HI8710 pH analog Controller with Self Diagnostic

Product code: MX-12559

Inputs: BNC connector, Direct wire connection with amplified probe (supports HI 1006 series probes) and 4-20 mA from a transmitter Extended temperature compensation range: -20 to 100°C Supports potential matching pin connection Both 4-20 and 0-20 mA output ±5V outputs for amplified electrodes Backlit LCD…

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

Fail Safe Alarm System Hanna's exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller. Overtime Dosage "Overtime dosagein. function with selection knob and jumper for disable on the rear panel. If the dosing relay remains continuously activated for more than selected dosing time the alarm relay is activated, the alarm LED is blinking and the dosing relay is deactivated. ORP Dosing Consent Device When used in conjunction with the HI8720 ORP controller, the ORP Dosing Consent Device function will ensure that the ORP dosage will start only when the pH level is correct. Automatic Temperature Compensation A 2-wire Pt100 can be connected to provide automatic temperature compensation of the pH measurements. Matching Pin Connection Supports potential matching pin connection to avoid typical problems caused by grounding loop current, such as progressive damage of the electrode, fluctuating measurements, and poor process regulation. Robust Design A removable, transparent splash-proof cover protects the front panel.

Specifications

Range0.00 to 14.00 pH
Resolution0.01 pH
Accuracy @ 20 °C±0.02 pH (0 to 100 °C) ±0.05 pH (-20 to 0 °C) ±0.5% (input from transmitter)
Inputhigh impedance 10 12 Ohm; reference and matching pin inputs are available; 4-20 mA
Power Output±5 Vcc; 150 mA max load for amplified electrodes
Calibrationoffset: ±2 pH with OFFSET trimmer slope: 80 to 110% with SLOPE trimmer
Temperature Compensationfixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F)
Recorder Output0-20 mA or 4-20 mA (isolated)
Setpoint Relay1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Setpoint Range0.00 to 14.00 pH
Alarm Relay1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Alarm Range0.2 to 3.00 pH
Consent Relay1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Dosing ControlOFF/AUTO/ON with selection switch
Over Dosing Controladjustable, from 5 min to 60 min with knob or disable by wire strap – on rear panel
Backlightcontinuous on
Power Supply115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
Enclosureflame retardant ABS body and front panel; transparent splash-proof front cover
Environment-10 to 50°C (14 to 122°F); RH max 95% non-condensing
Panel Cutout141 x 69 mm (5.6 x 2.7′′)
Weight1 kg (2.2 lb.)