Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter
Product code: MX-12873
The HI98195 is a waterproof portable logging multiparameter meter that monitors up to 9 different water quality parameters. Its multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature.
Prices are quoted, not listed.
Ask for a quotation and we’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.
Request a quotation for this item
For several items, add each one to a single request.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Product description
The HI98195 is a waterproof portable logging multiparameter meter that monitors up to 9 different water quality parameters. Its multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The complete system is simple to set up and easy to use.
Features at-a-glance
Backlit Graphic LCD Display - The HI98195 features a backlit graphic LCD with on-screen help and the capability to display up to nine parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Waterproof Protection - The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
Quick Connect Digital Probe - The HI7698195 probe features a Quick Connect DIN connector that makes a waterproof connection with the meter.
Color Coded, Field Replaceable Sensors - Sensor replacement is quick and easy with field replaceable, screw type connectors that are color-coded for easy sensor port identification.
Auto-sensor Recognition - The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation - Integrated temperature sensor allows for automatic temperature compensation of pH and conductivity measurements.
Standard or Quick Calibration - Quick Calibration provides a speedy, single point calibration for pH and conductivity. Standard pH calibration options are available for calibrating up to three points from a selection of five standard buffers and one custom buffer. Conductivity calibration is a single point from six standard selections or one custom standard.
GLP Data - HI98195 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging - The HI98195 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
Intuitive Keypad - The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help, and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup and logging of data. The interface is intuitive for any user's level of experience.
Dedicated Help Key - Contextual help is always available through a dedicated "HELPin. key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
PC Connectivity - Logged data can be transferred to a Window's compatible PC with the included HI920015 micro USB cable and HI9298194 software.
Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter uses four 1.5V AA batteries that provide up to 360 hours of battery life.
Rugged thermoformed carrying case - The HI98195 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.
On-Screen Features
Setup Screen
Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.
Specifications
| pH Accuracy (@25°C/77°F) | ± 0.02 pH |
|---|---|
| mv Range | ± 600.0 mV |
| mv Accuracy | ± 0.5 mV |
| ORP Range | ± 2000.0 mV |
| ORP Accuracy (@25°C/77°F) | ± 1.0 mV |
| Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
| Temperature Resolution | 0.01 °C, 0.01 °F, 0.01 K |
| Temperature Accuracy (@25°C/77°F) | ± 0.15 °C, ± 0.27 °F, ±0.15 K |
| EC Resolution | auto-ranging: 1 µS/cm from 0 to 9999 µS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm, auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm, 0.01 from 100.0 to 400.0 mS/cm , manual: 1 µ |
| EC Accuracy (@25°C/77°F) | ±1% of reading or ±1 µS/cm whichever is greater |
| TDS Range | 0 to 9999 ppm (mg/L), 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor) |
| TDS Resolution | manual: 1 ppm (mg/L), 0.001 ppt (g/L), 0.01 ppt (g/L), 0.1 ppt (g/L), 1 ppt (g/L), auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L), 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L), 0.1 ppt (g/L) from 100.0 to 400.0 ppt ( |
| TDS Accuracy (@25°C/77°F) | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
| Resistivity Range | 0 to 999999 ©cm, 0 to 1000.0 k©cm, 0 to 1.0000 M©cm |
| Resistivity Accuracy (@25°C/77°F) | dependent on resistivity reading |
| Salinity Accuracy (@25°C/77°F) | ±2% of reading or ±0.01 PSU whichever is greater |
| Log Feature | 45, 000 records (continuous logging or log-on-demand of all parameters) |
| Connectivity | USB to PC with HI9298194 Hanna software installed |
| GLP | Yes |
| Power Supply | 1.5V AA batteries (4) |
| Power Consumption | approximately 360 hours of continuous use without backlight (50 hours with backlight) |
| Environment | 1 to 50°C (32 to 122°F), RH 100% (IP67) |
| Dimensions | 186 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in.) |
| Weight | 401 g (14.2 oz.) |
| Order Information | HI98195 is supplied with HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality c |
| Warranty | 2 years |
| Recommended Probe | HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor |
| pH Range | 0.00 to 14.00 pH |
| pH Resolution | 0.01 pH |
| pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
| mV Resolution | 0.1 mV |
| ORP Resolution | 0.1 mV |
| ORP Calibration | automatic at one custom point (relative mV) |
| EC Range | 0 to 9999 μS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm) |
| EC Calibration | automatic single point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Calibration | based on conductivity calibration |
| Resistivity Calibration | based on conductivity calibration |
| Salinity Range | 0.00 to 70.00 PSU |
| Salinity Resolution | 0.01 PSU |
| Salinity Calibration | based on conductivity calibration |
| Seawater σ Range | 0.0 to 50.0 σt, σ0, σ15 |
| Seawater σ Resolution | 0.1 σt, σ0, σ15 |
| Seawater σ Accuracy | ±1 σt, σ0, σ15 |
| Seawater σ Calibration | based on conductivity calibration |
| Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration |
| Atmospheric Pressure Calibration | automatic at one custom point |
| Temperature Calibration | automatic at one custom point |
| Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
| Logging Interval | one second to three hours |
How quotation ordering works
See the full ordering guide- 01
Send your requirements
Send the details you have, even if your list is incomplete. You can also browse the catalog to choose items.
- 02
We check and quote
We check the details, source the items and prepare your quotation with pricing and delivery information.
- 03
Review and order
Review the items, prices and delivery details before confirming your order. We flag any item that still needs confirmation.