01
Sample chemistry
State whether the sample is aqueous, organic, acidic, alkaline or otherwise corrosive. Wetted pump, tubing, holder and flask materials must be checked against the actual chemicals.
Free quotations · Genuine products · Delivery across Thailand, export on request
Diaphragm, rotary and water-jet vacuum pumps and aspirators for filtration, evaporation and general lab use.
TL;DR
We supply laboratory vacuum pumps in Thailand, including VACUUBRAND chemistry diaphragm pumps and Rocker pumps with PTFE-coated and chemical-resistant Chemker models. For filtration, we quote the pump, trap, tubing, filter holder, receiver and membrane as one compatible set. Every item is quoted on request.
116 products · page 2 of 2
Vacuum filtration setup guide
01
State whether the sample is aqueous, organic, acidic, alkaline or otherwise corrosive. Wetted pump, tubing, holder and flask materials must be checked against the actual chemicals.
02
Give sample volume, viscosity and suspended-solids loading. Pump vacuum and flow should match the filtration duty and receiver size; a higher specification is not automatically faster for every membrane.
03
Use a safety or moisture trap between the receiver and pump where liquid carryover is possible. The trap is intended to reduce the risk of filtrate entering and damaging the pump.
04
Specify membrane diameter, material and pore size together with filter-holder and receiver volume. Selection depends on sample compatibility and the required separation.
05
State run time, batches per day, noise, footprint, voltage and exhaust expectations. Chemical vapor handling and maintenance depend on the pump design.
Do not assume so. Rocker distinguishes general aqueous service, PTFE-coated pumps for moderate chemical exposure and fully chemical-resistant designs for corrosive or aggressive vapors. Verify every wetted material for the sample.
A trap between the receiver and pump helps prevent liquid carryover into the pump during upset or incorrect operation. It does not replace correct setup and supervision.
Not always. Membrane, cake buildup, viscosity, solids, holder area, leaks and receiver size can control the rate. Select the system as a whole.
The component and compatibility checklist follows Rocker Scientific’s current vacuum-filtration and solvent-purification guidance.
Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.