Skip to content
ไทย

Centrifuges

Laboratory centrifuges from DLAB — low-speed, high-speed, micro and refrigerated models (DM0506, D2012, D1012UA, D1524R) for clinical, research and industrial sample separation. Request a free quotation from ManaEsse X.

Centrifuge selection guide

Match the method, rotor and tube before comparing maximum speed

A useful centrifuge quotation starts with the required separation and sample format. RCF, rotor compatibility, tube size, batch capacity and temperature control are more actionable than a model name alone.

See the checklist and buying questions

23 products

Blood Bag Centrifuge

Hanil

Blood Bag Centrifuge

MX-13479

CR-68X Capp Rondo Mini Centrifuge

Capp

CR-68X Capp Rondo Mini Centrifuge

MX-10767

D1008 Low Speed Centrifuge

DLAB

D1008 Low Speed Centrifuge

MX-10022

D1012UA High Speed Micro Centrifuges

DLAB

D1012UA High Speed Micro Centrifuges

MX-10024

D1524R High Speed Refrigerated Centrifuge

DLAB

D1524R High Speed Refrigerated Centrifuge

MX-10026

D2012 High Speed Centrifuge

DLAB

D2012 High Speed Centrifuge

MX-10023

D3024 High Speed Centrifuge

DLAB

D3024 High Speed Centrifuge

MX-10025

DM0412 Clinical Centrifuge, including A12-10P rotor and both adapterA10P15&A10P15 plug

DLAB

DM0412 Clinical Centrifuge, including A12-10P rotor and both adapterA10P15&A10P15 plug

MX-13570

DM0412S Clinical Centrifuge, 15 ML.

DLAB

DM0412S Clinical Centrifuge, 15 ML.

MX-13571

DM0506 Low Speed Centrifuge

DLAB

DM0506 Low Speed Centrifuge

MX-10021

DM0636 Low Speed Centrifuge

DLAB

DM0636 Low Speed Centrifuge

MX-10027

FC5706 Centrifuge with Rotor 12x15ml

Ohaus

FC5706 Centrifuge with Rotor 12x15ml

MX-10403

FC5706 Centrifuge with Rotor 6x50ml

Ohaus

FC5706 Centrifuge with Rotor 6x50ml

MX-10404

HC-12C Hematocrit Centrifuge

Lugar

HC-12C Hematocrit Centrifuge

MX-10618

KHT-400 Haematocrit Centrifuge

KK

KHT-400 Haematocrit Centrifuge

MX-10718

KHT-430B Haematocrit Centrifuge

KK

KHT-430B Haematocrit Centrifuge

MX-10207

LC-04B Centrifuge

Lugar

LC-04B Centrifuge

MX-10118

LC-04C Centrifuge

Lugar

LC-04C Centrifuge

MX-10165

NF 200 Centrifuge

Nuve

NF 200 Centrifuge

MX-10555

NF048-B50019 Microlitre Centrifuge

Nuve

NF048-B50019 Microlitre Centrifuge

MX-10481

NF048-B50020 Haematocrit Centrifuge

Nuve

NF048-B50020 Haematocrit Centrifuge

MX-10480

Pico17 Haematocrit Centrifuge

Thermo Scientific

Pico17 Haematocrit Centrifuge

MX-10482

RD-HCT-AL Haematocrit Reader

KK

RD-HCT-AL Haematocrit Reader

MX-10792

Centrifuge selection guide

What determines the right centrifuge

01

Method and required RCF

Provide the method’s required relative centrifugal force and run conditions when available. RPM and RCF are not interchangeable without the rotor radius.

02

Tube and rotor

State tube volume, dimensions, material and quantity per run. The exact tube, adapter and rotor combination must be confirmed in the manufacturer documentation.

03

Capacity and workflow

Compare tubes per run, expected batches and turnaround needs. A higher headline speed does not resolve a capacity mismatch.

04

Temperature requirement

Say whether the method requires a refrigerated model and identify the required operating conditions. Temperature performance is model- and rotor-specific.

05

Site and documentation

Include available bench space, electrical supply, noise or placement constraints, and required certificates or manuals.

Centrifuge quote checklist

  • Application or reference method
  • Required RCF and run time
  • Tube type, size and quantity per run
  • Preferred rotor and adapters, if known
  • Refrigeration or temperature requirement
  • Electrical supply, quantity and delivery date

Common centrifuge questions

Should a TOR specify RPM or RCF?

Use the quantity required by the method. RCF describes the force on the sample and depends on both rotational speed and rotor radius, so an RPM value alone may not describe an equivalent separation across different rotors.

Can any tube be used with the selected rotor?

No assumption should be made. Tube dimensions, material, rated force, adapters and rotor compatibility must all be checked in the current instructions for the exact combination.

When should we request a refrigerated centrifuge?

When the method or sample-handling procedure sets a temperature requirement during centrifugation. State that requirement in the quote request rather than selecting refrigeration from the product title alone.

Related laboratory workflow

Official model references

Examples in the live catalog are checked against DLAB’s official product pages. Specifications and compatible rotors must be reconfirmed for the quoted configuration.

Rotor, adapter and tube compatibility is configuration-specific. Do not order from a maximum-speed comparison alone; verify the current manufacturer documentation for the complete setup.