We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

pH & Conductivity Meters

Pocket, portable and benchtop meters for pH, conductivity and TDS, listed with the buffers, standards and related supplies.

TL;DR

pH and conductivity meters: pocket, portable and benchtop

We supply pH and conductivity meters in Thailand: Hanna pocket testers and OHAUS and METTLER TOLEDO portable and benchtop models. Some, such as the Hanna HI98130, read pH, EC, TDS and temperature in one unit. Every meter, buffer and standard is quoted on request.

Compare six meter options

These examples cover different measurement needs. A wider range is not automatically a better fit; confirm the sample, electrode and exact kit before ordering.

Scroll horizontally to see all columns.

Compare six meter options
ModelMeasurementWhat to check
Hanna HI98129Pocket pH/EC/TDS/temperature; EC 0–3999 µS/cm, 1 µS/cm resolution.For combined measurements within this EC range. Compare sample suitability and ±2% full-scale EC accuracy.
Hanna HI98130Pocket pH/EC/TDS/temperature; EC 0.00–20.00 mS/cm, 0.01 mS/cm resolution.For a higher EC range. Its 10 µS/cm display increment is coarser than HI98129's.
OHAUS ST300Portable pH/mV meter; pH 0.00–14.00, 0.01 pH resolution.For moving between sampling points. Confirm the electrode and kit; this is not a conductivity meter.
METTLER TOLEDO FiveGo F2 + LE438Portable pH/mV meter; pH 0.00–14.00, 0.01 pH resolution.For pH measurements at different sampling points. Confirm the LE438 variant and kit; F2 does not measure conductivity.
METTLER TOLEDO F20 + LE438Benchtop pH/mV meter; pH 0–14, 0.01 pH resolution.For pH work at a bench. Check LE438 suitability and any data-output requirement.
OHAUS AB33M1-FBenchtop pH/conductivity meter with two independent channels.For both parameters at one bench. Confirm sensors, working ranges and the exact F kit.

Models for quotation

Include several models in one quotation request and ask about current availability and lead time.

388 products · page 1 of 7

HI98129 COMBO Tester for pH/EC/TDS/C° up to 3999 μS, waterproof

Hanna

HI98129 COMBO Tester for pH/EC/TDS/C° up to 3999 μS, waterproof

MX-12846

HI98130 COMBO Tester for pH/EC/TDS/C° up to 20 mS, waterproof

Hanna

HI98130 COMBO Tester for pH/EC/TDS/C° up to 20 mS, waterproof

MX-12847

ST300 Portable pH Meter

Ohaus

ST300 Portable pH Meter

MX-10606

FiveGo pH F2 + LE438 Portable pH Meter

Mettler Toledo

FiveGo pH F2 + LE438 Portable pH Meter

MX-10321

FiveEasy pH F20 + LE438 Benchtop pH Meter

Mettler Toledo

FiveEasy pH F20 + LE438 Benchtop pH Meter

MX-10052

AB33M1-F Multi-Parameter pH/Conductivity Meter

Ohaus

AB33M1-F Multi-Parameter pH/Conductivity Meter

MX-10378

111800 µS/cm Conductivity Standard (1L)

Hanna

111800 µS/cm Conductivity Standard (1L)

MX-12184

111800 µS/cm Conductivity Standard (230 mL Bottle)

Hanna

111800 µS/cm Conductivity Standard (230 mL Bottle)

MX-12186

12880 µS/cm Conductivity Standard (120mL)

Hanna

12880 µS/cm Conductivity Standard (120mL)

MX-12011

12880 µS/cm Conductivity Standard (1L)

Hanna

12880 µS/cm Conductivity Standard (1L)

MX-12163

12880 µS/cm Conductivity Standard (230mL Bottle)

Hanna

12880 µS/cm Conductivity Standard (230mL Bottle)

MX-12168

12880 µS/cm Conductivity Standard w/ COA (500mL Bottle)

Hanna

12880 µS/cm Conductivity Standard w/ COA (500mL Bottle)

MX-12166

1382 ppm (mg/L) TDS Calibration Standard (500mL)

Hanna

1382 ppm (mg/L) TDS Calibration Standard (500mL)

MX-12068

1413 µS/cm Conductivity Standard (120 mL)

Hanna

1413 µS/cm Conductivity Standard (120 mL)

MX-11181

1413 µS/cm Conductivity Standard (1L)

Hanna

1413 µS/cm Conductivity Standard (1L)

MX-12169

1413 µS/cm Conductivity Standard (230mL Bottle)

Hanna

1413 µS/cm Conductivity Standard (230mL Bottle)

MX-12174

1413 µS/cm Conductivity Standard w/ COA (500mL Bottle)

Hanna

1413 µS/cm Conductivity Standard w/ COA (500mL Bottle)

