HI1143B – Electrode (Fluoride Application)

Product code: MX-11666

Refillable, combination pH electrode for samples with fluoride (max 2 g/L @ pH 2 and temperature < 60°C) Reference double, Ag/AgCl Junction/Flow Rate ceramic, single / 15-20 μL/h Electrolyte KCl 3.5M Max Pressure 0.1 bar Range pH: 0 to 10 Recommended Operating Temp.

Prices are quoted, not listed.

Ask for a quotation and we’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE

Request a quotation for this item

For a number outside Thailand, start with + and the country code.

A phone number or an email address is enough for us to reply to this request. Privacy Policy

For several items, add each one to a single request.

1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations. The HI1143B uses Fluoride Resistant (HF) glass, spherical bulb, glass body, single ceramic frit, double junction and is refillable with 3.5M KCl. Fluoride Resistant Glass Formulation The measurement of pH in samples containing fluroide is detrimental to the sensitive glass bulb and will shorten the life of it. HF resistant glass is designed for use in aggressive applications that have fluoride ions for extended life. Spherical Bulb The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements. Glass Body The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the electrode reaches equilibrium, the steadier the reference potential. Single Ceramic Double Junction Reference The HI1143B is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is a necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 ?L/hour. Other junction types are available with higher flow rates and made with different materials. Refillable The HI1143B is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings. BNC Connector The HI1143B has a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other types of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These other types of connectors tend to be proprietary for a particular type of meter and are not interchangeable. Single Junction Versus Double Junction pH Electrodes Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Specifications

Referencedouble, Ag/AgCl
Junction/Flow Rateceramic, single / 15-20 μL/h
ElectrolyteKCl 3.5M
Max Pressure0.1 bar
RangepH: 0 to 10
Recommended Operating Temp.-5 to 30°C (23 to 86°F)
Tip/Shapespheric (dia: 9.5 mm)
Temperature Sensorno
Amplifierno
Body Materialglass
Cablecoaxial; 1 m (3.3’)
ConnectionBNC

How quotation ordering works

See the full ordering guide
  1. 01

    Send your requirements

    Send the details you have, even if your list is incomplete. You can also browse the catalog to choose items.

  2. 02

    We check and quote

    We check the details, source the items and prepare your quotation with pricing and delivery information.

  3. 03

    Review and order

    Review the items, prices and delivery details before confirming your order. We flag any item that still needs confirmation.