The body of the HI2114P/5 is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode.

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

PEI Body

The body of the HI2114P/5 is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.

Cloth Junction

With a renewable cloth junction, the HI2114P/5 has an extended life over typical pH electrodes. A normal junction clogs with use over time and a typical electrode would normally have to be thrown away once the junction becomes contaminated. the HI2114P/5 junction is 2 cm long and when dirty, can be pulled out to expose a fresh section to effectively renew the electrode's life.

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

Multi-pin Connector

The HI2114P/5 uses a multi-pin connector for a tight connection and has a sleeve to protect from spills.

Specifications

Junction / Flow Ratecloth
Electrolytegel
Max Pressure3 bar
RangepH: 0 to 13
Recommended Operating Temperature0 to 80˚C (32 to 176˚F) - GP
Tip / Shapespheric (dia: 7.5 mm)
Diameter12 mm
Body Length122 mm
Temperature Sensorno
Amplifierno
Body MaterialPEI
Cablecoaxial 5m
Connectionmulti-pin