Skip to content
ไทย

Vacuum Pumps

Diaphragm, rotary and water-jet vacuum pumps and aspirators for filtration, evaporation and general lab use.

Vacuum filtration setup guide

Quote the complete filtration path—not the pump alone

A working setup combines a pump, protection trap, tubing, filter holder, receiver and membrane that are compatible with the sample. Chemistry, viscosity, solids and batch volume determine the configuration.

See the checklist and buying questions

65 products · page 1 of 2

C410 Chemistry-design diapharm pump

DLAB

C410 Chemistry-design diapharm pump

MX-10030

Chemker 300, Chemical Resistant Vacuum Pump

Rocker

Chemker 300, Chemical Resistant Vacuum Pump

MX-13509

Chemker 400, Chemical Resistant Vacuum Pump

Rocker

Chemker 400, Chemical Resistant Vacuum Pump

MX-13510

Diaphragm Vacuum Pump

Lab Leader

Diaphragm Vacuum Pump

MX-13562

Diaphragm Vacuum Pump

Lab Leader

Diaphragm Vacuum Pump

MX-13563

Diaphragm Vacuum/Pressure Pump

Lab Leader

Diaphragm Vacuum/Pressure Pump

MX-13561

ME 2 NT Vacuum Pump

VACUUBRAND

ME 2 NT Vacuum Pump

MX-10729

ME 2C NT Chemical Resistance Vacuum Pump

VACUUBRAND

ME 2C NT Chemical Resistance Vacuum Pump

MX-10728

MZ 2C NT Chemical Resistance Vacuum Pump

VACUUBRAND

MZ 2C NT Chemical Resistance Vacuum Pump

MX-10730

Rocker 300 Vacuum Pump

Rocker

Rocker 300 Vacuum Pump

MX-10607

Rocker 300C, PTFE Coated Chemical Resistant Vacuum Pump, AC220V, 50Hz

Rocker

Rocker 300C, PTFE Coated Chemical Resistant Vacuum Pump, AC220V, 50Hz

MX-13936

Rocker 400 Vacuum Pump

Rocker

Rocker 400 Vacuum Pump

MX-10148

Rocker 800 Vacuum Pump

Rocker

Rocker 800 Vacuum Pump

MX-13938

Rocker 900 Vacuum Pump

Rocker

Rocker 900 Vacuum Pump

MX-10354

SHB-IIIA Water Jet Aspirator Pump

HB Biotech

SHB-IIIA Water Jet Aspirator Pump

MX-10175

Buchi V-180 11V180000

Buchi

Buchi V-180 11V180000

MX-16292

Buchi V-300 I300 VacuBox WB 11V300200

Buchi

Buchi V-300 I300 VacuBox WB 11V300200

MX-16308

Buchi V-300 stand alone 11V300000

Buchi

Buchi V-300 stand alone 11V300000

MX-16311

Buchi V-600 stand alone 11V600000

Buchi

Buchi V-600 stand alone 11V600000

MX-16317

Buchi V-80 I-180 11V080200

Buchi

Buchi V-80 I-180 11V080200

MX-16320

Buchi V-80 I-180 WB 11V080210

Buchi

Buchi V-80 I-180 WB 11V080210

MX-16322

Buchi V-80 I-80 11V080100

Buchi

Buchi V-80 I-80 11V080100

MX-16324

Buchi V-80 I-80 WB 11V080110

Buchi

Buchi V-80 I-80 WB 11V080110

MX-16325

Buchi V-80 WB 11V080010

Buchi

Buchi V-80 WB 11V080010

MX-16326

KNF Neuberger N816.3KT.18 Vacuum Pump

KNF Neuberger

KNF Neuberger N816.3KT.18 Vacuum Pump

MX-17346

KNF Neuberger N840G Vacuum Pump

KNF Neuberger

KNF Neuberger N840G Vacuum Pump

MX-17347

KNF Neuberger N96 Vacuum Pump

KNF Neuberger

KNF Neuberger N96 Vacuum Pump

MX-17348

KNF Neuberger SH840G Vacuum Pump

KNF Neuberger

KNF Neuberger SH840G Vacuum Pump

MX-17349

Rocker Scientific ROCKER ROCKER 300C-VF12 189302-22

Rocker Scientific

Rocker Scientific ROCKER ROCKER 300C-VF12 189302-22

MX-19882

No photo

Buchi

Buchi V-180 Condenser 11V180001

MX-16293

No photo

Buchi

Buchi V-180 I-180 11V180200

MX-16294

No photo

Buchi

Buchi V-180 I-180 WB 11V180210

MX-16296

No photo

Buchi

Buchi V-180 I-80 11V180100

MX-16298

No photo

Buchi

Buchi V-180 WB 11V180010

MX-16301

Vacuum filtration setup guide

Five decisions for a complete vacuum filtration setup

01

Sample chemistry

State whether the sample is aqueous, organic, acidic, alkaline or otherwise corrosive. Wetted pump, tubing, holder and flask materials must be checked against the actual chemicals.

02

Vacuum and flow

Give sample volume, viscosity and suspended-solids loading. Pump vacuum and flow should match the filtration duty and receiver size; a higher specification is not automatically faster for every membrane.

03

Pump protection

Use a safety or moisture trap between the receiver and pump where liquid carryover is possible. The trap is intended to reduce the risk of filtrate entering and damaging the pump.

04

Holder, flask and membrane

Specify membrane diameter, material and pore size together with filter-holder and receiver volume. Selection depends on sample compatibility and the required separation.

05

Duty and environment

State run time, batches per day, noise, footprint, voltage and exhaust expectations. Chemical vapor handling and maintenance depend on the pump design.

Include this in a filtration request

  • Sample and chemical composition
  • Batch volume, viscosity and solids
  • Required membrane and pore size
  • Filter holder and receiver volume
  • Vacuum, flow and duty cycle
  • Trap, tubing, voltage and accessories

Vacuum filtration questions

Can I use the same pump for water and organic solvents?

Do not assume so. Rocker distinguishes general aqueous service, PTFE-coated pumps for moderate chemical exposure and fully chemical-resistant designs for corrosive or aggressive vapors. Verify every wetted material for the sample.

Why include a safety trap?

A trap between the receiver and pump helps prevent liquid carryover into the pump during upset or incorrect operation. It does not replace correct setup and supervision.

Does stronger vacuum always make filtration faster?

Not always. Membrane, cake buildup, viscosity, solids, holder area, leaks and receiver size can control the rate. Select the system as a whole.

Related filtration workflows

Official manufacturer references

The component and compatibility checklist follows Rocker Scientific’s current vacuum-filtration and solvent-purification guidance.

Chemical compatibility, vacuum, flow and continuous-duty limits are product-specific. Confirm the complete sample composition and current manufacturer compatibility data before use.