Laboratory Ovens: Hot Air, Drying & Vacuum

Laboratory hot-air, drying and vacuum ovens from Memmert, BINDER and other manufacturers, in natural convection and forced-air designs.

TL;DR

Laboratory ovens: hot-air, drying and vacuum models from Memmert and BINDER

We supply Memmert and BINDER hot-air and drying ovens in natural-convection and forced-air designs, plus BINDER VD vacuum ovens. Most of the hot-air and drying ovens reach 250 °C or 300 °C and the vacuum ovens 200–220 °C, so airflow and what leaves the sample as it dries decide between models. Every model is quoted on request.

Compare five ovens on this shelf

Same-size pairs show what the convection choice does. Figures are the manufacturers’ own, and BINDER measures heat-up and uniformity in an empty chamber; confirm the exact model and options on the quotation.

Scroll horizontally to see all columns.

Compare five ovens on this shelf
ModelDesign and rangeWhat to check
Memmert UN55Natural convection, 53 L; from 5 °C above ambient to 300 °C.For powders and light samples a fan would move. Fresh air enters through an electronically adjustable air flap.
Memmert UF55Forced air, fan adjustable in 10 % steps, 53 L; from 10 °C above ambient to 300 °C.For faster drying and fuller loads; the fan can be turned down for light samples.
BINDER ED 56Natural convection, 57 L; from 5 °C above ambient to 300 °C; uniformity ±2.3 K at 150 °C.50 min to reach 150 °C and 19 min to recover after a 30 s door opening.
BINDER FD 56Forced convection, 60 L; from 10 °C above ambient to 300 °C; uniformity ±1.7 K at 150 °C.15 min to 150 °C and 4 min recovery; 80 air changes an hour at 100 °C against the ED 56’s 8.
BINDER VD 23Vacuum drying, 24 L; from 9 °C above ambient to 220 °C; typical process pressure below 100 mbar.Needs a separate vacuum pump. Rated for non-flammable solvents only; flammable solvents need BINDER’s VDL series.

65 products · page 1 of 2

101-0AB Hot Air Oven with Fan

Faithful

101 Hot Air Oven with Fan

4 variants: 0AB · 1AB · 2AB · 3AB

Choose a variant
DAF RAYPA drying ovens 135 L.

Raypa

DAF RAYPA drying ovens 135 L.

MX-13550

DAF RAYPA drying ovens 250 L.

Raypa

DAF RAYPA drying ovens 250 L.

MX-13551

DAF RAYPA drying ovens 425 L.

Raypa

DAF RAYPA drying ovens 425 L.

MX-13552

Drying Oven 136L.

Biobase

Drying Oven 136L.

MX-13588

Drying Oven, Forced Air (Viewing Window) GZX-MBE Series

BOXUN

Drying Oven, Forced Air (Viewing Window) GZX-MBE Series

MX-10040

Drying Oven, Forced Air 300 °C GZX-MBE Series

BOXUN

Drying Oven, Forced Air 300 °C GZX-MBE Series

MX-10041

ED115 Natural Convection Drying Oven

Binder

ED115 Natural Convection Drying Oven

MX-10711

ED56 Natural Convection Drying Oven

Binder

ED56 Natural Convection Drying Oven

MX-10514

Estufas de secado digitales RAYPA 150 L.

Raypa

Estufas de secado digitales RAYPA 150 L.

MX-13596

Estufas de secado digitales RAYPA 50 L.

Raypa

Estufas de secado digitales RAYPA 50 L.

MX-13597

Estufas de secado digitales RAYPA 90 L.

Raypa

Estufas de secado digitales RAYPA 90 L.

MX-13598

FD115 Forced Convection Drying Oven

Binder

FD115 Forced Convection Drying Oven

MX-10516

FD260 Forced Convection Drying Oven

Binder

FD260 Forced Convection Drying Oven

MX-10243

FD56 Forced Convection Drying Oven

Binder

FD56 Forced Convection Drying Oven

MX-10515

FED115 Forced Convection Hot Air Oven

Binder

FED115 Forced Convection Hot Air Oven

MX-10518

FED56 Forced Convection Hot Air Oven

Binder

FED56 Forced Convection Hot Air Oven

MX-10517

Force Air Drying Oven, 70 L.

Biobase

Force Air Drying Oven, 70 L.

