Wastewater Multiparamete with COD Benchtop Photometer and pH meter – HI83314

Product code: MX-13310

Wastewater Multiparamete with COD Benchtop Photometer and pH meter – HI83314 HI83314 benchtop photometer measures 10 different key wastewater quality parameters using 20 different methods that allow for multiple ranges and variations in chemistry for specific applications.

Used in:Water & environment

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

HI83314 benchtop photometer measures 10 different key wastewater quality parameters using 20 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LED's, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time. A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.The HI83314 offers an absorbance measuring mode that allows for CAL CheckTM standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 4 wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.Please note, reagents are not included and can be purchased here.

Specifications

pH RangePhotometer
pH ResolutionPhotometer
pH AccuracyPhotometer
pH CalibrationAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature CompensationAutomatic (-5.0 to 100.0 o C; 23.0 to 212.0 o F); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics)clean electrode and check buffer/check probe displayed during calibration
pH MethodPhotometer
pH-mV Range±1000 mV
pH-mV Resolution0.1 mV
pH-mV Accuracy±0.2 mV
Absorbance Range0.000 to 4.000 Abs
Absorbance Resolution0.001 Abs
Absorbance Accuracy±0.003Abs @ 1.000 Abs
Ammonia RangeLR 0.00 – 3.00 mg/L (NH 3 -N) MR 0.00 – 10.00 mg/L (NH 3 -N) HR 0.0 – 100.0 mg/L (NH 3 -N)
Resolution0.01 mg/L for LR and MR 0.1 mg/L for HR
Accuracy±0.04 mg/L or ±4% of the reading
Ammonia MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
Free Chlorine Range0.00 – 5.00 mg/L
Free Chlorine MethodAdaptation of the EPA 330.5 DPD method
Total Chlorine Range0.00 to 5.00 mg/L (as Cl 2 )
Total Chlorine MethodAdaptation of the EPA 330.5 DPD method
Total Chromium Range0 – 1000 μg/L
Total Chromium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 22 nd edition 3500-Cr and Diphenyl carbazide method
COD RangeLR 0 – 150 mg/L MR 0 – 1500 mg/L HR 0 – 15000 mg/L UHR 0 – 60.0 g/L
COD MethodAdaptation of the USEPA 410.4
Iron Range0.00 – 6.00 mg/L
Iron MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 23 rd edition 3500-Fe B and Phenanthroline method
Nitrate Range0.0-30.0 mg/L (NO 3 – -N)
Nitrate MethodAdaptation of the cadmium reduction method
Nitrite Range0 – 600 μg/L 0.00 – 6.00 mg/L 0 – 150 mg/L
Nitrite MethodAdaptation of the EPA Diazotization method 354.1
Total Nitrogen Range0.0 – 25.0 mg/L 0 – 150 mg/L
Total Nitrogen MethodChromotropic acid method
Phosphorus Range (Acid Hydrolyzable)0.00 to 1.60 mg/L (as P)
Phosphorus Method(Acid Hydrolyzable)Adaptation of the method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
Phosphorus Total Range0.00 – 1.15 mg/L 0.0 – 32.6 mg/L
Phosphorus Total MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition 4500-P C Vanadomolybdophosphoric acid method
Input Channels1 pH electrode input and 5 photometer wavelengths
pH Electrodedigital pH electrode (not included)
Photometer/Colorimeter Light Source5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Photometer/Colorimeter Light Detectorsilicon photodetector
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1 nm
Cuvette Typeround, 24.6 mm
Number of Methods128 max.
GLPcalibration data for connected pH electrode
Display128 x 64 pixel LCD with backlight
Logging Typelog on demand with user name and sample ID optional input
Logging Memory1000 readings
ConnectivityUSB-A host for flash drive; micro-USB-B for power and computer connectivity
Power Supply5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Battery Type/Life3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Environment0 to 50.0 o C (32 to 122.0 o F); 0 to 95% RH, non-condensing
Weight1.0 kg
Dimensions206 x 177 x 97 mm