Skip to content
ไทย

Electrodes & Probes

Replacement pH electrodes and temperature probes: Ohaus ST310, ST320 and ST350 3-in-1 electrodes, Mettler Toledo LE438, Eutech ECFC and ECFG glass- and plastic-body electrodes, Bante refillables, and Testo immersion, needle and fiberglass probes with TopSafe cases. Electrolyte and storage solutions are on the Consumables & Reagents shelf. Tell us your meter model and we will match the connector — quotations are free.

Electrode selection guide

Check the connector first, then the sample

An electrode is chosen against two unrelated things: the meter it plugs into, and the sample it sits in. The connector decides whether it works at all. The junction and body decide how long it lasts and whether the reading can be trusted.

See the checklist and buying questions

320 products · page 1 of 7

0516 0221 TopSafe Protective Case

Testo

0516 0221 TopSafe Protective Case

MX-10300

0516 0224 TopSafe Protective Case

Testo

0516 0224 TopSafe Protective Case

MX-10340

0602 0645 Fiberglass Probe

Testo

0602 0645 Fiberglass Probe

MX-10297

0602 1293 Immersion Probe

Testo

0602 1293 Immersion Probe

MX-10298

0613 1212 Immersion Probe

Testo

0613 1212 Immersion Probe

MX-10299

2-Ring Cell Conductivity and Temperature Industrial Smart Probe

Hanna

2-Ring Cell Conductivity and Temperature Industrial Smart Probe

MX-11185

30973298 Probe Holder Kit-1

Ohaus

30973298 Probe Holder Kit-1

MX-10406

4-ring conductivity, platinum on glass, process smart probe

Hanna

4-ring conductivity, platinum on glass, process smart probe

MX-11190

3m Adapter Cable for Immersion In-line Electrodes

Hanna

Adapter Cable for Immersion In-line Electrodes

2 variants: 3m · 5m

Choose a variant
AmpHel® Flat-tip Gold-Type ORP Electrode - General Purpose

Hanna

AmpHel® Flat-tip Gold-Type ORP Electrode - General Purpose

MX-11221

AmpHel® ORP Electrodes with Internal Battery - General Purpose, 5m Cable

Hanna

AmpHel® ORP Electrodes with Internal Battery - General Purpose, 5m Cable

MX-11227

AmpHel® pH Electrode with Replaceable Battery - General Purpose, 5m

Hanna

AmpHel® pH Electrode with Replaceable Battery - General Purpose, 5m

MX-11226

AmpHel® pH Electrode with Replaceable Battery - High Temperature

Hanna

AmpHel® pH Electrode with Replaceable Battery - High Temperature

MX-11230

AmpHel® pH Electrodes with Internal Battery

Hanna

AmpHel® pH Electrodes with Internal Battery

MX-11220

Blue Shockproof Rubber Boot for Fixed Probes

Hanna

Blue Shockproof Rubber Boot for Fixed Probes

MX-11269

Blue Shockproof Rubber Boot for Interchangeable Probes

Hanna

Blue Shockproof Rubber Boot for Interchangeable Probes

MX-11270

Built-in temperature sensor

Hanna

Built-in temperature sensor

MX-11679

Combination Glass-body pH Electrode - Low Temperature (LT), T-type Connector

Hanna

Combination Glass-body pH Electrode - Low Temperature (LT), T-type Connector

MX-11378

Combination Glass-body pH Electrode - Low Temperature, T Connector

Hanna

Combination Glass-body pH Electrode - Low Temperature, T Connector

MX-11373

Combination Glass-body pH Electrode - Low Temperature, T-type Connector

Hanna

Combination Glass-body pH Electrode - Low Temperature, T-type Connector

MX-11377

Combination Glass-body pH Electrode - T-type Connector

Hanna

Combination Glass-body pH Electrode - T-type Connector

MX-11376

Combination PEI-body pH Electrode

Hanna

Combination PEI-body pH Electrode

MX-11380

Combination PEI-body pH Electrode - General Purpose, T-type Connector

Hanna

Combination PEI-body pH Electrode - General Purpose, T-type Connector

MX-11381

Combination PEI-body pH Electrode - High Temperature, T-type Connector

Hanna

Combination PEI-body pH Electrode - High Temperature, T-type Connector

MX-11382

Conductivity and Turbidity Sensor for the Portable Multiparameter HI98594

Hanna

Conductivity and Turbidity Sensor for the Portable Multiparameter HI98594

MX-11388

Copper Half-Cell Ion Selective Electrode (ISE)

Hanna

Copper Half-Cell Ion Selective Electrode (ISE)