MX-13623

Forced Convection Drying Oven, 150 L .

SH Scientific

Forced Convection Drying Oven, 150 L .

MX-13624

Forced Convection Drying Oven, 54 L .

SH Scientific

Forced Convection Drying Oven, 54 L .

MX-13625

Hot Air Oven FD-Series Binder

Binder

Hot Air Oven FD-Series Binder

MX-10049

Oven Forced Convection 105 L. to 250 °C

Lab Leader

Oven Forced Convection 105 L. to 250 °C

MX-13849

Oven Forced Convection 50 L. to 250 °C

Lab Leader

Oven Forced Convection 50 L. to 250 °C

MX-13850

RAYPA DO analogue drying ovens 150 L.

Raypa

RAYPA DO analogue drying ovens 150 L.

MX-13913

RAYPA DO analogue drying ovens 40 L.

Raypa

RAYPA DO analogue drying ovens 40 L.

MX-13914

RAYPA DO analogue drying ovens 50 L.

Raypa

RAYPA DO analogue drying ovens 50 L.

MX-13915

RAYPA DO analogue drying ovens 90 L.

Raypa

RAYPA DO analogue drying ovens 90 L.

MX-13916

RAYPA EV-50 vacuum oven 50 L.

Raypa

RAYPA EV-50 vacuum oven 50 L.

