The HI94754D-25 COD kit contains 25 ready-to-use, barcoded vials containing pre-measured reagents. These high quality reagents follow the mercury-free dichromate method for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI93754F-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high quality reagents follow the ISO approved method 15705 for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI94754B-25 COD kit contains 25 ready-to-use, barcoded vials containing pre-measured reagents. These high quality reagents follow the EPA approved method 410.4. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI94754G-25 COD kit contains 25 ready-to-use, barcoded vials containing pre-measured reagents. These high quality reagents follow the ISO approved method 15705. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI94754E-25 COD kit contains 25 ready-to-use, barcoded vials containing pre-measured reagents. These high quality reagents follow the mercury-free dichromate method for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI93754G-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high quality reagents follow the ISO approved method 15705 for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI93754E-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high quality reagents follow the mercury-free dichromate method for determination of COD. In this method, a heated digestion is required to oxidize organic matter in the sample.
The HI83742-25 is a high quality reagent that is pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. This reagent allow for a direct reading of the sample.
HI747-11 is a high-quality set of calibration standards that allows users to validate the Copper Low Range Checker®HC - HI747. The HI747-11 includes one sealed cuvette for zero ppb copper and one cuvette that is tinted to an equivalent 500 ± 100 ppb copper sample @ 25oC.
The HI747-25 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Copper Low Range Checker® HC. These reagents follow the Bicinchoninate Method in which the reaction between copper and the reagent causes a purple tint in the sample.
The HI95747-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the USEPA approved bicinchoninate method. The reaction between copper and the reagent causes a color change in the sample.
The HI83740-20 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow a method in which the reaction between copper and reagents causes a purple tint in the sample.
Features: gloves for general workshop work, worn for lifting heavy items and for grip, with good protection against sparks. Made of quality belly leather, durable and not easily torn, heat resistant to 100 °C.
Material: PC/HDPE -Used for cell cryo preservation and recovery -Unit gives -1 ºC/min cooling rate for 18 cryo vials of 1 or 1.8 ml -Needs 100% isopropyl alcohol and mechanical freesser -HxDia : 86x117 mm
Material: PC-Autoclavable -These Cryo Boxes are a durable and economic alternative to filmsy cardboard Cryo Boxes - These Cryo Boxes can be used in temperature ranging from -196 ºC to +121 ºC - The printed grid on the lid helps in inventory management and prevents misalignment - These Boxes accept writing…
Material: PC-Autoclavable -These Cryo Boxes are a durable and economic alternative to filmsy cardboard Cryo Boxes - These Cryo Boxes can be used in temperature ranging from -196 ºC to +121 ºC - The printed grid on the lid helps in inventory management and prevents misalignment - These Boxes accept writing…
Material: PC-Autoclavable -These Cryo Boxes are a durable and economic alternative to filmsy cardboard Cryo Boxes - These Cryo Boxes can be used in temperature ranging from -196 ºC to +121 ºC - The printed grid on the lid helps in inventory management and prevents misalignment - These Boxes accept writing…
These stackable boxes are designed for storage of sample up to -90°C. The lid is connected to the box base by hinges and a lock on the front of the lid prevents accidental opening of these boxes in the deep freezers. The boxes accomodate 0.5, 1.5 and 2.0 ml micro tubes and 1.0 and 1.8ml Cryo Vials.
Material: PC/Non-toxic gel. An alternative to ice buckets for keeping reagents and enzymes cool. Also protects critical samples from temperature fluctuations in the freezers. Will maintain temperature for approximately 1 hour on the bench. For -20°C Mini Coolers, freeze for 24 hrs at -20°C to -25°C before use.
Material: PC/Non-toxic gel. An alternative to ice buckets for keeping reagents and enzymes cool. Also protects critical samples from temperature fluctuations in the freezers. Will maintain temperature for approximately 1 hour on the bench. For -20°C Mini Coolers, freeze for 24 hrs at -20°C to -25°C before use.
These stackable boxes are designed for storage of sample up to -90°C. The lid is connected to the box base by hinges and a lock on the front of the lid prevents accidental opening of these boxes in the deep freezers. The boxes accomodate 0.5, 1.5 and 2.0 ml micro tubes and 1.0 and 1.8ml Cryo Vials.
Material: PC-Autoclavable -These Cryo Boxes are a durable and economic alternative to filmsy cardboard Cryo Boxes - These Cryo Boxes can be used in temperature ranging from -196 ºC to +121 ºC - The printed grid on the lid helps in inventory management and prevents misalignment - These Boxes accept writing…
The HI93714-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents are used in a method that is adapted from the Standard Methods for the Examination of Water and Wastewater, 18th edition, Pyridine-Pyrazalone method.
The HI93722-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the turbidimetric method. The reaction between cyanuric acid and reagent causes a white suspension in the sample.
A glass measuring cylinder with a hexagonal base and brown graduations, used to measure the volume of liquids or chemicals. Heat and chemical resistant and autoclavable. Supplied with a certificate of accuracy and certified by the Central Bureau of Weights and Measures.
DI water is highly purified distilled, deionised water containing only water molecules (H2O). It is widely used in laboratories and test facilities, and is applied extensively across industry.
di-Potassium hydrogen phosphate trihydrate (also called potassium phosphate dibasic trihydrate), with three molecules of water of crystallisation, is an inorganic salt.
Powder-free synthetic rubber gloves, comfortable to wear and non-irritating, chemical resistant and protective against germs and chemicals; suitable for tattooing, beauty work and general use.
Plastic syringe supplied without a needle. The plunger is pulled or pushed inside the barrel to draw in and expel liquid or gas through the tip, which can be fitted with a needle, a nozzle or tubing to control flow in and out. Commonly used for injections and for intravenous drug administration.
HI7041L is designed to refill the electrolyte solution for polarographic dissolved oxygen probes. Polarographic sensor technology is based on the Ross and Clark polarographic measurement method. An oxygen probe is composed of a platinum electrode and a solid silver electrode.
The HI93732-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the Standard Methods for Examination of Water and Wastewater, 18th edition, azide modified Winkler method.
Highly quality dNTPs are a vital requirement for successful PCR, as the presence of contaminating impurities will result in a decrease in amplification sensitivity and product yield.
The HI93711-D3 are high quality liquid reagents that allow for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.