Skip to content
ไทย

Balance

Balances and scales of every type, from analytical and precision balances for the lab to floor and bench scales for production, medical scales and moisture analyzers. Tell us capacity and readability and we will shortlist models. Quotations are free.

Balance & scale selection guide

Specify the smallest sample as well as the heaviest load

A balance must accommodate the container and largest load, while meeting the required accuracy for the smallest net sample. Readability is only the display increment. Start with those two loads and the allowed weighing tolerance before comparing model names or decimal places.

See the checklist and buying questions

544 products · page 4 of 12

WQ2-100L Digital Bench Scale

e-Accura

WQ2 Digital Bench Scale

11 variants: 60L · 60M · 60XL · 100L · 100M · 100XL · 150L · 150M · 150XL · 300XL · 500XL

Choose a variant
WQ2-120-3T Digital Platform Scale

e-Accura

WQ2-3T Digital Platform Scale

2 variants: 120 · 150

Choose a variant
WQ2-A Large Animal Weighing Scale

e-Accura

WQ2-A Large Animal Weighing Scale

MX-10182

WQ2-B Medium Animal Weighing Scale

e-Accura

WQ2-B Medium Animal Weighing Scale

MX-10727

D52XW15WQDR6 Check Weight Scale

Ohaus

D52XW15WQDR6 Check Weight Scale

MX-10262

D52XW30WQDL7 Check Weight Scale

Ohaus

D52XW30WQDL7 Check Weight Scale

MX-10263

D52XW60WTDL7 Check Weight Scale

Ohaus

D52XW60WTDL7 Check Weight Scale

MX-10264

Ohaus 1200g x 0.1g 30467932

Ohaus

Ohaus 1200g x 0.1g 30467932

MX-19373

Ohaus 1500g x 0.01g 30268930

Ohaus

Ohaus 1500g x 0.01g 30268930

MX-19374

Ohaus 30971934 Moisture Balance

Ohaus

Ohaus 30971934 Moisture Balance

MX-19389

Ohaus CR5200 Compact Scale

Ohaus

Ohaus CR5200 Compact Scale

MX-19414

Ohaus D24PE150FL Platform Scale

Ohaus

Ohaus D24PE150FL Platform Scale

MX-19415

Ohaus D24PE30FR Platform Scale

Ohaus

Ohaus D24PE30FR Platform Scale

MX-19416

Ohaus D24PE60FL Platform Scale

Ohaus

Ohaus D24PE60FL Platform Scale

MX-19417

Ohaus D32PE150B2X2 Platform Scale

Ohaus

Ohaus D32PE150B2X2 Platform Scale

MX-19418

Ohaus D32PE300B2V3 Platform Scale

Ohaus

Ohaus D32PE300B2V3 Platform Scale

MX-19419

Ohaus D32PE30B2R1 Platform Scale

Ohaus

Ohaus D32PE30B2R1 Platform Scale

MX-19420

Ohaus D32PE60B2L2 Platform Scale

Ohaus

Ohaus D32PE60B2L2 Platform Scale

MX-19421

Ohaus MB120 Moisture Balance

Ohaus

Ohaus MB120 Moisture Balance

MX-19422

Ohaus MB27 Moisture Balance

Ohaus

Ohaus MB27 Moisture Balance

MX-19423

Ohaus MB95 Moisture Balance

Ohaus

Ohaus MB95 Moisture Balance

MX-19424

Ohaus PX2202 Analytical Balance

Ohaus

Ohaus PX2202 Analytical Balance

MX-19426

Ohaus PX224/E Analytical Balance

Ohaus

Ohaus PX224/E Analytical Balance

MX-19427

Ohaus PX4202 Analytical Balance

Ohaus

Ohaus PX4202 Analytical Balance

MX-19428

Ohaus PX5202/E Analytical Balance

Ohaus

Ohaus PX5202/E Analytical Balance

MX-19429

Ohaus PX523 Analytical Balance

Ohaus

Ohaus PX523 Analytical Balance

MX-19430

Ohaus PX523/E Analytical Balance

Ohaus

Ohaus PX523/E Analytical Balance

MX-19431

Ohaus SJX3201/E Compact Scale

Ohaus

Ohaus SJX3201/E Compact Scale

MX-19443

Ohaus SJX322/E Compact Scale

Ohaus

Ohaus SJX322/E Compact Scale

MX-19444

Ohaus SJX6201/E Compact Scale

Ohaus

Ohaus SJX6201/E Compact Scale

MX-19445

Ohaus SJX622/E Compact Scale

Ohaus

Ohaus SJX622/E Compact Scale

MX-19446

Ohaus T32ME Weighing Indicator

Ohaus

Ohaus T32ME Weighing Indicator

MX-19448

PX3202 2-Decimal-Place Digital Balance

Ohaus

PX3202 2-Decimal-Place Digital Balance

MX-10367

PX3202/E 2-Decimal-Place Digital Balance

Ohaus

PX3202/E 2-Decimal-Place Digital Balance

MX-10368

PX323 3-Decimal-Place Digital Balance

Ohaus

PX323 3-Decimal-Place Digital Balance

MX-10363

PX323/E 3-Decimal-Place Digital Balance

Ohaus

PX323/E 3-Decimal-Place Digital Balance

MX-10364

PX6202 2-Decimal-Place Digital Balance

Ohaus

PX6202 2-Decimal-Place Digital Balance

MX-10365

PX6202/E 2-Decimal-Place Digital Balance

Ohaus

PX6202/E 2-Decimal-Place Digital Balance

MX-10366

PX623 3-Decimal-Place Digital Balance

Ohaus

PX623 3-Decimal-Place Digital Balance

MX-10361

PX623/E 3-Decimal-Place Digital Balance

Ohaus

PX623/E 3-Decimal-Place Digital Balance

MX-10362

AX-MX-30 Disposable Aluminium Pan

A&D

AX-MX-30 Disposable Aluminium Pan

MX-10160

AX-MX-32-2 Glass Fiber Sheets

