Product code: MX-13084
For the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
For the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable. Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution. The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, ?g/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010. Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An "out of calibration rangein. warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values. The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software. Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed. The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages. The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers. On-Screen Features Setup Screen Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides. Calibration pH calibration features detailed CAL Check™ messages. Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination. GLP Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed. ISE Measurements The HI98191 includes ISE measurements when used with our wide selection of ISE electrodes or a custom version. Features and Benefits Ergonomic, rugged, waterproof (IP67) design pH CAL Check™ Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.
| ช่วงการวัด pH | -2.0 – 20.0 pH; -2.00 – 20.00 pH; -2.000 – 20.000 pH |
|---|---|
| ความละเอียด | 0.1 pH; 0.01 pH; 0.001 pH |
| ความถูกต้อง | ±0.1; ±0.002 pH |
| การสอบเทียบ pH | สูงสุด 5 จุดการสอบเทียบ จาก 7 สารละลายมาตรฐาน : 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 และสามารถเลือกจุดโดยผู้ใช้งานได้สูงสุด 5 จุด |
| ช่วงการวัด mV | ±2000 mV |
| ช่วงการวัด ISE | 1.00 E−7 – 9.99 Ei0 concentration |
| การสอบเทียบ ISE | สูงสุด 5 จุดการสอบเทียบ จาก 7 สารละลายมาตรฐาน) |
| ช่วงการวัดอุณหภูมิ | -20.0 – 120.0°C |
| ระบบชดเชยอุณหภูมิ | แบบ manual หรือแบบอัตโนมัติ ในช่วง -20.0 – 120.0°C |
| ค่า Slope ที่เหมาะสม | 80 – 110% |
| หัววัด | HI72911B วัสดุทําจากไทเทเนียม ขั้วต่อชนิด BNC ยาว 1 เมตร |
| ความต้านทาน | 1012 Ohms |
| การเก็บข้อมูล | 300 ข้อมูล |
| การเชื่อมต่อ PC | USB ผ่านโปรแกรม HI92000 และ micro USB |
| แบตเตอรี่ | 1.5V AA batteries (4) / ประมาณ 200 ชั่วโมงแบบต่อเนื่อง โดยไม่รวมในกรณีเปิดโหมด backlight (50 ชั่วโมง รวมเปิดโหมด backlight) |
| ระบบปิดเครื่องแบบอัตโนมัติ | โดยผู้ใช้งาน 5 นาที 10 นาที 30 นาที 60 นาที หรือเลือกไม่ตั้งค่า |
| สภาวะแวดล้อมที่เหมาะสม | 0 to 50°C (32 to 122°F); ความชื้นสัมพัทธ์ 100% (รองรับ IP67) |
| ขนาด | 185 x 93 x 35.2 มม. ล |
| น้ําหนัก | 400 กรัม |

Hanna
MX-12184
HI7035/1L is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-12186
H7035M is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-12011

Hanna
MX-12163
H7030/1L is a premium quality 12,880 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.