MX-12171

3 MOL/KCL Solotion, 500 ML

Suntex

3 MOL/KCL Solotion, 500 ML

MX-13359

5000 µS/cm Conductivity Standard (1L)

Hanna

5000 µS/cm Conductivity Standard (1L)

MX-12191

5000 µS/cm Conductivity Standard (230 mL Bottle)

Hanna

5000 µS/cm Conductivity Standard (230 mL Bottle)

MX-12193

80,000 µS/cm Conductivity Standard (120 mL)

Hanna

80,000 µS/cm Conductivity Standard (120 mL)

MX-12013

80000 µS/cm Conductivity Standard (1L)

Hanna

80000 µS/cm Conductivity Standard (1L)

MX-12181

80000 µS/cm Conductivity Standard (230 mL Bottle)

Hanna

80000 µS/cm Conductivity Standard (230 mL Bottle)

MX-12183

84 µS/cm Conductivity Standard (120 mL)

Hanna

84 µS/cm Conductivity Standard (120 mL)

MX-12012

84 µS/cm Conductivity Standard (1L)

Hanna

84 µS/cm Conductivity Standard (1L)

MX-12178

84 µS/cm Conductivity Standard (230mL Bottle)

Hanna

84 µS/cm Conductivity Standard (230mL Bottle)

MX-12180

AB23PH-F Benchtop pH Meter

Ohaus

AB23PH-F Benchtop pH Meter

MX-10426

AB33PH-B+ST310 Benchtop pH Meter

Ohaus

AB33PH-B+ST310 Benchtop pH Meter

MX-10265

Advanced Conductivity Benchtop Meter – HI6321

Hanna

Advanced Conductivity Benchtop Meter – HI6321

MX-11201

AP-1 Pen-Type TDS Meter

HM Digital

AP-1 Pen-Type TDS Meter

MX-10194

Automatic pH Controller – HI981412-00

Hanna

Automatic pH Controller – HI981412-00

MX-12859

Bante220-CN Portable pH Meter

Bante

Bante220-CN Portable pH Meter

MX-10712

Beer pH Tester

Hanna

Beer pH Tester

MX-11242

BL931700-1 pH Mini Controller – 4 – 20mA output – 220V

Hanna

BL931700-1 pH Mini Controller – 4 – 20mA output – 220V

MX-11252

BL932700-1 ORP Mini Controller +/-1000mV – 4 to 20mA output – 220 V

Hanna

BL932700-1 ORP Mini Controller +/-1000mV – 4 to 20mA output – 220 V

MX-11253

BL981411-1 pH Mini Controller (Res 0.1pH) – 220V

Hanna

BL981411-1 pH Mini Controller (Res 0.1pH) – 220V

MX-11268

BL982411-1 ORP Mini Controller upto 1000mV – 230V

Hanna

BL982411-1 ORP Mini Controller upto 1000mV – 230V

MX-11254

BL983314-1 Resistivity Mini Controller, 0.00 to 19.90 MΩ/cm – 230V

Hanna

BL983314-1 Resistivity Mini Controller, 0.00 to 19.90 MΩ/cm – 230V

MX-11256

BL983315-1 TDS Mini Controller 0.0 to 199.9 mg/L (ppm) – 230V

Hanna

BL983315-1 TDS Mini Controller 0.0 to 199.9 mg/L (ppm) – 230V

MX-11257

BL983317-1 EC Mini Controller upto 10.00 mS/cm, 230V

Hanna

BL983317-1 EC Mini Controller upto 10.00 mS/cm, 230V

MX-11258

BL983318-1 TDS Mini Controller 0.0 to 10.00 g/L (ppt) – 230V

Hanna

BL983318-1 TDS Mini Controller 0.0 to 10.00 g/L (ppt) – 230V

MX-11259

BL983319-1 TDS Mini Controller 0.0 to 1999 mg/L (ppm) – 230V

Hanna

BL983319-1 TDS Mini Controller 0.0 to 1999 mg/L (ppm) – 230V

MX-11260

BL983321-1 TDS Mini Controller 0.00 to 19.99 mg/L (ppm) – 230V

Hanna

BL983321-1 TDS Mini Controller 0.00 to 19.99 mg/L (ppm) – 230V

MX-11263

BL983322-1 EC Mini Controller, 0 to 19.99 μS/cm, 230V

Hanna

BL983322-1 EC Mini Controller, 0 to 19.99 μS/cm, 230V

MX-11264

BL983324-1 TDS Mini Controller 0.0 to 49.9 mg/L (ppm) – 230V

Hanna

BL983324-1 TDS Mini Controller 0.0 to 49.9 mg/L (ppm) – 230V

MX-11265

BL983327-1 EC Mini Controller upto 10.00 mS/cm, 230V

Hanna

BL983327-1 EC Mini Controller upto 10.00 mS/cm, 230V

MX-11266

BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) – 230V

Hanna

BL983329-1 TDS Mini Controller 0.0 to 999 mg/L (ppm) – 230V

MX-11267

Buffer Solution pH10.00, 500 ML

Suntex

Buffer Solution pH10.00, 500 ML

MX-13486

Buffer Solution pH4.00, 500 ML

Suntex

Buffer Solution pH4.00, 500 ML

MX-13487

Buffer Solution pH7.00, 500 ML

Suntex

Buffer Solution pH7.00, 500 ML

MX-13488

Calibration Bundle for Agriculture (Bottles)

