Balances and scales of every type, from analytical and precision balances for the lab to floor and bench scales for production, medical scales and moisture analyzers. Tell us capacity and readability and we will shortlist models. Quotations are free.

Balance & scale selection guide

Specify the smallest sample as well as the heaviest load

A balance must accommodate the container and largest load, while meeting the required accuracy for the smallest net sample. Readability is only the display increment. Start with those two loads and the allowed weighing tolerance before comparing model names or decimal places.

See the checklist and buying questions

544 products · page 5 of 12

Sartorius 6906940 Balance

Sartorius

Sartorius 6906940 Balance

MX-19902

Sartorius 6906941 Balance

Sartorius

Sartorius 6906941 Balance

MX-19903

Sartorius 6965542 Balance

Sartorius

Sartorius 6965542 Balance

MX-19904

30585411 Aluminium Moisture Pan

Ohaus

30585411 Aluminium Moisture Pan

MX-10791

80252478 Stainless Steel Moisture Pan

Ohaus

80252478 Stainless Steel Moisture Pan

MX-10790

AD-1653 Density Determination Kit

A&D

AD-1653 Density Determination Kit

MX-10183

AX-MX-31 Sample Pan

A&D

AX-MX-31 Sample Pan

MX-10161

RWC65 Battery Charger for Mettler CUB Scale

Mettler Toledo

RWC65 Battery Charger for Mettler CUB Scale

MX-10190

Aluminium Moisture Can

Aluminium Moisture Can

MX-11055

Ohaus 46001724 Analytical Balance

Ohaus

Ohaus 46001724 Analytical Balance

MX-19390

Ohaus 46001780 Analytical Balance

Ohaus

Ohaus 46001780 Analytical Balance

MX-19391

SARTORIUS Base plate SWB69SE0021

Sartorius

SARTORIUS Base plate SWB69SE0021

MX-19919

SARTORIUS Bottom part display SWB69LA0022

Sartorius

SARTORIUS Bottom part display SWB69LA0022

MX-19939

SARTORIUS Bottom part of display SWB69ME0006

Sartorius

SARTORIUS Bottom part of display SWB69ME0006

MX-19940

SARTORIUS Bubble level gauge SWB69MS0114

Sartorius

SARTORIUS Bubble level gauge SWB69MS0114

MX-19946

SARTORIUS Bulb 6V/6W SWB6903150

Sartorius

SARTORIUS Bulb 6V/6W SWB6903150

MX-19947

SARTORIUS Clamping ring SWB69SE0019

Sartorius

SARTORIUS Clamping ring SWB69SE0019

MX-19954

SARTORIUS Coupling male BBI38348012

Sartorius

SARTORIUS Coupling male BBI38348012

MX-19960

SARTORIUS Coupling Pin SWB69A20070

Sartorius

SARTORIUS Coupling Pin SWB69A20070

MX-19961

SARTORIUS Cover glass SWB69SE0015

Sartorius

SARTORIUS Cover glass SWB69SE0015

MX-19962

Sartorius DFO050L Flexsafe RM 50L BBIDFO050L

Sartorius

Sartorius DFO050L Flexsafe RM 50L BBIDFO050L

MX-19963

SARTORIUS Display module SWB69LA0053

Sartorius

SARTORIUS Display module SWB69LA0053

MX-19969

SARTORIUS Display module, complete SWB69SE0013

Sartorius

SARTORIUS Display module, complete SWB69SE0013

MX-19968

SARTORIUS Display SWB69B12184

Sartorius

SARTORIUS Display SWB69B12184

MX-19971

Sartorius Double Tube Heater SWB69MA0483

Sartorius

Sartorius Double Tube Heater SWB69MA0483

MX-19974

SARTORIUS Dust cover,CP 1 Mg SWB6960CP02

Sartorius

SARTORIUS Dust cover,CP 1 Mg SWB6960CP02

MX-19979

SARTORIUS Foot Screws SWB69MS0148

Sartorius

SARTORIUS Foot Screws SWB69MS0148

MX-19992

SARTORIUS Frame (White) SWB69L00047

Sartorius

SARTORIUS Frame (White) SWB69L00047

MX-19997

SARTORIUS Front glass plate SWB69ED0129

Sartorius

SARTORIUS Front glass plate SWB69ED0129

MX-19999

SARTORIUS Front glass plate SWB69MS0048

Sartorius

SARTORIUS Front glass plate SWB69MS0048

MX-20000

SARTORIUS Front glass plate SWB69MS0060

Sartorius

SARTORIUS Front glass plate SWB69MS0060

MX-20001

SARTORIUS Front glass SWB69SE0016

Sartorius

SARTORIUS Front glass SWB69SE0016

MX-20002

Sartorius Front Panel with Foil SWB69ME0014

Sartorius

Sartorius Front Panel with Foil SWB69ME0014

MX-20003

SARTORIUS Ground plate SWB69SE0026

Sartorius

SARTORIUS Ground plate SWB69SE0026

MX-20007

SARTORIUS Groundplate SWB69MA0300

Sartorius

SARTORIUS Groundplate SWB69MA0300

MX-20008

SARTORIUS hood compl. SWB69CP0185

Sartorius

SARTORIUS hood compl. SWB69CP0185

MX-20010

SARTORIUS Hood complete SWB69SE0010

Sartorius

SARTORIUS Hood complete SWB69SE0010

MX-20011

SARTORIUS hood SWB69MA0468

Sartorius

SARTORIUS hood SWB69MA0468

MX-20012

SARTORIUS Hood with display unit SWB69SE0049

Sartorius

SARTORIUS Hood with display unit SWB69SE0049

MX-20013

SARTORIUS Keyboard SWB69MS0008

Sartorius

SARTORIUS Keyboard SWB69MS0008

MX-20031

SARTORIUS Keyboard SWB69Y03073

Sartorius

SARTORIUS Keyboard SWB69Y03073

MX-20032

SARTORIUS Keypad overlay SWB69MA0172

Sartorius

SARTORIUS Keypad overlay SWB69MA0172

MX-20033

