Laboratory incubators in natural and forced convection from Memmert (IN and IF series), Binder BD and KB, France Etuves XBE and XBR, plus cooled and BOD models — Memmert IPP, Binder KB and Lovibond TC135S and TC710S — and the BOXUN HPX-9052MBE and BXP-65. For culture work, food and water testing and BOD determination; free, fast quotations.

Incubator selection guide

Start with the set point and the actual room temperature

A microbiological incubator, a cooled BOD incubator and a CO2 incubator are different machines, not grades of one. Fix the application, the set point and the ambient temperature of the room it will stand in before comparing chamber volumes.

See the checklist and buying questions

24 products

BD115 Natural Convection Incubator

Binder

BD115 Natural Convection Incubator

MX-10520

BD56 Natural Convection Incubator

Binder

BD56 Natural Convection Incubator

MX-10519

GC 400 Growth Chamber

Nuve

GC 400 Growth Chamber

MX-10749

IF110 Forced Convection Incubator

Memmert

IF110 Forced Convection Incubator

MX-10680

IF160 Forced Convection Incubator

Memmert

IF160 Forced Convection Incubator

MX-10681

IF260 Forced Convection Incubator

Memmert

IF260 Forced Convection Incubator

MX-10682

IF55 Forced Convection Incubator

Memmert

IF55 Forced Convection Incubator

MX-10678

IF75 Forced Convection Incubator

Memmert

IF75 Forced Convection Incubator

MX-10679

IN110 Natural Convection Incubator

Memmert

IN110 Natural Convection Incubator

MX-10675

IN160 Natural Convection Incubator

Memmert

IN160 Natural Convection Incubator

MX-10676

IN260 Natural Convection Incubator

Memmert

IN260 Natural Convection Incubator

MX-10677

IN55 Natural Convection Incubator

Memmert

IN55 Natural Convection Incubator

MX-10673

IN75 Natural Convection Incubator

Memmert

IN75 Natural Convection Incubator

MX-10674

Incubator LCD Display BXP-65

BOXUN

Incubator LCD Display BXP-65

MX-10043

Incubator Viewing Window HPX-9052MBE

BOXUN

Incubator Viewing Window HPX-9052MBE

MX-10042

KB115 Cooled Incubator

Binder

KB115 Cooled Incubator

MX-10155

KB53 Cooled Incubator

Binder

KB53 Cooled Incubator

MX-10154

XBE058 Forced Convection Incubator

France Etuves

XBE058 Forced Convection Incubator

MX-10077

XBE112 Forced Convection Incubator

France Etuves

XBE112 Forced Convection Incubator

MX-10078

IPP110eco Cooling Incubator

Memmert

IPP110eco Cooling Incubator

MX-10384

IPP55 Cooling Incubator

Memmert

IPP55 Cooling Incubator

MX-10383

XBR112 Cooling Incubator

France Etuves

XBR112 Cooling Incubator

MX-10380

XBR225 Cooling Incubator

France Etuves

XBR225 Cooling Incubator

MX-10381

Incubator selection guide

Five decisions that narrow the incubator shortlist

01

Application and temperature range

State the work and the set point. General microbiology usually sits at 30–37 °C, BOD and environmental work near 20 °C, and mammalian cell culture needs a CO2 incubator, which is a different instrument class.

02

Whether cooling is required

A heat-only incubator can only add heat, so it cannot hold a set point at or below room temperature. Use the measured ambient of the actual installation room rather than a nominal 25 °C — this is what decides between a heated and a cooled unit.

03

Natural convection or forced air

Forced air recovers faster after door openings and generally holds tighter uniformity. Natural convection reduces air movement over open or lightweight samples. Match this to the sample, not to the specification sheet.

04

Chamber volume, shelves and loading

Give plates or flasks per run, shelf count and how often the door is opened per day. Recovery after a door opening usually matters more in practice than the headline uniformity figure.

05

Uniformity, records and alarms

State the uniformity and stability your method requires, plus any need for a calibration certificate, over-temperature protection and logged data. Documentation and alarm behaviour are model- and option-specific.

Include this in an incubator request

  • Application and required set point
  • Whether the set point is below room temperature
  • Chamber volume and plates or flasks per run
  • Natural convection or forced air
  • Required uniformity, calibration and data records
  • Voltage, footprint and required-by date

Common incubator questions

Is a laboratory oven the same as an incubator?

No. Ovens operate well above ambient for drying and sterilising; incubators hold a narrow band close to ambient and are built for uniformity and stability at that band. Name the set point and the application rather than the cabinet type.

Do I need a cooled incubator in Thailand?

You do whenever the set point is at or below room temperature — a 20 °C BOD test is the common case. A heat-only incubator cannot cool below the room it stands in, so check the measured ambient of the installation point, not a nominal figure.

Should I choose natural convection or forced air?

Forced air recovers faster after the door is opened and generally gives tighter uniformity, but the airflow can dry open samples. Natural convection disturbs samples less. Decide from the sample format and how often the door is opened.

Can a CO2 incubator replace a standard incubator?

They are not substitutes. A CO2 incubator controls a CO2 atmosphere and humidity for cell culture. Routine bacteriological work at 35–37 °C does not normally require one, and paying for CO2 control does not improve that work.

Steps either side of incubation

Official manufacturer references

The convection and operating-range fields follow current manufacturer documentation. Range, uniformity and cooling capability are verified against the quoted model.

Temperature range, uniformity, cooling capability and supplied documentation are model-specific. Confirm the set point, the measured ambient at the installation point and current manufacturer data before ordering.