Viscometer buying guide

A viscosity result belongs to a complete test condition

For comparable results, define the viscometer model or torque range, spindle, speed, temperature, container and sample preparation together. A viscosity value without those conditions may not reproduce the same test.

507 products · page 1 of 9

BDV-1A Viscometer

Biobase

BDV-1A Viscometer

MX-10419

DVPLLV Viscometer

AMETEK Brookfield

DVPLLV Viscometer

MX-10351

Brookfield 2.5XHBDVNX CP Rheometer,BB,ASIA

AMETEK Brookfield

Brookfield 2.5XHBDVNX CP Rheometer,BB,ASIA

MX-14252

Brookfield 2XHBDVNX CP Rheometer,BB,ASIA

AMETEK Brookfield

Brookfield 2XHBDVNX CP Rheometer,BB,ASIA

MX-14254

Brookfield 5XHBDV2T Viscometer,TC,BB,

AMETEK Brookfield

Brookfield 5XHBDV2T Viscometer,TC,BB,

MX-14263

Brookfield 5XHBDVNX CP Rheometer,BB,ASIA

AMETEK Brookfield

Brookfield 5XHBDVNX CP Rheometer,BB,ASIA

MX-14264

Brookfield 5XHBDVNX CP Rheometer,MAG,BB,ASIA

AMETEK Brookfield

Brookfield 5XHBDVNX CP Rheometer,MAG,BB,ASIA

MX-14265

Brookfield 5XHBDVNX Rheometer,TC,BB,ASIA

AMETEK Brookfield

Brookfield 5XHBDVNX Rheometer,TC,BB,ASIA

MX-14266

Brookfield 5XLVDV2T Viscometer,TC,PJ,

AMETEK Brookfield

Brookfield 5XLVDV2T Viscometer,TC,PJ,

MX-14267

Brookfield GV-1098 Viscometer

AMETEK Brookfield

Brookfield GV-1098 Viscometer

MX-14378

Brookfield HA Analog Master Visc, glass win,

AMETEK Brookfield

Brookfield HA Analog Master Visc, glass win,

MX-14381

Brookfield HA Analog Viscometer, glass win,

AMETEK Brookfield

Brookfield HA Analog Viscometer, glass win,

MX-14382

Brookfield HADV2P Viscometer,MAG,BB,ASIA

AMETEK Brookfield

Brookfield HADV2P Viscometer,MAG,BB,ASIA

MX-14384

Brookfield HADV2P Viscometer,MAG,PJ,ASIA

AMETEK Brookfield

Brookfield HADV2P Viscometer,MAG,PJ,ASIA

MX-14385

Brookfield HADV2T Viscometer,MAG,BB,

AMETEK Brookfield

Brookfield HADV2T Viscometer,MAG,BB,

MX-14386

Brookfield HADV2T Viscometer,MAG,PJ,

AMETEK Brookfield

Brookfield HADV2T Viscometer,MAG,PJ,

MX-14387

Brookfield HADV2T Viscometer,TC,BB,

AMETEK Brookfield

Brookfield HADV2T Viscometer,TC,BB,

MX-14388

Brookfield HADV2T Viscometer,TC,PJ,

AMETEK Brookfield

Brookfield HADV2T Viscometer,TC,PJ,

MX-14389

Brookfield HADVNX CP Rheometer,BB,ASIA

AMETEK Brookfield

Brookfield HADVNX CP Rheometer,BB,ASIA

MX-14390

Brookfield HADVNX CP Rheometer,MAG,PJ,ASIA

AMETEK Brookfield

Brookfield HADVNX CP Rheometer,MAG,PJ,ASIA

MX-14391

Brookfield HADVPL Viscometer,MAG,BB,ASIA

AMETEK Brookfield

Brookfield HADVPL Viscometer,MAG,BB,ASIA

MX-14393

Brookfield HBDV2P Viscometer,TC,BB,ASIA

AMETEK Brookfield

Brookfield HBDV2P Viscometer,TC,BB,ASIA

MX-14395

Brookfield HBDVNX CP Rheometer,MAG,BB,ASIA

AMETEK Brookfield

Brookfield HBDVNX CP Rheometer,MAG,BB,ASIA

MX-14396

Brookfield HBDVPL Viscometer,BB,MAG,ASIA XDVPLHBMB00C00

AMETEK Brookfield

Brookfield HBDVPL Viscometer,BB,MAG,ASIA XDVPLHBMB00C00

MX-14398

Brookfield KU3 Master Viscometer

AMETEK Brookfield

Brookfield KU3 Master Viscometer

MX-14433

Brookfield KU3A Viscometer,QC,BB,Type I Cord

AMETEK Brookfield

