Pool and Spa pH Controller and Dosing Pump

Product code: MX-13054

Peristaltic Dosing Pump The powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.

Used in:Water & environment

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

Peristaltic Dosing Pump The powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.

Automatic Proportional Pump Control The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point.

Adjustable Flow Rate The dosing pump flow rate is adjustable from 0.5 to 3.5L/h, allowing for better control in maintaining a desired set point.

Acid Tank Level/Flow Switch Input A connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.

Multicolored LCD Display A multi-colored LCD provides a quick way to see the status of the pool controller. The display will show green when operation normally and red while in an alarm state.

Quick Connect Probe Input The Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.

Specifications

pH Range0.00 to 14.00 pH
pH Resolution0.01 pH
pH Accuracy (@25°C/77°F)±0.10 pH
Temperature Range-5.0 to 105°C (23.0 to 221.0°F)
Temperature Resolution0.1°C (0.1°F)
Temperature Accuracy (@25°C/77°F)±0.5°C (±0.9°F)
Temperature Compensationautomatic
Calibrationuser calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH) Process calibration: single point, adjustable (± 0.50 pH around measured pH)
Pump Controlselectable flow rate (0.5 to 3.5 L / hour 0.13 to 0.92 G/hour) manual control for pump priming
Alarmshigh and low with enable / disable option triggered after 5 sec. if controller records a set of consecutive readings over / under threshold values level with enable / disable option overtime protection (1 to 180 min. or off) intuitive alarm system using red, light green, and green color-coded backlight
External Event Inputinput for level controller or flow switch to disable dosing pump in the event of no chemical when using a level controller or no flow when using a flow switch - galvanically isolated
Alarm Relay OutputSPDT 2.5A / 230 VAC
Power Supply100—240 VAC, 50/60 Hz
Power Consumption15 VA
Casingwall mounted, built-in pump, IP65 rated
Environment0-50°C (32-122°F), max. 95% RH non-condensing
Dimensions90 x 142 x 80 mm (3.5 x 5.6 x 1.8in.)
Weight910 g (32 oz.)
Recommended ProbeHI10053 digital pH/temperature probe with quick connect DIN connector - galvanically isolated