The HI96777-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate iron measurements with Hanna's benchtop photometers. These reagents follow the phenanthroline method to determine iron (Fe) concentration.
The HI96776-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate iron measurements with Hanna's benchtop photometers. These reagents follow the phenanthroline method to determine iron (Fe2+ and Fe3+) concentration.
The HI96776-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate iron measurements with Hanna's benchtop photometers. These reagents follow the phenanthroline method to determine iron (Fe2+ and Fe3+) concentration.
The HI93721-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the USEPA method 315B (phenanthroline method) and Standard Method 3500-Fe B.
The HI746-25 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Iron Low Range Checker® HC. These reagents follow the TPTZ Method in which the reaction between iron and reagents causes a violet tint in the sample.
The HI93746-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the TPTZ method. The reaction between iron and the reagent causes a violet tint in the sample.
The HI83741-20 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow a method in which the reaction between iron and reagents causes a purple tint in the sample.
HI7090M is a premium quality ISA solution produced in accordance with ISO 3696/BS3978 standards using high purity reagents, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers.
HI4000-47 is a package containing pH 4 and pH 7 buffer packets with chloride ions and two plastic beakers. The special pH 4 and pH 7 buffers have a chloride background to verify the inner pH glass assembly housed within the ammonia and carbon dioxide gas sensing ISEs.
The ISOLATE II Biofluid RNA Kit provides a simple, efficient column-based method for the isolation of total RNA from a wide variety of starting materials, without the need for hazardous reagents such as phenol.
The ISOLATE II Genomic DNA Kit provides a simple, efficient column-based method for the isolation of genomic DNA from a wide variety of materials, without the need for hazardous reagents such as phenol.
The ISOLATE II miRNA Kit provides a simple, efficient column-based method for the isolation of miRNA and total RNA from a wide variety of starting materials, without the need for hazardous reagents such as phenol, which has been reported to introduce significant bias in recovery of selected small RNAs.
The ISOLATE II PCR and Gel Kit provides a simple, efficient membrane-based method for the purification of DNA from PCR reactions and from TAE and TBE agarose gels, without the need for hazardous reagents or ethanol precipitation.
The ISOLATE II Plant DNA Kit provides a simple, efficient column-based method for the isolation of genomic DNA from a wide variety of plant materials, without the need for hazardous reagents such as phenol.
The ISOLATE II Plasmid Mini Kit provides a simple, efficient column-based method for the isolation of plasmid DNA from bacterial cultures, without the need for hazardous reagents such as phenol.
The ISOLATE II RNA Mini Kit provides a simple, efficient column-based method for the isolation of total RNA from a wide variety of starting materials, without the need for hazardous reagents such as phenol.
The ISOLATE II RNA Plant Kit provides a simple, efficient column-based method for the isolation of total RNA from a wide variety of plant materials, including leaves, bark, roots and fruits, without the need for hazardous reagents such as phenol.
The ISOLATE II RNA/DNA/Protein Kit provides a simple, efficient column-based method for the sequential isolation of total RNA, genomic DNA and proteins from a wide variety of starting materials, without the need for hazardous reagents such as phenol.
A wide-mouth chemical storage bottle with a blue screw cap; inside the cap is a pouring ring that prevents chemicals from spilling or leaking. It is typically used for relatively pure chemicals employed in precise quantitative analysis.
For transferring water or saline, and also effective as a protective sleeve against scratches; Matte, flesh-coloured surface with very good flexibility
Lauryl sulfate broth (LSB) is widely used to detect coliform bacteria in wastewater, dairy products, other food products and clinical samples. It is a cream-yellow, homogeneous, free-flowing powder that dissolves readily in water at 25 °C, pH 6.8 ± 2.
Pack size 500 g. Bacto™ Tryptone is used in preparing microbiological culture media. Ingredients, where noted, meet United States Pharmacopeia (USP) performance specifications.
The HI93754D-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high quality reagents follow the mercury-free dichromate method for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
Plastic cuvette made of polystyrene (Polystyrene); 2.5 ml; Pack size 100 pieces per box; For use with a Spectrophotometer at wavelengths of 340 to 900 nm
The HI93719-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed., colorimetric method.
The HI719-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Magnesium Hardness Checker® HC. These reagents follow the EDTA colorimetric method in which the reaction between magnesium and the reagent causes a violet tint in the sample.
The HI937520-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the calmagite method. The reaction between magnesium and reagents causes a red tint in the sample.
Magnesium sulfate heptahydrate for analysis, EMSURE grade, with both quantity and quality controlled and reported parameters meeting ACS, ISO and/or Reag. Ph Eur standards, giving customers confidence in the quality of the product.
HI709-11 is a high-quality set of calibration standards that allows users to validate the Manganese High Range Checker HC - HI709. The HI709-11 includes one sealed cuvette for zero ppm manganese and one cuvette that is tinted to an equivalent 10.0 ± 0.5 ppm manganese sample @ 25°C.
The HI709-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Manganese High Range Checker® HC. These reagents follow the Periodate method in which the reaction between manganese and the reagents causes a pink tint in the sample.
The HI93709-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, periodate method.
The HI93748-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method. The reaction between manganese and the reagents causes an orange tint in the sample.
HI759-11 is a high quality set of reference standards that allows users to calibrate the HI759 Maple Syrup Digital Grader. The HI759-11 includes two reference cuvettes with a value of 0% transmittance.
Methanol, also known as methyl alcohol, is a non-potable alcohol widely used as an industrial solvent, for example for cleaning plastics, in adhesives for plywood and as a component of biodiesel. It is also a main raw material for producing formaldehyde, a solvent used in paints and polishes.
Tips made of Polypropylene (PP) plastic, Certified RNase, DNase, and endotoxin free; Supplied in a PP box with internal tip slots; 96 tips per box; Can be autoclaved at 120 °C for 20 minutes
Made of virgin polypropylene; Autoclavable; Heat resistant up to 121 °C and cold resistant down to -80 °C; Withstands centrifugal force up to 16,000 g; Supplied in a zip-lock bag
Made of virgin polypropylene; Autoclavable; Heat resistant up to 121 °C; Withstands cold down to -80 °C; Withstands centrifugal force up to 16,000 g; Supplied in a zip-lock bag, pack size 1,000 pieces
Made of virgin polypropylene; Autoclavable; Heat resistant up to 121 °C and cold resistant down to -80 °C; Withstands centrifugal force up to 14,000 g; Supplied in a zip-lock bag; Pack size 500 pieces