Skip to content
ไทย

Centrifuges

Laboratory centrifuges from DLAB — low-speed, high-speed, micro and refrigerated models (DM0506, D2012, D1012UA, D1524R) for clinical, research and industrial sample separation. Request a free quotation from ManaEsse X.

Centrifuge selection guide

Match the method, rotor and tube before comparing maximum speed

A useful centrifuge quotation starts with the required separation and sample format. RCF, rotor compatibility, tube size, batch capacity and temperature control are more actionable than a model name alone.

See the checklist and buying questions

283 products · page 3 of 6

Ohaus 30130877 Benchtop Centrifuge

Ohaus

Ohaus 30130877 Benchtop Centrifuge

MX-19381

Ohaus 30130878 Benchtop Centrifuge

Ohaus

Ohaus 30130878 Benchtop Centrifuge

MX-19382

Ohaus Adapter 1x15ml D17mm 2/pk 30130893

Ohaus

Ohaus Adapter 1x15ml D17mm 2/pk 30130893

MX-19394

Ohaus Adapter 1x16ml D18mm 2/pk 30130892

Ohaus

Ohaus Adapter 1x16ml D18mm 2/pk 30130892

MX-19395

Ohaus Adapter 1x30ml D26mm 2/pk 30130891

Ohaus

Ohaus Adapter 1x30ml D26mm 2/pk 30130891

MX-19397

Ohaus Buckets For 30130880 2/pk 30130895

Ohaus

Ohaus Buckets For 30130880 2/pk 30130895

MX-19411

Ohaus Rotor Angle 6x85ml RB, ID 30314826

Ohaus

Ohaus Rotor Angle 6x85ml RB, ID 30314826

MX-19437

Ohaus Rotor Swing out 6x5ml RB 30130880

Ohaus

Ohaus Rotor Swing out 6x5ml RB 30130880

MX-19441

No photo

Eppendorf

Eppendorf Centrifuge 5420 5420000113

MX-16641

No photo

Eppendorf

Eppendorf Centrifuge 5425 5405000018

MX-16642

No photo

Eppendorf

Eppendorf Centrifuge 5804 R 5805000010

MX-16657

No photo

Eppendorf

Eppendorf Centrifuge 5804 R 5805000320

MX-16658

No photo

Eppendorf

Eppendorf Centrifuge 5804 R 5805000620

MX-16659

No photo

Eppendorf

Eppendorf Centrifuge 5810 R 5811000015

MX-16661

No photo

Eppendorf

Eppendorf Centrifuge 5810 R 5811000420

MX-16662

No photo

Eppendorf

Eppendorf 12PP tube kit (A) 5720411100

MX-16581

No photo

Eppendorf

Eppendorf 15TCX6S adapter 5721244007

MX-16584

No photo

Eppendorf

Eppendorf 40A94 adapter 5720411189

MX-16587

No photo

Eppendorf

Eppendorf 50TCX2S adapter 5721244008

MX-16588

No photo

Eppendorf

Eppendorf Adapter 5425715005

MX-16592

No photo

Eppendorf

Eppendorf Adapter 5425716001

MX-16593

No photo

Eppendorf

Eppendorf Adapter 5427736000

MX-16594

No photo

Eppendorf

Eppendorf Adapter 5427741003

MX-16595

No photo

Eppendorf

Eppendorf Adapter 5427743006

MX-16596

No photo

Eppendorf

Eppendorf Adapter 5702702005

MX-16597

No photo

Eppendorf

Eppendorf Adapter 5804739000

MX-16598

Centrifuge selection guide

What determines the right centrifuge

01

Method and required RCF

Provide the method’s required relative centrifugal force and run conditions when available. RPM and RCF are not interchangeable without the rotor radius.

02

Tube and rotor

State tube volume, dimensions, material and quantity per run. The exact tube, adapter and rotor combination must be confirmed in the manufacturer documentation.

03

Capacity and workflow

Compare tubes per run, expected batches and turnaround needs. A higher headline speed does not resolve a capacity mismatch.

04

Temperature requirement

Say whether the method requires a refrigerated model and identify the required operating conditions. Temperature performance is model- and rotor-specific.

05

Site and documentation

Include available bench space, electrical supply, noise or placement constraints, and required certificates or manuals.

Centrifuge quote checklist

  • Application or reference method
  • Required RCF and run time
  • Tube type, size and quantity per run
  • Preferred rotor and adapters, if known
  • Refrigeration or temperature requirement
  • Electrical supply, quantity and delivery date

Common centrifuge questions

Should a TOR specify RPM or RCF?

Use the quantity required by the method. RCF describes the force on the sample and depends on both rotational speed and rotor radius, so an RPM value alone may not describe an equivalent separation across different rotors.

Can any tube be used with the selected rotor?

No assumption should be made. Tube dimensions, material, rated force, adapters and rotor compatibility must all be checked in the current instructions for the exact combination.

When should we request a refrigerated centrifuge?

When the method or sample-handling procedure sets a temperature requirement during centrifugation. State that requirement in the quote request rather than selecting refrigeration from the product title alone.

Related laboratory workflow

Official model references

Examples in the live catalog are checked against DLAB’s official product pages. Specifications and compatible rotors must be reconfirmed for the quoted configuration.

Rotor, adapter and tube compatibility is configuration-specific. Do not order from a maximum-speed comparison alone; verify the current manufacturer documentation for the complete setup.