MX-11913

Desiccant Cartridge for the Generator Electrode on the HI904

Hanna

Desiccant Cartridge for the Generator Electrode on the HI904

MX-11426

Digital Conductivity Probe for HI98199

Hanna

Digital Conductivity Probe for HI98199

MX-11431

Digital DO/Temperature Electrode

Hanna

Digital DO/Temperature Electrode

MX-12399

Digital Flat Tip pH Electrode for Food Surfaces

Hanna

Digital Flat Tip pH Electrode for Food Surfaces

MX-11432

Digital Galvanic Dissolved Oxygen Probe for HI98199

Hanna

Digital Galvanic Dissolved Oxygen Probe for HI98199

MX-11433

Digital Gel Filled PEI Body ORP Electrode for Field Applications

Hanna

Digital Gel Filled PEI Body ORP Electrode for Field Applications

MX-11434

Digital Glass Body Foodcare pH Electrode for Dairy Products

Hanna

Digital Glass Body Foodcare pH Electrode for Dairy Products

MX-11502

Digital Glass Body ORP Electrode for General Purpose

Hanna

Digital Glass Body ORP Electrode for General Purpose

MX-11435

Digital Glass Body pH Electrode with Clogging Prevention System (CPS)

Hanna

Digital Glass Body pH Electrode with Clogging Prevention System (CPS)

MX-11651

Digital pH/Temp electrode for HI98199

Hanna

Digital pH/Temp electrode for HI98199

MX-11436

Digital PVDF Body Foodcare pH Electrode for Dairy Products

Hanna

Digital PVDF Body Foodcare pH Electrode for Dairy Products

MX-11499

Digital PVDF Body Foodcare pH Electrode for Meat Products

Hanna

Digital PVDF Body Foodcare pH Electrode for Meat Products

MX-11509

Direct Soil and Soilless Media pH electrode for use with HI9814

Hanna

Direct Soil and Soilless Media pH electrode for use with HI9814

MX-13065

Dual Platinum Pin Electrode

Hanna

Dual Platinum Pin Electrode

MX-11451

Dual Platinum Pin Electrode for HI904

Hanna

Dual Platinum Pin Electrode for HI904

MX-11450

E201-BNC Refillable pH Electrode

Bante

E201-BNC Refillable pH Electrode

MX-10683

EC Probe for use with HI2315

Hanna

EC Probe for use with HI2315

MX-11464

EC/Resistivity Probe for HI98197

Hanna

EC/Resistivity Probe for HI98197

MX-11465

EC/TDS Probe

Hanna

EC/TDS Probe

MX-11471

EC/TDS Probe for HI993xx

Hanna

EC/TDS Probe for HI993xx

MX-11469

Electrode selection guide

Five decisions before ordering an electrode

01

Meter and connector

State the meter model and the connector — BNC, DIN, Quick Connect DIN, RCA or a digital sensor. A meter expecting a digital electrode will not read an analogue one, and a mismatched connector makes an otherwise correct electrode unusable.

02

Sample and junction design

Describe the sample, not only the parameter. A double-junction reference places a second barrier between the reference electrolyte and samples carrying sulfides, proteins or heavy metals that would poison a single junction. Samples with solids or high viscosity call for an open junction or a clog-prevention design.

03

Body material and tip shape

Glass bodies resist solvents and are the general laboratory choice; plastic bodies are used where breakage is a hazard, in the field, or in food production. Flat and spear tips exist for surfaces and semi-solids, where a conventional bulb cannot make proper contact.

04

Temperature measurement

Say whether temperature compensation must come from the electrode itself or from a separate probe. A built-in sensor removes an item from the bench but ties temperature and pH to one replacement cycle.

05

Maintenance and consumables

An electrode is a consumable with a service life, not a permanent fitting. Budget storage solution, the correct filling solution for refillable types, cleaning solutions matched to the fouling, and membrane caps where a dissolved oxygen probe is used.

Include this in an electrode request

  • Meter model and connector type
  • Parameter: pH, ORP, conductivity, DO or ISE
  • Sample description, including solids and viscosity
  • Temperature range and whether compensation is required
  • Single or double junction, refillable or gel-filled
  • Storage, filling and cleaning solutions

Common electrode questions

Will any pH electrode fit my meter?

No. The connector — BNC, DIN, Quick Connect or a digital sensor — decides compatibility before any other property of the electrode. Send the meter model with the request and this gets checked first.

Single or double junction — how do I choose?

From the sample. A double junction adds a barrier between the reference electrolyte and the sample, which is the usual choice where sulfides, proteins or heavy metals are present and would poison a single-junction reference.

Glass body or plastic body?

Glass is the general laboratory choice for chemical resistance. Plastic is used where breakage is a hazard, in the field, or in food production. Body material is a separate question from tip shape, which follows the physical form of the sample.

How long should a pH electrode last?

It is a consumable, and service life depends on the sample, temperature and storage rather than a fixed period. Keep storage solution on hand — a pH electrode should never be left dry or standing in deionised water, as both shorten its life.

What the electrode connects to

Buying notes

Nothing above restates a manufacturer specification. Junction design, body material, operating range and service life are specific to the electrode, and compatibility is confirmed against the meter and sample you give us.

Connector compatibility, junction design, chemical resistance and operating range are specific to the electrode and meter quoted. Confirm the meter model and the full sample composition before ordering.