Free quotations · Genuine products · Delivery across Thailand and worldwide

Product code: MX-12920
Dedicated to boiler and cooling tower applications Flat-tipped, pre-amplified pH probe with titanium body Multi-level LCD display On-screen tutorial messages for calibration and set-up Automatic Temperature Compensation Automatic one or two point calibration BEPS (Battery Error Prevention System) alerts the user in…
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Probe Condition An on-screen indicator provides visual confirmation that your probe is working at its best. Low Battery Indicator The included batteries provide 1200 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level. Automatic Shut-off The auto-off feature can be set to shut the meter off at 8 or 60 minutes, or it can be disabled so that the meter continuously stays on. The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on. Built to be Durable Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. These meters are protected against dust and water intrusion from any direction. Portable Design Made to fit comfortably in your hand for on-the-go testing, the multilevel LCD display provides at-a-glance readings of pH and temperature from any angle and dual button operation streamlines the testing process for any user. Quick Connect Probe A Quick Connect DIN connector makes attaching and removing the probe simple and easy. The rubber coating protects the cable and provides a water-tight seal without twisting. Your measurements require detailed attention; so should your electrode. The HI99141 Boiler and Cooling Tower pH Meter features a replaceable HI729113 probe that has been carefully designed for the pH measurement of boiler water or cooling tower water. Titanium Body The titanium body protects your pH electrode from accidental breakage, making it ideal for measurements in plating baths. It also serves as a matching pin to reduce problems caused by electrical currents. Flat Glass Tip The recessed flat tip bulb is easy to clean and prevents solids in plating solutions from collecting on the sensor, reducing maintenance. PTFE Junction This electrode has a unique clog resistant junction that enhances both probe life and accuracy. Due to its chemical advantages, PTFE is widely used in industrial applications. We believe that buying a meter should be simple. Your Plating pH Portable Meter is equipped with everything you need for successful testing right out of the box. Electrode Cleaning Solution Your Boiler and Cooling Tower pH Meter comes with cleaning solution that has been engineered to keep your electrode free from debris. This concentrated combination of detergents cleans your meter quickly and effectively so that your meter stays in optimum condition. pH 4 & 7 Buffer Sachets When performing a pH calibration it is important that the correct buffers are used. We include some start buffers to get you going. The single-use sachets are individually sealed so you use fresh buffer each time you calibrate. HI99141 Models and Compatible Accessories Old HI99141 (Left) Uses the HI72911D pH probe with DIN Connector Compatible with the HI710023 Shockproof Boot New HI9941 (Right) Uses the HI729113 pH probe with Quick DIN Connector Compatible with the HI710028 Shockproof Boot *The new Quick DIN probe connection is compatible with the old body design, however, the old DIN probe connections are not compatible with the new body design.
| Range | pH -2.00 to 16.00 pH |
|---|---|
| Resolution | pH 0.01 pH |
| Accuracy @ 20°C | pH ±0.02 pH |
| pH Calibration | automatic one or two point calibration with two sets of memorized buffers (Standard 4.01, 7.01, 10.01 or NIST 4.01, 6.86, 9.18) |
| Temperature Compensation | Automatic, -5 to 105°C (23 to 221°F) |
| pH Electrode | HI 72911D titanium body, pre-amplified pH electrode with internal temperature sensor, DIN connector and 1 m (3.3’ cable) (included) |
| Battery Type / Life | 1.5V AAA (3) / approximately 1200 hours of continuous use. Auto-off after eight minutes of non-use |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”) |
| Weight | 205g (7.2 oz.) |

Hanna
MX-12184
HI7035/1L is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-12186
H7035M is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-12011

Hanna
MX-12163
H7030/1L is a premium quality 12,880 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.