Brookfield KU3A Viscometer,QC,BB,Type I Cord

MX-14434

Brookfield KU3A Viscometer,QC,BB,WITHOUT

AMETEK Brookfield

Brookfield KU3A Viscometer,QC,BB,WITHOUT

MX-14435

Brookfield LV Analog Master Visc, glass win,

AMETEK Brookfield

Brookfield LV Analog Master Visc, glass win,

MX-14463

Brookfield LV Analog Viscometer, glass win,

AMETEK Brookfield

Brookfield LV Analog Viscometer, glass win,

MX-14464

Brookfield LV Analog Viscometer, glass win, without

AMETEK Brookfield

Brookfield LV Analog Viscometer, glass win, without

MX-14465

Brookfield LVDV2P Viscometer,MAG,PJ,ASIA

AMETEK Brookfield

Brookfield LVDV2P Viscometer,MAG,PJ,ASIA

MX-14470

Brookfield LVDV2P Viscometer,TC,PJ,ASIA

AMETEK Brookfield

Brookfield LVDV2P Viscometer,TC,PJ,ASIA

MX-14471

Brookfield LVDV2T Viscometer MAG,PJ 220V XDV2TLVMJ00U00

AMETEK Brookfield

Brookfield LVDV2T Viscometer MAG,PJ 220V XDV2TLVMJ00U00

MX-14474

Brookfield LVDV2T Viscometer,GEL/T,TC,PJ,

AMETEK Brookfield

Brookfield LVDV2T Viscometer,GEL/T,TC,PJ,

MX-14472

Brookfield LVDV2T Viscometer,MAG,PJ,

AMETEK Brookfield

Brookfield LVDV2T Viscometer,MAG,PJ,

MX-14473

Brookfield LVDV2T Viscometer,TC,PJ,

AMETEK Brookfield

Brookfield LVDV2T Viscometer,TC,PJ,

MX-14475

Brookfield LVDV2T Viscometer,TC,PJ,WITHOUT

AMETEK Brookfield

Brookfield LVDV2T Viscometer,TC,PJ,WITHOUT

MX-14476

Brookfield LVDVNX CP Rheometer,MAG,PJ,ASIA

AMETEK Brookfield

Brookfield LVDVNX CP Rheometer,MAG,PJ,ASIA

MX-14477

Brookfield LVDVNX CP Rheometer,MAG,PJ,COMP ASIA

AMETEK Brookfield

Brookfield LVDVNX CP Rheometer,MAG,PJ,COMP ASIA

MX-14478

Brookfield LVDVNX Rheometer,MAG,PJ 220V XDVNXLVMJG0U00

AMETEK Brookfield

Brookfield LVDVNX Rheometer,MAG,PJ 220V XDVNXLVMJG0U00

MX-14481

Brookfield LVDVPL Viscometer,MAG,PJ,ASIA XDVPLLVMJ00C00

AMETEK Brookfield

Brookfield LVDVPL Viscometer,MAG,PJ,ASIA XDVPLLVMJ00C00

MX-14484

Brookfield LVDVPL Viscometer,TC,PJ,ASIA XDVPLLVTJ00C00

AMETEK Brookfield

Brookfield LVDVPL Viscometer,TC,PJ,ASIA XDVPLLVTJ00C00

MX-14485

Brookfield RV Analog Master Visc, glass win,

AMETEK Brookfield

Brookfield RV Analog Master Visc, glass win,

MX-14583

Brookfield RV Analog Viscometer, glass win,

AMETEK Brookfield

Brookfield RV Analog Viscometer, glass win,

MX-14584

Brookfield RV Analog Viscometer, glass win, without

AMETEK Brookfield

Brookfield RV Analog Viscometer, glass win, without

MX-14585

Brookfield RVDV2P Viscometer,MAG,PJ,ASIA

AMETEK Brookfield

Brookfield RVDV2P Viscometer,MAG,PJ,ASIA

MX-14591

Brookfield RVDV2P Viscometer,TC,PJ,ASIA

AMETEK Brookfield

Brookfield RVDV2P Viscometer,TC,PJ,ASIA

MX-14592

Brookfield RVDV2T Vicometer MAG,PJ 220V XDV2TRVMJ00U00

AMETEK Brookfield

Brookfield RVDV2T Vicometer MAG,PJ 220V XDV2TRVMJ00U00

MX-14593

Brookfield RVDV2T Viscometer,TC,PJ,WITHOUT

AMETEK Brookfield

Brookfield RVDV2T Viscometer,TC,PJ,WITHOUT

MX-14594

Brookfield RVDVNX CP Rheometer,BB,ASIA

AMETEK Brookfield

Brookfield RVDVNX CP Rheometer,BB,ASIA

MX-14595

Brookfield RVDVNX CP Rheometer,MAG,PJ,ASIA

AMETEK Brookfield

Brookfield RVDVNX CP Rheometer,MAG,PJ,ASIA

MX-14596

