Free quotations · Genuine products · Delivery across Thailand and worldwide

Product code: MX-13094
Automatic Temperature Compensation (ATC) Temperature compensation is performed by the transmitter's ATC (Automatic Temperature Compensation) circuitry when measurements are taken with a temperature probe attached; if ATC is not required, it is also possible to substitute a fixed resistor for the temperature probe.
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Automatic Temperature Compensation (ATC) Temperature compensation is performed by the transmitter's ATC (Automatic Temperature Compensation) circuitry when measurements are taken with a temperature probe attached; if ATC is not required, it is also possible to substitute a fixed resistor for the temperature probe. Easy Calibration Calibration is performed by the adjustment of two independent trimmers — slope and offset. Flexible for Your Needs The transmitter can be connected to any Hanna controller that accepts analog input. BNC Connector The transmitters use a universal BNC socket for quick and secure connection to any electrode with a BNC connector. Isolated Input The input is isolated from the current loop to eliminate problems related to ground loop, low insulation cables, multiple electrode connections, and a common mode voltage of up to 100V ensures true differential readings. Version with LCD HI8614in.Lin. versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.
| pH Range | 0.00 to 14.00 pH |
|---|---|
| pH Resolution | 0.01 pH |
| pH Accuracy (@20°C/68°F) | ±0.02 pH |
| mA Output | 4 to 20 mA |
| Typical EMC Deviation | ±0.25 mA / ±0.2 pH |
| Installation Category | II |
| Temperature Compensation | Fixed or automatic from 0 to 100°C (32 to 212°F) with HI76608 probe |
| Calibration | Offset: ±2.2 mA / ±2 pH Slope: ±0.5 mA / 86 to 116% |
| Power Supply | HI8614: 18 to 30 Vdc HI8614L: 20 to 36 Vdc |
| Environment | 0 to 50°C (32 to 122°F) RH max 95% non-condensing |
| Protection | IP65 |
| Dimensions | 165 x 110 x 90 mm (6.5 x 4.3 x 3.5'') |
| Weight | 1 kg (2.2 lb.) |

Hanna
MX-12184
HI7035/1L is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-12186
H7035M is a premium quality 111,800 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.

Hanna
MX-12011

Hanna
MX-12163
H7030/1L is a premium quality 12,880 µS/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.