Skip to content
ไทย
1/5
Hanna

pH/ORP/ISE/EC/TDS Advanced Benchtop Meter Kit

Product code: MX-13089

Up to 3 measurements can be shown on the benchtop screen at the same time. Various display configurations and formats are available and can be adjusted in settings.

Prices are quoted, not listed. Add this product to your request. We’ll check the specification, pricing and availability, and confirm the delivery details before you order. No payment, no account, no minimum order.

Ask about this product on LINE
1

Prefer to talk? Call +66 99 241 5692, email us or chat on LINE.

Product description

Easily modify your view options to suit your preferences

Up to 3 measurements can be shown on the benchtop screen at the same time. Various display configurations and formats are available and can be adjusted in settings.

Specifications

pH Range-2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH
pH Resolution0.1 pH, 0.01 pH, 0.001 pH
pH Accuracy±0.1 pH, ±0.01 pH, ±0.002 pH (±1 last significant digit)
Calibration PointsUp to 5
Calibration TypeAutomatic, Semiautomatic, Manual
Standard BuffersHanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Custom BuffersUp to 5
Custom GroupOption to select from eight standard buffers and user-defined custom buffers
First Calibration PointOffset or Point (user setting)
Isopotential Point-2.000 to 20.000 pH
mV Range-2000.0 to 2000.0 mV
mV Resolution1 mV, 0.1 mV
mV Accuracy±0.2 mV ±1 last significant digit
mV CalibrationSingle point offset, ±2000.0 mV
ISE Range1.0×10 ¯5 to 300.0 ppt (g/L or mg/mL) 5.0×10 ¯3 to 1.0×10 5 ppm (mg/L or µg/mL) 1.0 to 5.0×10 7 ppb (µg/L) 1.0×10 ¯7 to 10.0 M (mol/L)cont= 1.0×10 ¯4 to 1.0×10 4 mmol
ISE Resolution1, 2, 3 significant digits
ISE Accuracy±0.5% (monovalent ions), ±1% (divalent ions)
ISE Calibration PointsUp to 5
ISE Calibration TypeAll Standards, Standard Group
ISE Standards7 standard solutions available for each concentration unit
ISE Custom StandardsUp to 5
ISE Custom GroupUp to 5
Conductivity Range0.000 to 9.999 µS/cm, 10.00 to 99.99 µS/cm, 100.0 to 999.9 µS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm
Conductivity Resolution0.001 µS/cm, 0.01 µS/cm, 0.1 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
Conductivity Accuracy±1 % of reading or ±0.010 µS/cm, whichever is greater
Conductivity Cell Constant0.0500 to 200.0000 /cm
Conductivity Calibration TypeAutomatic, Manual
Conductivity Calibration PointsSingle, Up to 5
Conductivity Calibration Solutions84 µS/cm, 1413 µS/cm, 5000 µS/cm, 12880 µS/cm, 80000 µS/cm, 111800 µS/cm
Resistivity Range1.0 to 99.9 Ω•cm, 100 to 999 Ω•cm, 1.00 to 9.99 KΩ•cm, 10.0 to 99.9 KΩ•cm, 100 to 999 KΩ•cm, 1.00 to 9.99 MΩ•cm, 10.0 to 100.0 MΩ•cm
Resistivity Resolution0.1 Ω•cm, 1 Ω•cm, 0.01 KΩ•cm, 0.1 KΩ•cm, 1 KΩ•cm, 0.01 MΩ•cm, 0.1 MΩ•cm
Resistivity Accuracy±1 % of reading or ±1 Ω•cm, whichever is greater
Total Dissolved Solids (TDS) Range0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt, actual TDS (with 1.00 factor)
Total Dissolved Solids (TDS) Resolution0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
Total Dissolved Solids (TDS) Accuracy±1 % of reading or ±0.01 ppm, whichever is greater
Salinity Range0.00 to 42.00 PSU (Practical Salinity Scale), 0.00 to 80.00 ppt (Natural Sea Water), 0.0 to 400.0 % (Percent Scale)
Salinity Resolution0.01 PSU, 0.01 ppt, 0.1 %
Salinity Accuracy±1 % of reading
Salinity Calibration1 point, using 100 % salinity calibration solution (% scale only)
Temperature Range-20.0 to 120.0 °C, -4.0 to 248.0 °F, 253.2 to 393.2 K
Temperature Resolution0.1 °C, 0.1 °F, 0.1 K
Temperature Accuracy±0.2 °C, ±0.4 °F, ±0.2 K
Temperature CalibrationSingle point, adjustable
Temperature CompensationFor pH: Automatic, Manual For Conductivity: Linear, Natural, Standard, Disabled
Reference TemperatureFor Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)
Temperature CoefficientFor Conductivity: 0.00 to 10.00 %/°C
Reading ModeDirect Direct/Autohold ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction Conductivity Only: Direct/USP
Basic ViewMeasurement data, Measurement profile (if enabled), Stability status
Simple GLP ViewBasic view information For pH: pH Last calibration date, slope, offset (pH, Rel. MV - ISE Only) For Conductivity: Last calibration date and offset
Full GLP ViewSimple GLP Information, Calibration point details (pH, ISE, Conductivity, and Salinity)
Graph ViewBasic view information, measurement versus time graph
Table ViewBasic view information, Table with measurements updated every second
Reading Stability CriteriaAccurate, Medium, Fast
Reading Sampling Rate1000 ms
Logging TypeAutomatic, Manual, Autohold
Logging Number of Records50,000 maximum per file and stores at least 1,000,000 data points per user
Logging Automatic Interval1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
Logging Sample IDIncremental Mode, Manual
Logging Export Option.CSV file format
Connectivity USB-A2 ports keyboard and/or printer input USB Flash Drive
Connectivity USB-C1 port PC Connectivity and USB-C Type Flash Drive
Connectivity Wi-Fi & EthernetFTP, Web Server (Log transfer and download), Email
Connectivity RS232Connecting peripherals
Calibration ReminderDaily (0 minutes to 23 hours and 59 minutes), Periodic (1 minute to 30 Days, 23 hours and 59 minutes), or Disabled
UsersUp to 9 users and the default administrator account
Power SupplyDC adapter 100-240 VAC to 24 VDC 2A
Environment0 to 50 °C / 32 to 122 °F / 273 to 323 K maximum 95 % RH non-condensing
Dimensions205 x 160 x 77 mm (8.0 x 6.2 x 3.0 ")
Weight8.05 lbs