Brookfield RVDVNX Rheometer,MAG,PJ 220V XDVNXRVMJG0U00

AMETEK Brookfield

Brookfield RVDVNX Rheometer,MAG,PJ 220V XDVNXRVMJG0U00

MX-14599

Brookfield RVDVNX Rheometer,PJ - CP XDVNXRVCJG0U00

AMETEK Brookfield

Brookfield RVDVNX Rheometer,PJ - CP XDVNXRVCJG0U00

MX-14600

Brookfield RVDVPL Viscometer,MAG,PJ,ASIA XDVPLRVMJ00C00

AMETEK Brookfield

Brookfield RVDVPL Viscometer,MAG,PJ,ASIA XDVPLRVMJ00C00

MX-14602

Brookfield RVDVPL Viscometer,TC,BB,ASIA XDVPLRVTB00C00

AMETEK Brookfield

Brookfield RVDVPL Viscometer,TC,BB,ASIA XDVPLRVTB00C00

MX-14603

Viscometer buying guide

Five choices to define before selecting a viscometer

01

Method or historical setup

If a specification or established test names the instrument, spindle and speed, reproduce that setup. This preserves comparability with earlier results and customer requirements.

02

Viscosity and torque range

Give the expected minimum and maximum viscosity. Brookfield guidance recommends choosing spindle and speed combinations that keep the reading between 10% and 100% torque.

03

Spindle and speed

Higher-viscosity samples generally require a smaller spindle and/or slower speed. Non-Newtonian samples can report different apparent viscosity when spindle or speed changes.

04

Temperature and container

Temperature, container diameter, sample volume, immersion depth and air bubbles affect results. State the controlled temperature and any small-sample limitation.

05

Accessories and records

List spindle set, stand, guard leg, temperature probe or bath, small-sample adapter, data export and calibration-standard needs. Compatibility is model-specific.

Include this in a viscometer request

  • Method or existing Brookfield setup
  • Expected viscosity range and units
  • Sample type and non-Newtonian behavior
  • Test temperature and sample volume
  • Required spindle, speed and accessories
  • Data output and calibration-check needs

Brookfield viscometer FAQ

How do I choose spindle and speed?

Use the combination required by the method when one exists. For an unknown sample, Brookfield recommends adjusting spindle and speed until the displayed torque is between 10% and 100%, then keeping the condition consistent for comparable tests.

Why does viscosity change when speed changes?

Many materials are non-Newtonian, so measured apparent viscosity depends on shear conditions. Report the spindle, speed, temperature and other test conditions with the result.

Can I compare results from different containers?

Container geometry can change the measurement, particularly with standard spindles. Use the specified container or document its dimensions and validate the method before comparing results.

Related measurement categories

Official Brookfield references

The test-condition and torque guidance comes directly from AMETEK Brookfield. Exact range and accessory compatibility are verified for the quoted model.

Results depend on the complete method and sample behavior. Never infer a suitable range, spindle or accessory from the product name alone; verify the current manual and range table.