A&D

AX-MX-32-2 Glass Fiber Sheets

MX-10166

Balance & scale selection guide

Five decisions that narrow the shortlist

01

Capacity, smallest sample and tolerance

Give the maximum gross load including the container, the smallest net sample and the allowable error in mg or percent. A balance that displays a small increment is not automatically suitable for weighing a sample of that size. Minimum usable weight depends on measurement uncertainty and the required tolerance.

02

Compare a named model and its exact variant

Our catalog includes OHAUS PX323 and PX323/E. OHAUS specifies 320 g capacity and 0.001 g readability for PX323, with semi-automatic InCal internal adjustment. Ask the quotation to state the adjustment arrangement and accessories for the exact suffix; matching capacity and display digits alone is not a complete comparison.

03

Match the workplace and load type

Describe airflow, vibration, temperature changes, dust or washdown exposure, and the container footprint. Check the actual model and accessories for a draft shield, pan size and any required IP rating. Patient weighing, floor loads and moisture analysis are separate applications and should be specified as such.

04

Separate adjustment, calibration and routine checks

Internal adjustment helps set the balance response; it is not the same deliverable as an external calibration certificate. If your quality system requires calibration, specify the locations, points, uncertainty reporting and acceptance criteria to agree with the provider. Include suitable check weights and a risk-based routine-check plan where needed.

05

Record handling and receipt

List printing or computer export, connection type and the result fields required by your quality system. At receipt, reconcile the exact model, serial number, accessories and agreed certificates. Complete installation and the checks specified by your method before using the balance for reportable results.

Include this in a weighing request

  • Maximum gross load including the container, and container dimensions
  • Smallest net sample and allowable weighing error in mg or percent
  • Required readability and the method or acceptance specification
  • Airflow, vibration, temperature, dust, washdown or special application
  • Adjustment type, calibration scope, check weights and data-output requirements
  • Quantity, installation location, delivery province, required date and procurement reference

Common balance and scale questions

Does a 0.001 g display mean I can accurately weigh a 0.001 g sample?

No. That number is readability. The minimum sample that meets your tolerance must be assessed from performance and uncertainty in the working environment. Tell the supplier the smallest net sample and the allowed error, not only the number of decimal places.

What is the practical difference between analytical and precision balances?

The terms describe instrument families, but selection still needs the model-specific capacity, readability and performance data. An analytical balance is often chosen for smaller samples; the label alone does not establish that it meets your method.

Does internal calibration remove the need for a calibration certificate?

No. Internal adjustment and a documented calibration serve different purposes. If a certificate is required, agree the service scope, measurement points and uncertainty information separately. Do not assume a factory quality document satisfies the laboratory requirement.

How should we describe a small sample in a heavy container?

State both numbers separately, for example the minimum net sample and the maximum combined container-plus-sample load. The gross load determines needed capacity; the small net addition is what must meet the weighing tolerance.

Related lab guides

Official manufacturer references

The PX323 example follows the manufacturer specification. The selection references explain minimum sample weight, tolerance and calibration in the operating environment; no single minimum weight or calibration interval applies to every laboratory.

Model specifications and a laboratory acceptance assessment determine suitability. If the scale is used for buying or selling by weight, state that use explicitly so the applicable Thai verification requirements can be checked separately.