Skip to content
ไทย

pH meter

pH, conductivity and TDS meters only — pen, portable and benchtop — from Ohaus (ST20, ST300, AB23PH-F, AB33EC-F), Mettler Toledo FiveEasy F20 and FiveGo F2, Eutech PH1710 and CON150, Hanna, Bante and HM Digital, plus Takemura and Rapitest soil testers. Buffers and electrolyte solutions sit under Consumables & Reagents, replacement electrodes under Electrodes & Probes. Free quotation, fast reply.

Buyer guide

Choose the meter, sensor and standards as one measurement system

For a Thai QC laboratory or production team, a useful quotation names the meter, compatible sensor and calibration supplies together. Start with the sample and acceptance requirement, then compare range, uncertainty or accuracy specifications, and the records your method needs.

See the checklist and buying questions

12 products

Electrode Holder for HI42xx Series Benchtop Meters

Hanna

Electrode Holder for HI42xx Series Benchtop Meters

MX-11480

Electrode Holder for pH209 Benchtop Meters

Hanna

Electrode Holder for pH209 Benchtop Meters

MX-11482

HALO2 Wireless pH Tester for Leather & Paper

Hanna

HALO2 Wireless pH Tester for Leather & Paper

MX-11630

HI1001 Industrial-pH-Electrode “Flow-thru” Monitoring, PVDF BNC, 3 m Cable

Hanna

HI1001 Industrial-pH-Electrode “Flow-thru” Monitoring, PVDF BNC, 3 m Cable

MX-11644

HI2114P – Spare pH Electrode

Hanna

HI2114P – Spare pH Electrode

MX-11724

HI73127 Spare-pH-Electrode for Tester

Hanna

HI73127 Spare-pH-Electrode for Tester

MX-12321

Professional Benchtop pH/mV Meter with Built-in Printer

Hanna

Professional Benchtop pH/mV Meter with Built-in Printer

MX-13149

Spare 0.45 µm Filter for PCA Analyzers

Hanna

Spare 0.45 µm Filter for PCA Analyzers

MX-13232

Spare Electrode for Conductivity and TDS testers

Hanna

Spare Electrode for Conductivity and TDS testers

MX-12335

Spare Electrode for PICCOLO® plus pH Tester

Hanna

Spare Electrode for PICCOLO® plus pH Tester

MX-11682

Spare Magnetic Stir Bar for PCA Series Process Analyzers

Hanna

Spare Magnetic Stir Bar for PCA Series Process Analyzers

MX-12969

Spare ORP Electrode for Testers

Hanna

Spare ORP Electrode for Testers

MX-12319

Buyer guide

Five decisions to make before comparing models

01

Parameters, units and expected range

List pH and conductivity separately, including the expected range in µS/cm or mS/cm. If reporting TDS, record the conversion factor required by your method. A conductivity-derived TDS result does not identify individual dissolved substances.

02

Match the sample to the sensor

Give the sample type, temperature and container dimensions, plus the existing meter and connector if replacing a probe. A milk sample, a viscous product and low-conductivity water can need different sensor designs. Confirm the exact electrode and meter combination before ordering.

03

A catalog example: HI98130

The Hanna HI98130 listed in our catalog combines pH, EC, TDS and temperature. Its EC range is 0.00 to 20.00 mS/cm with 0.01 mS/cm resolution. That resolution equals 10 µS/cm, so a buyer needing finer low-conductivity readings should specify that requirement before choosing this high-range tester.

04

Budget for the calibration supplies

Choose buffers that cover the expected sample pH and that the meter recognizes. Include the required conductivity standard, electrode storage and cleaning solutions, and replacement-sensor needs. Ask for lot, expiry and certificates where required; an included starter sachet is not a recurring supply plan.

05

Field use, records and receipt

Specify portable or benchtop use, cable length, power and the output format you need. Ask the quotation to separate the instrument, sensor, standards and any calibration service. On receipt, check the model and kit suffix, included items and relevant certificates against the order.

Include this in the quote request

  • Sample or process, expected pH and conductivity range, and measurement temperature
  • Required resolution and accuracy specification, units and any TDS conversion factor
  • Existing meter model, sensor part number and connector, or a complete new system
  • Portable or benchtop use, container size, cable length and data-export needs
  • Buffers, conductivity standards, storage and cleaning solutions; required certificates
  • Quantity, delivery province, required-by date and procurement reference or TOR if used

Common pH and conductivity meter questions

Does 0.01 pH resolution mean ±0.01 pH accuracy?

No. Resolution is the displayed increment. For example, Hanna specifies 0.01 pH resolution and ±0.05 pH accuracy at 25 °C for HI98130. Compare both values and the conditions stated by the manufacturer against your method.

Can one instrument measure both pH and conductivity?

Yes, some models can. HI98130 is one catalog example, but the required ranges and sensor suitability still decide whether it fits. A combined tester does not make every pH electrode or conductivity application interchangeable.

Is a TDS reading the same as a chemical analysis of the water?

No. On a conductivity-based tester, TDS is calculated using a conversion factor. Document that factor when comparing results across instruments; use the relevant analytical method when you need the concentration of a particular substance.

Which buffers and accessories should appear in the quotation?

Request buffers that bracket the sample range and match the meter settings, the specified EC standard where needed, and suitable storage and cleaning solutions. State required pack sizes and certificates. Confirm the exact kit contents rather than assuming a meter includes a full year of consumables.

Continue the measurement setup

Official selection references

The HI98130 example follows its manufacturer specification. The buffer-selection references explain calibration range and solution care; the quoted sensor and method still determine the final setup.

This guide helps define a quotation. It does not replace your laboratory method, quality procedure or the current instructions for the selected instrument and sensor.