinity calibration |
| Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
| Resistivity Resolution | dependent on resistivity reading |
| Resistivity Calibration | based on conductivity calibration |
| Salinity Range | 0.00 to 70.00 PSU |
| Salinity Resolution | 0.01 PSU |
| Salinity Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
| Salinity Calibration | based on conductivity calibration |
| Seawater σ Range | 0.0 to 50.0 σt, σ0, σ15 |
| Seawater σ Resolution | 0.1 σt, σ0, σ15 |
| Seawater σ Accuracy | ±1 σt, σ0, σ15 |
| Seawater σ Calibration | based on conductivity or salinity calibration |
| Ammonium-Nitrogen Range | 0.02 to 200.0 ppm Am (as NH4 +-N) |
| Ammonium-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Ammonium-Nitrogen Accuracy | ±5 % reading or 2 ppm |
| Ammonium-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) |
| Chloride Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Chloride Accuracy | ±5 % of reading or 2 ppm |
| Chloride Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Nitrate-Nitrogen Range | 0.62 to 200.0 ppm Ni (as NO3 – -N) |
| Nitrate-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
| Nitrate-Nitrogen Accuracy | ±5 % of reading or 2 ppm |
| Nitrate-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
| Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
| Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater |
| Turbidity Calibration | Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
| DO Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
| DO Resolution | 0.1%; 0.01 ppm (mg/L) |
| DO Accuracy | 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading |
| DO Calibration | automatic one or two points at 0 and 100% or one custom point |
| Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration |
| Atmospheric Pressure Calibration | automatic at one custom point |
| Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
| Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
| Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
| Temperature Calibration | automatic at one custom point |
| Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
| Logging Memory | 44,000 records (continuous logging or log-on-demand of all parameters) |
| Logging Interval | one second to three hours |
| PC Connectivity | USB (with HI 929829 software) |
| Battery Type/Life | 1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration |
| Waterproof Protection | IP67 |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
| Weight | 750 g (26.5 oz.) |
| GPS | 12 channel receiver 10 m (30 ft) accuracy |

Hanna
MX-11176
HI9829-14/15 is for premium quality 10 ppm and 100 ppm (mg/L) Nitrate (as N) calibration standards. It is produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with…