MX-13917

UF110 Forced Convection Hot Air Oven

Memmert

UF110 Forced Convection Hot Air Oven

MX-10641

UF160 Forced Convection Hot Air Oven

Memmert

UF160 Forced Convection Hot Air Oven

MX-10642

UF260 Forced Convection Hot Air Oven

Memmert

UF260 Forced Convection Hot Air Oven

MX-10643

UF55 Forced Convection Hot Air Oven

Memmert

UF55 Forced Convection Hot Air Oven

MX-10639

UF75 Forced Convection Hot Air Oven

Memmert

UF75 Forced Convection Hot Air Oven

MX-10640

UN110 Natural Convection Hot Air Oven

Memmert

UN110 Natural Convection Hot Air Oven

MX-10646

UN160 Natural Convection Hot Air Oven

Memmert

UN160 Natural Convection Hot Air Oven

MX-10647

UN260 Natural Convection Hot Air Oven

Memmert

UN260 Natural Convection Hot Air Oven

MX-10648

UN55 Natural Convection Hot Air Oven

Memmert

UN55 Natural Convection Hot Air Oven

MX-10645

UN75 Natural Convection Hot Air Oven

Memmert

UN75 Natural Convection Hot Air Oven

MX-10644

VD115 Vacuum Drying Oven

Binder

VD115 Vacuum Drying Oven

MX-10158

VD23 Vacuum Drying Oven

Binder

VD23 Vacuum Drying Oven

MX-10156

VD56 Vacuum Drying Oven

Binder

VD56 Vacuum Drying Oven

MX-10157

WGLL-125BE Hot Air Oven with Fan

Faithful

WGLL-125BE Hot Air Oven with Fan

MX-10296

XUE032 Hot Air Oven with Fan

France Etuves

XUE032 Hot Air Oven with Fan

MX-10168

XUE058 Hot Air Oven with Fan

France Etuves

XUE058 Hot Air Oven with Fan

MX-10629

XUE112 Hot Air Oven with Fan

France Etuves

XUE112 Hot Air Oven with Fan

MX-10630

BINDER 9010-0194 Drying and Heating Oven

Binder

BINDER 9010-0194 Drying and Heating Oven

MX-14105

BINDER 9010-0292 Drying and Heating Oven

Binder

BINDER 9010-0292 Drying and Heating Oven

MX-14108

BINDER 9010-0311 Drying and Heating Oven

Binder

BINDER 9010-0311 Drying and Heating Oven

MX-14115

BINDER 9010-0341 Drying and Heating Oven

Binder

BINDER 9010-0341 Drying and Heating Oven

MX-14127

BINDER 9010-0363 Drying and Heating Oven

Binder

BINDER 9010-0363 Drying and Heating Oven

MX-14128

BINDER 9010-0364 Drying and Heating Oven

Binder

BINDER 9010-0364 Drying and Heating Oven

MX-14129

BINDER 9010-0365 Drying and Heating Oven

Binder

BINDER 9010-0365 Drying and Heating Oven

MX-14130

BINDER 9010-0366 Drying and Heating Oven

Binder

BINDER 9010-0366 Drying and Heating Oven

MX-14131

BINDER 9090-0014 Drying and Heating Oven

Binder

BINDER 9090-0014 Drying and Heating Oven

MX-14175

BINDER 9090-0018 Drying and Heating Oven

Binder

BINDER 9090-0018 Drying and Heating Oven

MX-14177

BINDER 9090-0020 Drying and Heating Oven

Binder

BINDER 9090-0020 Drying and Heating Oven

MX-14178

Laboratory oven selection guide

How to choose a laboratory oven

01

The job and the temperature you will run

Moisture methods state their own point: the USDA reference air-oven method for ground grain runs one hour at 130 °C. The pharmacopoeial reference for dry-heat sterilisation is at least 160 °C for at least 2 hours, and depyrogenating glassware commonly runs 30 minutes at 250 °C. Give the temperature you will actually use; uniformity is specified at a working point.

02

Natural convection or forced air

BINDER’s datasheets for two same-size ovens show the difference: the natural-convection ED 56 takes 50 minutes to reach 150 °C and 19 minutes to recover after a 30-second door opening, the forced-air FD 56 takes 15 and 4. Natural convection still suits powders and light samples a fan would scatter. Both designs release moisture through an adjustable air flap.

03

When the job needs a vacuum oven

Lowering the pressure lowers the boiling point, so water and solvents leave at temperatures the sample can tolerate, with less oxidation. A vacuum oven needs a vacuum pump, quoted as its own line. Check the solvent rating: BINDER’s VD series is for non-flammable solvents, and flammable solvents need its VDL series.

04

Chamber, shelves and load

The model number is not the volume: BINDER’s ED 56 holds 57 L and its FD 56 60 L. Give the trays, crucibles or glassware per run, the number of shelves and the weight of the heaviest shelf, and leave room between the load and the walls. BINDER measures its uniformity figures in an empty chamber.

05

Over-temperature class and records

Under DIN 12880, class 1 cuts the heating only 20–30 °C above the oven’s rated maximum, so it protects the oven rather than your sample; class 2 cuts it at a limit you set until someone resets it; class 3.1 takes over control at that limit. Memmert’s standard UN55 carries class 1; BINDER’s ED and FD carry class 2, and the ED 56 offers 3.1 as an option. For GMP or ISO/IEC 17025 work, ask for a calibration certificate at your working temperature and data logging.

Include this in an oven request

  • The job, and the temperature and time your method specifies
  • Whether the sample gives off solvent or other flammable vapour
  • Natural convection, forced air or vacuum
  • Load per run, number of shelves and heaviest shelf load
  • Over-temperature class, calibration points and data records
  • Voltage, bench or floor space and required-by date

Common laboratory oven questions

Can a hot-air oven sterilise glassware instead of an autoclave?

For dry glassware and metal instruments, yes. The European Pharmacopoeia reference condition, cited in the EMA sterilisation guideline, is at least 160 °C for at least 2 hours; other cycles have to be validated. It does not replace an autoclave for culture media, liquids or most plastics.

Can I dry samples containing ethanol or acetone in a standard oven?

No. BINDER’s manual for its ED, FD and FED ovens states the chambers have no explosion protection and forbids loading anything combustible or explosive at the working temperature. Its VD vacuum ovens are rated for non-flammable solvents only; flammable solvents need the VDL series. Name the solvent and its volume in the request.

Can a moisture analyser replace the oven method?

For routine control, often yes: a halogen moisture analyser gives a result in minutes. The oven stays the reference, and USDA names the air oven as the reference method for moisture in grains and oilseeds, so labs usually correlate the analyser against the oven before relying on it.

Do I need an oven that reaches 300 °C?

Only if your method needs it. The USDA air-oven moisture methods run at 103–130 °C and the dry-heat sterilisation reference is 160 °C. Depyrogenation commonly runs at 250 °C, which is where a 250 or 300 °C rating matters. Ashing belongs in a muffle furnace.

Before and after drying

Manufacturer and regulatory references

Convection, vacuum, range and safety figures come from the manufacturers’ current pages and manuals; the sterilisation and moisture conditions from the regulators named. Range, uniformity and shelf load are verified against the quoted model.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.