1/4
HannaAsk about this product on LINE
Pool Digital Combo pH/EC/TDS Tester
Product code: MX-13122
Pool Digital Combo pH/EC/TDS Tester.
Prices are quoted, not listed. Add this product to your quote request and we reply with pricing and availability, usually within one business day. No payment, no account, no minimum order.
1
Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.
Product description
Pool Digital Combo pH/EC/TDS Tester.
Specifications
- pH Range: 0.00 to 14.00 pH
- pH Resolution: 0.01 pH
- pH Accuracy (@25°C/77°F): ±0.05 pH
- pH Calibration: Automatic, one or two-point with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18)
- EC Range: 0.00 to 20.00 mS/cm
- EC Resolution: 0.01 mS/cm
- EC Accuracy: ±2% F.S.
- EC Calibration: Automatic, one point at 12.88 mS/cm or 6.44 ppt (g/L)
- TDS Range: 0.00 to 10.00 g/L (ppt)
- TDS resolution: 0.01 ppt (g/L)
- TDS Accuracy: ±2% F.S.
- TDS Calibration: Automatic, one point at 12.88 mS/cm or 6.44 ppt (g/L)
- Temperature Range: 0.0 to 60.0°C / 32.0 to 140.0°F
- Temperature Resolution: 0.1°C / 0.1°F
- Temperature Accuracy: ±0.5°C /±1°F
- pH Electrode: HI73127 (replaceable, included)
- Automatic Shut-Off: Auto-off after 8 minutes of non-use
- Battery Type Life: 1.5V (4) / approx. 100 hours of continuous use
- Environment: 0 to 50°C (32 to 122°F), RH max 100%
- Dimensions: 163 x 40 x 26 mm (6.4 x 1.6 x 1.0in.)
- Weight: 100 g (3.5 oz.)
- Order Information: HI981304 is supplied with HI73127 pH electrode, HI73128 electrode removal tool, pH 4.01 buffer solution sachet, pH 7.01 buffer solution sachet, 12880 µS/cm conductivity standard sachet, 6.44 ppt TDS standard sachet, pH electro
Specifications
| pH Range | 0.00 to 14.00 pH |
|---|---|
| pH Resolution | 0.01 pH |
| pH Accuracy (@25°C/77°F) | ±0.05 pH |
| pH Calibration | Automatic, one or two-point with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18) |
| EC Range | 0.00 to 20.00 mS/cm |
| EC Resolution | 0.01 mS/cm |
| EC Accuracy | ±2% F.S. |
| EC Calibration | Automatic, one point at 12.88 mS/cm or 6.44 ppt (g/L) |
| TDS Range | 0.00 to 10.00 g/L (ppt) |
| TDS resolution | 0.01 ppt (g/L) |
| TDS Accuracy | ±2% F.S. |
| TDS Calibration | Automatic, one point at 12.88 mS/cm or 6.44 ppt (g/L) |
| Temperature Range | 0.0 to 60.0°C / 32.0 to 140.0°F |
| Temperature Resolution | 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C /±1°F |
| pH Electrode | HI73127 (replaceable, included) |
| Automatic Shut-Off | Auto-off after 8 minutes of non-use |
| Battery Type Life | 1.5V (4) / approx. 100 hours of continuous use |
| Environment | 0 to 50°C (32 to 122°F), RH max 100% |
| Dimensions | 163 x 40 x 26 mm (6.4 x 1.6 x 1.0in.) |
| Weight | 100 g (3.5 oz.) |
| Order Information | HI981304 is supplied with HI73127 pH electrode, HI73128 electrode removal tool, pH 4.01 buffer solution sachet, pH 7.01 buffer solution sachet, 12880 µS/cm conductivity standard sachet, 6.44 ppt TDS standard sachet, pH electro |