Hanna

Calibration Bundle for Agriculture (Bottles)

MX-11305

Calibration Bundle for Agriculture (Sachets)

Hanna

Calibration Bundle for Agriculture (Sachets)

MX-11306

Calibration Bundle for Beer (Bottles)

Hanna

Calibration Bundle for Beer (Bottles)

MX-11307

Calibration Bundle for Beer (Sachets)

Hanna

Calibration Bundle for Beer (Sachets)

MX-11308

Calibration Bundle for Cheese

Hanna

Calibration Bundle for Cheese

MX-11309

Calibration Bundle for Dairy

Hanna

Calibration Bundle for Dairy

MX-11310

Calibration Bundle for Food (Bottles)

Hanna

Calibration Bundle for Food (Bottles)

MX-11311

Buyer guide

How to choose a pH or conductivity meter

01

Parameters, units and expected range

List pH and conductivity separately, including the expected range in µS/cm or mS/cm. If reporting TDS, record the conversion factor required by your method. A conductivity-derived TDS result does not identify individual dissolved substances.

02

Match the sample to the sensor

Give the sample type, temperature and container dimensions, plus the existing meter and connector if replacing a probe. A milk sample, a viscous product and low-conductivity water can need different sensor designs. Confirm the exact electrode and meter combination before ordering.

03

A catalog example: HI98130

The Hanna HI98130 listed in our catalog combines pH, EC, TDS and temperature. Its EC range is 0.00 to 20.00 mS/cm with 0.01 mS/cm resolution. That resolution equals 10 µS/cm, so a buyer needing finer low-conductivity readings should specify that requirement before choosing this high-range tester.

04

Budget for the calibration supplies

Choose buffers that cover the expected sample pH and that the meter recognizes. Include the required conductivity standard, electrode storage and cleaning solutions, and replacement-sensor needs. Ask for lot, expiry and certificates where required; an included starter sachet is not a recurring supply plan.

05

Field use, records and receipt

Specify portable or benchtop use, cable length, power and the output format you need. Ask the quotation to separate the instrument, sensor, standards and any calibration service. On receipt, check the model and kit suffix, included items and relevant certificates against the order.

Include this in the quote request

  • Sample or process, expected pH and conductivity range, and measurement temperature
  • Required resolution and accuracy specification, units and any TDS conversion factor
  • Existing meter model, sensor part number and connector, or a complete new system
  • Portable or benchtop use, container size, cable length and data-export needs
  • Buffers, conductivity standards, storage and cleaning solutions; required certificates
  • Quantity, delivery province, required-by date and procurement reference or TOR if used

Common pH and conductivity meter questions

Should I choose HI98129 or HI98130?

Compare the EC range and resolution: HI98129 covers 0–3999 µS/cm in 1 µS/cm steps; HI98130 covers 0.00–20.00 mS/cm in 0.01 mS/cm steps, equivalent to 10 µS/cm. Both specify EC accuracy of ±2% of full scale. The high-range model does not offer finer low-range measurement.

Does 0.01 pH resolution mean ±0.01 pH accuracy?

No. Resolution is the displayed increment. For example, Hanna specifies 0.01 pH resolution and ±0.05 pH accuracy at 25 °C for HI98130. Compare both values and the conditions stated by the manufacturer against your method.

Can one instrument measure both pH and conductivity?

Yes, some models can. HI98130 is one catalog example, but the required ranges and sensor suitability still decide whether it fits. A combined tester does not make every pH electrode or conductivity application interchangeable.

Is a TDS reading the same as a chemical analysis of the water?

No. On a conductivity-based tester, TDS is calculated using a conversion factor. Document that factor when comparing results across instruments; use the relevant analytical method when you need the concentration of a particular substance.

Should I choose a portable or benchtop pH meter?

Start with where the sample will be measured. ST300 and FiveGo F2 are portable pH/mV examples; FiveEasy F20 is a benchtop example. Check the electrode, power supply, cable length and any data-recording requirements for the exact model. Portability alone does not establish accuracy, sensor suitability or conductivity capability.

Continue the measurement setup

Official selection references

Model comparisons use the manufacturer references below. Confirm the electrode, regional kit and sample requirements when requesting a quotation.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.