SARTORIUS Lateral slide, right SWB69SE0018

Sartorius

SARTORIUS Lateral slide, right SWB69SE0018

MX-20035

SARTORIUS Lateral slide,left SWB69SE0022

Sartorius

SARTORIUS Lateral slide,left SWB69SE0022

MX-20034

SARTORIUS Leveling foot SWB69B20005

Sartorius

SARTORIUS Leveling foot SWB69B20005

MX-20038

Balance & scale selection guide

Five decisions that narrow the shortlist

01

Capacity, smallest sample and tolerance

Give the maximum gross load including the container, the smallest net sample and the allowable error in mg or percent. A balance that displays a small increment is not automatically suitable for weighing a sample of that size. Minimum usable weight depends on measurement uncertainty and the required tolerance.

02

Compare a named model and its exact variant

Our catalog includes OHAUS PX323 and PX323/E. OHAUS specifies 320 g capacity and 0.001 g readability for PX323, with semi-automatic InCal internal adjustment. Ask the quotation to state the adjustment arrangement and accessories for the exact suffix; matching capacity and display digits alone is not a complete comparison.

03

Match the workplace and load type

Describe airflow, vibration, temperature changes, dust or washdown exposure, and the container footprint. Check the actual model and accessories for a draft shield, pan size and any required IP rating. Patient weighing, floor loads and moisture analysis are separate applications and should be specified as such.

04

Separate adjustment, calibration and routine checks

Internal adjustment helps set the balance response; it is not the same deliverable as an external calibration certificate. If your quality system requires calibration, specify the locations, points, uncertainty reporting and acceptance criteria to agree with the provider. Include suitable check weights and a risk-based routine-check plan where needed.

05

Record handling and receipt

List printing or computer export, connection type and the result fields required by your quality system. At receipt, reconcile the exact model, serial number, accessories and agreed certificates. Complete installation and the checks specified by your method before using the balance for reportable results.

Include this in a weighing request

  • Maximum gross load including the container, and container dimensions
  • Smallest net sample and allowable weighing error in mg or percent
  • Required readability and the method or acceptance specification
  • Airflow, vibration, temperature, dust, washdown or special application
  • Adjustment type, calibration scope, check weights and data-output requirements
  • Quantity, installation location, delivery province, required date and procurement reference

Common balance and scale questions

Does a 0.001 g display mean I can accurately weigh a 0.001 g sample?

No. That number is readability. The minimum sample that meets your tolerance must be assessed from performance and uncertainty in the working environment. Tell the supplier the smallest net sample and the allowed error, not only the number of decimal places.

What is the practical difference between analytical and precision balances?

The terms describe instrument families, but selection still needs the model-specific capacity, readability and performance data. An analytical balance is often chosen for smaller samples; the label alone does not establish that it meets your method.

Does internal calibration remove the need for a calibration certificate?

No. Internal adjustment and a documented calibration serve different purposes. If a certificate is required, agree the service scope, measurement points and uncertainty information separately. Do not assume a factory quality document satisfies the laboratory requirement.

How should we describe a small sample in a heavy container?

State both numbers separately, for example the minimum net sample and the maximum combined container-plus-sample load. The gross load determines needed capacity; the small net addition is what must meet the weighing tolerance.

Related lab guides

Official manufacturer references

The PX323 example follows the manufacturer specification. The selection references explain minimum sample weight, tolerance and calibration in the operating environment; no single minimum weight or calibration interval applies to every laboratory.

Model specifications and a laboratory acceptance assessment determine suitability. If the scale is used for buying or selling by weight, state that use explicitly so the applicable Thai verification requirements can be checked separately.