Digital Refractometer for Brewing
Product code: MX-12819
Hanna Instruments HI96841 Digital Refractometer combines form and function into one compact unit. Featuring a 1.5 second response time, the HI96841 measures the refractive index of wort and converts it to °Plato with temperature compensation.
Used in:Food & beverage
Prices are quoted, not listed.
Ask for a quotation and we’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.
Request a quotation for this item
For several items, add each one to a single request.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Product description
Hanna Instruments HI96841 Digital Refractometer combines form and function into one compact unit. Featuring a 1.5 second response time, the HI96841 measures the refractive index of wort and converts it to °Plato with temperature compensation. The improved easy-to-read LCD screen displays temperature units (°C or °F) and measurements simultaneously. The HI96841's IP65 water-resistant casing and sealed sample well are built to perform under harsh conditions, making it suitable for use in any brewery.
The °Plato scale is a way to quantify the concentration of sugars and dissolved solids in wort. This measurement can indicate the potential alcohol content of finished beer. The HI96841 converts the refractive index reading to °Plato based on the tables maintained by the International Commission for Uniform Methods of Sugar Analysis (ICUMSA) and the American Society of Brewing Chemists (ASBC).
Designed for wort sugar analysis
Temperature compensation algorithms based on sucrose solution
0 to 30 °Plato range with ± 0.2 °Plato
Refractive Index
The HI96841 takes measurements based on a sample's refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample's composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample's refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96841 uses a LED light, prism, and lens to make measurement possible.
Variations in temperature will affect the density of a solution based on the compound that is present. In digital refractometry, the use of temperature compensation is necessary for accurate results. The HI96841 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with the ICUMSA Methods Book for a percent by weight sucrose solution.
Alcohol Interference
It should be noted that once fermentation begins, ethanol and the residual sugar interfere with each other and prevent an accurate reading of the Brix value of your residual sugar.. For this reason, this refractometer cannot be used with finished beer or other fermented beverages. It is designed for use with wort only.
Features-at-a-glance
One-point calibration
Calibrate with distilled or deionized water.
Small sample size
Sample size can be as small as two metric drops (0.1 mL).
Automatic Temperature Compensation (ATC)
Samples automatically compensated for temperature variations.
Quick, accurate results
Readings are displayed in approximately 1.5 seconds.
Dual-level LCD
The dual-level LCD displays measurement and temperature readings simultaneously.
Stainless steel sample well
Easy to clean and corrosion-resistant.
Battery indicators
Battery percent level remaining at startup and low battery indicator.
Automatic shut-off
To conserve battery life the meter shuts off automatically after three minutes of non-use.
IP65 water resistant protection
Water resistant ABS plastic casing designed to perform under laboratory and field conditions.
Specifications
| Sugar Content Range | 0 to 30 °Plato |
|---|---|
| Sugar Content Resolution | 0.1 °Plato |
| Sugar Content Accuracy | ±0.2 °Plato |
| Temperature Range | 0.0 to 80.0°C (32.0 to 176.0°F) |
| Temperature Resolution | 0.1°C (0.1°F) |
| Temperature Accuracy | ±0.3°C (±0.5°F) |
| Automatic Shut-Off | after three minutes of non-use |
| Enclosure Rating | IP65 |
| Dimensions | 192 x 102 x 67 mm (7.6 x 4.01 x 2.6in.) |
| Weight | 420 g (14.8 oz.) |
| Refractometer Light Source | yellow LED |
| Refractometer Temperature Compensation | automatic between 10 and 40°C (50 to 104°F) |
| Minimum Sample Volume | 100 μL (to cover prism totally) |
| Sample Cell | stainless steel ring and flint glass prism |
| Measurement Time | approximately 1.5 seconds |
| Ordering Information | Supplied with battery and instruction manual. |
| Warranty | 2 years |
How quotation ordering works
See the full ordering guide- 01
Send your requirements
Send the details you have, even if your list is incomplete. You can also browse the catalog to choose items.
- 02
We check and quote
We check the details, source the items and prepare your quotation with pricing and delivery information.
- 03
Review and order
Review the items, prices and delivery details before confirming your order. We flag any item that still needs confirmation.