We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

Viscometers & Accessories

Laboratory rotational viscometers and accessories for viscosity testing. Select by method, torque range, spindle, speed, temperature and sample volume.

TL;DR

AMETEK Brookfield and laboratory viscometers

We supply AMETEK Brookfield and other laboratory viscometers in Thailand, including the DVPLLV. A viscosity result is only comparable when the spindle, speed, temperature, container and sample preparation are stated with it. Every model is quoted on request.

507 products · page 2 of 9

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Magnetic Coupling with Ball Bearing, HB, Without Bluetooth XDVPLHBMB00C00

MX-14398

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Magnetic Coupling with Point & Jewel, HA, With Bluetooth XDVPLHAMJB0C00

MX-14932

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Magnetic Coupling with Point & Jewel, LV, With Bluetooth XDVPLLVMJB0U00

MX-14869

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Magnetic Coupling with Point & Jewel, LV, Without Bluetooth XDVPLLVMJ00C00

MX-14484

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Magnetic Coupling with Point & Jewel, RV, With Bluetooth XDVPLRVMJB0U00

MX-14871

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Magnetic Coupling with Point & Jewel, RV, Without Bluetooth XDVPLRVMJ00C00

MX-14602

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Ball Bearing, HB, With Bluetooth XDVPLHBTBB0C00

MX-14934

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Ball Bearing, RV, With Bluetooth XDVPLRVTBB0C00

MX-14939

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Ball Bearing, RV, Without Bluetooth XDVPLRVTB00C00

MX-14603

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Point & Jewel, LV, With Bluetooth XDVPLLVTJB0C00

MX-14936

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Point & Jewel, LV, With Bluetooth XDVPLLVTJB0U00

MX-14868

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Point & Jewel, LV, Without Bluetooth XDVPLLVTJ00C00

MX-14485

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Point & Jewel, RV, With Bluetooth XDVPLRVTJB0C00

MX-14941

No photo

AMETEK Brookfield

Brookfield DVPlus Viscometer, Threaded Coupling with Point & Jewel, RV, With Bluetooth XDVPLRVTJB0U00

