We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

Viscometers & Accessories

Laboratory rotational viscometers and accessories for viscosity testing. Select by method, torque range, spindle, speed, temperature and sample volume.

TL;DR

AMETEK Brookfield and laboratory viscometers

We supply AMETEK Brookfield and other laboratory viscometers in Thailand, including the DVPLLV. A viscosity result is only comparable when the spindle, speed, temperature, container and sample preparation are stated with it. Every model is quoted on request.

507 products · page 9 of 9

No photo

AMETEK Brookfield

Brookfield Vane Spindle #73 V-73

MX-14862

No photo

AMETEK Brookfield

Brookfield Vane Spindle #74 V-74

MX-14864

No photo

AMETEK Brookfield

Brookfield Vane Spindle #75 V-75

MX-14866

No photo

AMETEK Brookfield

Brookfield Vane Spindle, 10 mm Length, 5 mm Dia. VT-10-5

MX-14876

No photo

AMETEK Brookfield

Brookfield Vane Spindle, 30 mm Length, 15 mm Dia. VT-30-15

MX-14877

No photo

AMETEK Brookfield

Brookfield Vane Spindle, 40 mm Length, 20 mm Dia. VT-40-20

MX-14878

No photo

AMETEK Brookfield

Brookfield Vane Spindle, 50 mm Length, 25 mm Dia. VT-50-25

MX-14879

No photo

AMETEK Brookfield

Brookfield Vane Spindle, 60 mm Length, 30 mm Dia. VT-60-30

MX-14880

No photo

AMETEK Brookfield

Brookfield Vane Spindle, 80 mm Length, 70 mm Dia. VT-80-70

MX-14881

No photo

AMETEK Brookfield

Brookfield VISION GLASS SUPPORT K-4

MX-14875

No photo

AMETEK Brookfield

Brookfield VTA 100-5Y Viscometer

MX-14882

No photo

AMETEK Brookfield

Brookfield Water jacket assembly

MX-14883

No photo

AMETEK Brookfield

Brookfield WATER JACKET ASSEMBLY

MX-14885

No photo

AMETEK Brookfield

Brookfield YD-2 Viscometer

MX-14943

No photo

AMETEK Brookfield

Brookfield YD-8LV Viscometer

MX-14944

No photo

AMETEK Brookfield

Brookfield YSLJ-3 Viscometer

MX-14945

No photo

AMETEK Brookfield

Brookfield YULA-15EM Viscometer

MX-14946

No photo

AMETEK Brookfield

Wells/Brookfield Cone Spindle, 316 Stainless Steel, compliant CPA-40CZ

MX-14336

No photo

AMETEK Brookfield

Wells/Brookfield Cone Spindle, 316 Stainless Steel, compliant CPA-41CZ

MX-14338

No photo

AMETEK Brookfield

Wells/Brookfield Cone Spindle, 316 Stainless Steel, Standard CPA-40Z

MX-14337

No photo

AMETEK Brookfield

Wells/Brookfield Cone Spindle, 316 Stainless Steel, Standard CPA-41Z

MX-14339

No photo

AMETEK Brookfield

Wells/Brookfield Cone Spindle, 316 Stainless Steel, Standard CPA-42Z

MX-14340

No photo

AMETEK Brookfield

Wells/Brookfield Cup Assembly with RTD Temperature Probe, 316 Stainless Steel, with Cable CPA-44PYZ

MX-14342

No photo

AMETEK Brookfield

Wells/Brookfield Cup Assembly with RTD Temperature Probe, 316 Stainless Steel, without Cable CPA-44PSYZ

MX-14341

No photo

MST-CUP-TH Cup

MX-10739

Viscometer buying guide

How to choose a viscometer

01

Method or historical setup

If a specification or established test names the instrument, spindle and speed, reproduce that setup. This preserves comparability with earlier results and customer requirements.

02

Viscosity and torque range

Give the expected minimum and maximum viscosity. Brookfield guidance recommends choosing spindle and speed combinations that keep the reading between 10% and 100% torque.

03

Spindle and speed

Higher-viscosity samples generally require a smaller spindle and/or slower speed. Non-Newtonian samples can report different apparent viscosity when spindle or speed changes.

04

Temperature and container

Temperature, container diameter, sample volume, immersion depth and air bubbles affect results. State the controlled temperature and any small-sample limitation.

05

Accessories and records

List spindle set, stand, guard leg, temperature probe or bath, small-sample adapter, data export and calibration-standard needs. Compatibility is model-specific.

Include this in a viscometer request

  • Method or existing Brookfield setup
  • Expected viscosity range and units
  • Sample type and non-Newtonian behavior
  • Test temperature and sample volume
  • Required spindle, speed and accessories
  • Data output and calibration-check needs

Brookfield viscometer FAQ

How do I choose spindle and speed?

Use the combination required by the method when one exists. For an unknown sample, Brookfield recommends adjusting spindle and speed until the displayed torque is between 10% and 100%, then keeping the condition consistent for comparable tests.

Why does viscosity change when speed changes?

Many materials are non-Newtonian, so measured apparent viscosity depends on shear conditions. Report the spindle, speed, temperature and other test conditions with the result.

Can I compare results from different containers?

Container geometry can change the measurement, particularly with standard spindles. Use the specified container or document its dimensions and validate the method before comparing results.

Related measurement categories

Official Brookfield references

The test-condition and torque guidance comes directly from AMETEK Brookfield. Exact range and accessory compatibility are verified for the quoted model.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.