Skip to content
ไทย
1/2
Hanna

Foodcare pH Electrode for Meat Products with Quick Connect DIN Connector

Product code: MX-11510

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

Used in:Food & beverage

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC2323 uses low temperature (LT) glass, conical bulb, food-grade PVDF body, and an open junction with viscolene gel electrolyte.

Low-Temperature Glass Formulation

The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general-purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter. The FC2323 is suitable to use with samples that measure from 0 to 50°C.

Conical Glass Tip

The conical-shaped tip design allows for penetration into solids, semi-solids, and emulsions for the direct measurement of pH in food products.

Stainless Steel Blade

An optional stainless steel blade is attached to the probe for easy meat penetration, even in frozen samples. Slicing into the meat will allow for the pH glass and reference junction to be in contact with the sample, allowing for a direct pH measurement without extensive sample preparation. The FC098 (20 mm; 0.75in.) and the FC099 (35mm; 1.38in.) are a set of two stainless steel penetration blades to be used with the FC2323.

PVDF Body

Polyvinylidene fluoride (PVDF) is a food-grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength, and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.

Open Junction Reference

Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.

Quick Connect DIN Connector

The FC2323 uses a Quick Connect DIN connector that makes attaching and removing the probe simple and easy. This type of connector is proprietary to the meter. See specifications table for compatible meters.

Specifications

DescriptionpH electrode
Referencesingle, Ag/AgCl
Junction / Flow Rateopen
Electrolyteviscolene
Max Pressure0.1 bar
RangepH: 0 to 12
Recommended Operating Temperature0 to 50°C (32 to 122°F) - LT
Tip / Shapeconic (6 x 10 mm)
Body Length36 mm / 164 mm
Temperature Sensoryes
Amplifieryes
Body MaterialPVDF
Cable7-pole 1 m (3.3')
Recommended Usemeat
ConnectionQuick Connect DIN**
Special Note* Recommended for use with HI98163 and HI99163 pH meters