HI62911D – pH/°C Electrode

Product code: MX-12084

pH / ° C electrode of titanium with PTFE diaphragm, designed for plating baths . Reference Double, Ag/AgCl Junction PTFE (PolyTetraFluoro-Ethylene) Connector DIN Electrolyte Polymer Max Pressure 3 bar Range 0 to 13 pH; 20 to 40°C (68 to 104°F) Tip Shape Flat Temperature Sensor Yes Amplifier Yes Body Material titanium…

Prices are quoted, not listed.

Ask for a quotation and we’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE

Request a quotation for this item

For a number outside Thailand, start with + and the country code.

A phone number or an email address is enough for us to reply to this request. Privacy Policy

For several items, add each one to a single request.

1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations. The HI62911D uses general purpose (GP) glass, flat tip bulb, titanium body, and PTFE junction with polymer electrolyte. General Purpose Glass Formulation The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25°C while the resistance of LT glass is around 50 megaohms at 25°C. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI62911D is suitable to use with samples that measure from 0 to 80°C. Flat Tip Bulb The recessed flat tip bulb of the HI62911D is easy to clean and prevents solids in solution from collecting on the sensor. Other tip shapes include conic for penetration and spheric for aqueous measurements. Titanium Body A titanium body increases immunity to electrostatic and magnetic fields. It also allows for strong corrosion resistance, even in seawater. Out titanium bodied electrodes' outer casing also serves as a matching pin. Matching Pin A matching pin is a differential measurement technique used to eliminate ground loops and common mode perturbations for the measurement system. In a system without a matching pin, electrical currents in the sample can affect the reference half-cell voltage that is connected via the liquid junction with the sample. In this case, the reference electrode picks up the electromagnetic fields and the measurement of the pH is altered. The matching pin isolates these current/magnetic fields from the reference electrode. The HI62911D titanium body serves as a matching pin for safe precise pH measurements. PTFE Junction Porous polytetrafluoroethylene (PTFE) is a hydrophobic material that is available with different porosities. This type of junction is often used on electrodes with polymer electrolytes. Because of its chemical advantages, PTFE is widely used in industrial applications. DIN Connector The HI62911D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI62911D is designed for use with Hanna's HI99131 pH meter. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few. Single Junction Versus Double Junction pH Electrodes Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Specifications

ReferenceDouble, Ag/AgCl
JunctionPTFE (PolyTetraFluoro-Ethylene)
ConnectorDIN
ElectrolytePolymer
Max Pressure3 bar
Range0 to 13 pH; 20 to 40°C (68 to 104°F)
Tip ShapeFlat
Temperature SensorYes
AmplifierYes
Body Materialtitanium body working as matching pin
Cable7-pole; 1 m (3.3′)

How quotation ordering works

See the full ordering guide
  1. 01

    Send your requirements

    Send the details you have, even if your list is incomplete. You can also browse the catalog to choose items.

  2. 02

    We check and quote

    We check the details, source the items and prepare your quotation with pricing and delivery information.

  3. 03

    Review and order

    Review the items, prices and delivery details before confirming your order. We flag any item that still needs confirmation.