MX-14870

No photo

AMETEK Brookfield

Brookfield GV-1098 Viscometer

MX-14378

No photo

AMETEK Brookfield

Brookfield HA Analog Master Visc, glass win,

MX-14381

No photo

AMETEK Brookfield

Brookfield HADV2T Viscometer,MAG,BB,

MX-14386

No photo

AMETEK Brookfield

Brookfield HADV2T Viscometer,MAG,PJ,

MX-14387

No photo

AMETEK Brookfield

Brookfield HADV2T Viscometer,TC,BB,

MX-14388

No photo

AMETEK Brookfield

Brookfield HADV2T Viscometer,TC,PJ,

MX-14389

No photo

AMETEK Brookfield

Brookfield HADVNX CP Rheometer,BB,ASIA

MX-14390

No photo

AMETEK Brookfield

Brookfield KU-3 Viscometer XKU3ASTKB00C00

MX-14434

No photo

AMETEK Brookfield

Brookfield KU-3 Viscometer XKU3ASTKB00U00

MX-14431

No photo

AMETEK Brookfield

Brookfield KU-3 Viscometer XKU3ASTKB00W00

MX-14435

No photo

AMETEK Brookfield

Brookfield KU3 Master Viscometer

MX-14433

No photo

AMETEK Brookfield

Brookfield LV Analog Master Visc, glass win,

MX-14463

No photo

AMETEK Brookfield

Brookfield LVDV2T Viscometer,GEL/T,TC,PJ,

MX-14472

No photo

AMETEK Brookfield

Brookfield LVDV2T Viscometer,MAG,PJ,

MX-14473

No photo

AMETEK Brookfield

Brookfield LVDV2T Viscometer,TC,PJ,

MX-14475

No photo

AMETEK Brookfield

Brookfield LVDV2T Viscometer,TC,PJ,WITHOUT

MX-14476

No photo

AMETEK Brookfield

Brookfield RV Analog Master Visc, glass win,

MX-14583

No photo

AMETEK Brookfield

Brookfield RVDV2T Viscometer,TC,PJ,WITHOUT

MX-14594

No photo

AMETEK Brookfield

Brookfield RVDVNX CP Rheometer,BB,ASIA

MX-14595

No photo

AMETEK Brookfield

Brookfield RVDVNX Rheometer,PJ - CP XDVNXRVCJG0U00

MX-14600

No photo

AMETEK Brookfield

Brookfield XDV2TB5TB0AC00 Viscometer

MX-14912

No photo

AMETEK Brookfield

Brookfield XDV2THATJ0AC00 Viscometer

MX-14913

No photo

AMETEK Brookfield

Brookfield XDV2TLVMJGGC00 Viscometer

MX-14914

No photo

AMETEK Brookfield

Brookfield XDV2TLVTJ0AC00 Viscometer

MX-14915

No photo

AMETEK Brookfield

Brookfield XDV2TRVMJGGU00 Viscometer

MX-14916

No photo

AMETEK Brookfield

Brookfield XDV2TRVTB0AC00 Viscometer

MX-14917

No photo

AMETEK Brookfield

Brookfield XDV2TRVTJ0AC00 Viscometer

MX-14918

No photo

AMETEK Brookfield

Brookfield XDVPLLVTJ0AC00 Viscometer

MX-14935

No photo

AMETEK Brookfield

Brookfield XDVPLLVTJBAC00 Viscometer

MX-14937

No photo

AMETEK Brookfield

Brookfield XDVPLRVMJ0AU00 Viscometer

MX-14938

No photo

AMETEK Brookfield

Brookfield XDVPLRVTJ0AC00 Viscometer

MX-14940

No photo

AMETEK Brookfield

Brookfield XDVPLRVTJBAC00 Viscometer

MX-14942

No photo

AMETEK Brookfield

DVPLLV Viscometer

MX-10351

No photo

AMETEK Brookfield

Brookfield #4 FLAT WASHER 18-8 SS

MX-14259

No photo

AMETEK Brookfield

Brookfield #8 FLAT WASHER 18-8SS

MX-14270

No photo

AMETEK Brookfield

Brookfield 1 Pint Can

MX-14248

No photo

AMETEK Brookfield

Brookfield 1" LONG SPINDLE EXTENSION

MX-14247

No photo

AMETEK Brookfield

Brookfield 18" Upright Rod VS-38

MX-14859

No photo

AMETEK Brookfield

Brookfield 2 OZ. TUBE NYEGEL #795

MX-14253

No photo

AMETEK Brookfield

Brookfield 2-56 EXTENDED BRISTOL WRENCH

MX-14250

Viscometer buying guide

How to choose a viscometer

01

Method or historical setup

If a specification or established test names the instrument, spindle and speed, reproduce that setup. This preserves comparability with earlier results and customer requirements.

02

Viscosity and torque range

Give the expected minimum and maximum viscosity. Brookfield guidance recommends choosing spindle and speed combinations that keep the reading between 10% and 100% torque.

03

Spindle and speed

Higher-viscosity samples generally require a smaller spindle and/or slower speed. Non-Newtonian samples can report different apparent viscosity when spindle or speed changes.

04

Temperature and container

Temperature, container diameter, sample volume, immersion depth and air bubbles affect results. State the controlled temperature and any small-sample limitation.

05

Accessories and records

List spindle set, stand, guard leg, temperature probe or bath, small-sample adapter, data export and calibration-standard needs. Compatibility is model-specific.

Include this in a viscometer request

  • Method or existing Brookfield setup
  • Expected viscosity range and units
  • Sample type and non-Newtonian behavior
  • Test temperature and sample volume
  • Required spindle, speed and accessories
  • Data output and calibration-check needs

Brookfield viscometer FAQ

How do I choose spindle and speed?

Use the combination required by the method when one exists. For an unknown sample, Brookfield recommends adjusting spindle and speed until the displayed torque is between 10% and 100%, then keeping the condition consistent for comparable tests.

Why does viscosity change when speed changes?

Many materials are non-Newtonian, so measured apparent viscosity depends on shear conditions. Report the spindle, speed, temperature and other test conditions with the result.

Can I compare results from different containers?

Container geometry can change the measurement, particularly with standard spindles. Use the specified container or document its dimensions and validate the method before comparing results.

Related measurement categories

Official Brookfield references

The test-condition and torque guidance comes directly from AMETEK Brookfield. Exact range and accessory compatibility are verified for the quoted model.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.