The HI93718-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the DPD Method in which the reaction between iodine and reagent causes a pink tint in the sample.
The HI96777-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate iron measurements with Hanna's benchtop photometers. These reagents follow the phenanthroline method to determine iron (Fe) concentration.
The HI96776-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate iron measurements with Hanna's benchtop photometers. These reagents follow the phenanthroline method to determine iron (Fe2+ and Fe3+) concentration.
The HI96776-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate iron measurements with Hanna's benchtop photometers. These reagents follow the phenanthroline method to determine iron (Fe2+ and Fe3+) concentration.
The HI93721-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the USEPA method 315B (phenanthroline method) and Standard Method 3500-Fe B.
The HI746-25 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Iron Low Range Checker® HC. These reagents follow the TPTZ Method in which the reaction between iron and reagents causes a violet tint in the sample.
The HI93746-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the TPTZ method. The reaction between iron and the reagent causes a violet tint in the sample.
The HI83741-20 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow a method in which the reaction between iron and reagents causes a purple tint in the sample.
HI7090M is a premium quality ISA solution produced in accordance with ISO 3696/BS3978 standards using high purity reagents, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers.
HI4000-47 is a package containing pH 4 and pH 7 buffer packets with chloride ions and two plastic beakers. The special pH 4 and pH 7 buffers have a chloride background to verify the inner pH glass assembly housed within the ammonia and carbon dioxide gas sensing ISEs.
The HI93754D-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high quality reagents follow the mercury-free dichromate method for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI93719-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed., colorimetric method.
The HI719-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Magnesium Hardness Checker® HC. These reagents follow the EDTA colorimetric method in which the reaction between magnesium and the reagent causes a violet tint in the sample.
The HI937520-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the calmagite method. The reaction between magnesium and reagents causes a red tint in the sample.
HI709-11 is a high-quality set of calibration standards that allows users to validate the Manganese High Range Checker HC - HI709. The HI709-11 includes one sealed cuvette for zero ppm manganese and one cuvette that is tinted to an equivalent 10.0 ± 0.5 ppm manganese sample @ 25°C.
The HI709-25 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Manganese High Range Checker® HC. These reagents follow the Periodate method in which the reaction between manganese and the reagents causes a pink tint in the sample.
The HI93709-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, periodate method.
The HI93748-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method. The reaction between manganese and the reagents causes an orange tint in the sample.
HI759-11 is a high quality set of reference standards that allows users to calibrate the HI759 Maple Syrup Digital Grader. The HI759-11 includes two reference cuvettes with a value of 0% transmittance.
The HI93730-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the mercaptoacetic acid method. The reaction between molybdenum and the reagents causes a yellow tint in the sample.
The HI93726-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the photometric method. The reaction between nickel and the reagent causes a blue tint in the sample.
The HI93740-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method. The reaction between nickel and the reagents causes an orange tint in the sample.
The HI93766-50 reagent kit contains 50 ready-to-use vials of HI93766V-0 and 50 packets of HI93766-0 nitrate reagent. These high quality reagents follow the chromotropic acid method. In this method, the reaction between nitrate and the reagents causes a yellow tint in the sample.
The HI93728-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the cadmium reduction method in which the reaction between nitrate and the reagent causes an amber tint in the sample.
The HI94766-50 reagent kit contains 50 ready-to-use vials of HI94766V-0 and 50 packets of HI93766-0 nitrate reagent. These high quality reagents follow the chromotropic acid method. In this method, the reaction between nitrate and the reagents causes a yellow tint in the sample.
The HI3874-100 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate nitrate measurements with the chemical test kit. These reagents follow the cadmium reduction method to determine nitrate concentration as nitrate-nitrogen (NO3--N).
The HI93708-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the Ferrous Sulfate method in which the reaction between nitrite and the reagent causes a color change in the sample.
The HI93707-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the Diazotization method, adapted from EPA method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample.
HI84102-60 is a pH 7.00 calibration buffer produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers.
HI84102-61U is a pH 8.20 calibration buffer produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers.