Free quotations · Genuine products · Delivery across Thailand and worldwide

Product code: MX-12955
Accuracy capabilities Equipped with a dosing pump that offers an unmatched 40,000 step accuracy Save and store up to 100 titration methods (either user-defined or standard). Customize methods to fit specific application needs or testing requirements.
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Accuracy capabilities Equipped with a dosing pump that offers an unmatched 40,000 step accuracy Save and store up to 100 titration methods (either user-defined or standard). Customize methods to fit specific application needs or testing requirements. Easily program this titrator with standard methods that are in accordance with affiliations like ISO, ASTM, AOAC, AOCS, EPA and more Operators can program this titrator unit with notification reminders for when to standardize the titrant This titrator automatically calculates the average titer value and users can update the nominal concentration in the sample methods with the press of a button Track progress in real-time. All important information is shown on the titrator's large LCD screen. Use the live titration curve during analysis to quickly recognize patterns and spot potential problems Achieve high speed analysis without sacrificing accuracy with dynamic titrant dosing. This occurs by adjusting the volume of titrant dosed according to the mV response from the titrator reaction Get more accurate measurements with automatic drift rate compensation. This corrects the titration calculation to account for the effects of any moisture that may enter the cell Choose the endpoint termination criteria based on mV stability times or drift rates with the dual platinum pin electrode Maintain data quality with the titration results averaging feature. Ideal for those operators who consistently run replicates of samples. The successive results from a titration method are averaged along with the standard deviation Attain a reliable starting baseline with the multistage analysis. This works well for users that test multiple sample types with different methods for each Durability and design details Manufactured to stand up to the harsh solvents and reagents used during titrations Made with tough, chemically resistant materials including a strong casing as well as PFTE tubing with glass and stainless-steel components Convenient-size, fits perfectly into any lab space Simple to set up and user-friendly. Perfect for labs and businesses that have multiple personnel shift changes throughout the day Intuitive screens and menus help operators navigate this titrator unit easily without getting lost in a nest of information Safe and important operation features Introducing a solid or liquid sample to the titration vessel is simple and straightforward.
| Range | 100 ppm to 100% |
|---|---|
| Resolution | 1 ppm to 0.0001% |
| Result Units | %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc |
| Sample Type | liquid or solid |
| Pre-Titration Conditioning | automatic |
| Background Drift Correction | automatic or user-selectable value |
| Endpoint Criteria | fixed mV persistence, relative drift stop or absolute drift stop |
| Dosing | dynamic with optional pre-dispensing |
| Result Statistics | mean, standard deviation |
| Dosing Pump Resolution | 1/40000 of the burette volume (0.125 μL per dose) |
| Dosing Pump Accuracy | ± 0.1% of full burette volume |
| Syringe | 5 mL precision ground with PTFE plunger |
| Valve | motor-driven 3-way, PTFE liquid contact material |
| Tubing | PTFE with light block and thermal jacketing |
| Dispensing Tip | glass, fixed position, anti-diffusion |
| Titration Vessel | conical with operating volume between 50-150 mL |
| Solvent Handling System | sealed system, integrated diaphragm air pump |
| Sensor Type | HI76320 dual platinum pin polarization electrode |
| Sensor Connection | BNC |
| Polarization Current | 1, 2, 5, 10, 15, 20, 30 or 40 μA |
| Voltage Range | 2 mV to 1000 mV |
| Voltage Resolution | 0.1 mV |
| Accuracy | ± 0.1% |
| Programmable Stirrer | magnetic, electronic regulated, digital stirrer 200 to 2000 rpm resolution 100 rpm |
| Display | 5.7in. (320 x 240 pixel) color LCD |
| Methods | up to 100 methods (standard and user-defined) |
| Logging Data | up to 100 complete titration reports and drift rate reports can be stored |
| Peripherals (Rear) | PC Connection, USB Flash Drive, Analytical Balance, Printer, External PC Keyboard |
| GLP Conformity | Good Laboratory Practice and instrument data storage and printing |
| Languages | English, Portuguese. Spanish, and French |
| Enclosure Material | ABS, PC and stainless steel |
| Keypad | polyester |
| Operating Environment | 10 to 40°C (50 to 104°F), up to 80% RH |
| Storage Environment | -20 to 70°C (-4 to 158°F), up to 95% RH |
| Power Supply | 100-240 Vac, 50/60 Hz |
| Dimensions | 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 ) |
| Weight | approximately 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors |
| Warranty | 2 years |

Hanna
MX-12343
The HI740236 replacement 5 mL plastic syringe allows for reliable titrant delivery and dosing for a variety of titrations. The syringe is easily replaced and can be connected in a matter of minutes.

Hanna
MX-12522
The HI84500-61 alkaline reagent is necessary for the analysis of total sulfur dioxide. The alkaline reagent raises the pH and liberates bound sulfur dioxide. This pH adjustment ensures that all of the free and bound sulfur dioxide is accounted for to give an accurate measurement of total sulfur dioxide.

Hanna
MX-11235
Our Aspiration Tube Set (HI900570) is compatible with our Karl Fischer Titration Systems (HI903 and HI933). The tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve. This includes PTFE titrant tubing, blue tubing protection, and the tube lock.