Skip to content
ไทย

Water Testing & Analysis

Dissolved oxygen, salinity, turbidity, chlorine and multiparameter meters for water analysis in labs, aquaculture and treatment plants.

Water analysis selection guide

Turn the water-testing requirement into a parameter-by-parameter order

A water-testing setup can combine sensors for pH, conductivity and dissolved oxygen with photometric tests for specific substances. List the result, expected range and required method for each parameter, then quote the instruments and the supplies that each method consumes.

See the checklist and buying questions

397 products · page 1 of 9

1 mL Graduated Syringe (10 pcs)

Hanna

1 mL Graduated Syringe

2 variants: 6 · 10

Choose a variant
10 ppm and 100 ppm Nitrate (as N) Calibration Standard Sachets for HI9829 (10 x 25 mL each)

Hanna

10 ppm and 100 ppm Nitrate (as N) Calibration Standard Sachets for HI9829 (10 x 25 mL each)

MX-11176

13mm Vials (5 pcs.)

Hanna

13mm Vials (5 pcs.)

MX-11180

7031 Pen-Type Dissolved Oxygen Meter

Ezdo

7031 Pen-Type Dissolved Oxygen Meter

MX-10414

Advanced Dissolved Oxygen Benchtop Meter

Hanna

Advanced Dissolved Oxygen Benchtop Meter

MX-11202

Advanced Free Chlorine Portable Photometer

Hanna

Advanced Free Chlorine Portable Photometer

MX-11557

Alkalinity CAL Check standard kit for HI97 series portable photometer

Hanna

Alkalinity CAL Check standard kit for HI97 series portable photometer

MX-11206

Aluminum Portable Photometer

Hanna

Aluminum Portable Photometer

MX-11208

Ammonia High Range Portable Photometer

Hanna

Ammonia High Range Portable Photometer

MX-11211

Ammonia Low Range CAL Check Standard

Hanna

Ammonia Low Range CAL Check Standard

MX-11214

Ammonia Low Range Portable Photometer

Hanna

Ammonia Low Range Portable Photometer

MX-11215

Ammonia Medium Range CAL Check Standards for HI97715

Hanna

Ammonia Medium Range CAL Check Standards for HI97715

MX-11218

Ammonia Medium Range Photometer

Hanna

Ammonia Medium Range Photometer

MX-11219

Reinigungsmittel anionisch – Reagenzien-Kit – 100 Tests

Hanna

Anionic Surfactant Reagent Kit – 100 Tests

MX-13203

Anionic Surfactants Portable Photometer

Hanna

Anionic Surfactants Portable Photometer

MX-11231

Aquaculture Photometer

Hanna

Aquaculture Photometer

MX-11232

Auger for Ground Penetration

Hanna

Auger for Ground Penetration

MX-11236

Boiler and Cooling Tower Photometer

Hanna

Boiler and Cooling Tower Photometer

MX-11272

Bromine Portable Photometer

Hanna

Bromine Portable Photometer

MX-11274

CAL Check Cuvette Kit for HI83303 Aquaculture Photometer

Hanna

CAL Check Cuvette Kit for HI83303 Aquaculture Photometer

MX-11276

CAL Check Cuvette Kit for HI83305 Boiler and Cooling Tower Photometer

Hanna

CAL Check Cuvette Kit for HI83305 Boiler and Cooling Tower Photometer

MX-11277

CAL Check Cuvette Kit for HI83306 Environmental Analysis Photometer

Hanna

CAL Check Cuvette Kit for HI83306 Environmental Analysis Photometer

MX-11278

CAL Check Cuvette Kit for HI83308 Water Conditioning Photometer

Hanna

CAL Check Cuvette Kit for HI83308 Water Conditioning Photometer

MX-11279

CAL Check Cuvette Kit for HI83325 Nutrient Analysis Photometer

Hanna

CAL Check Cuvette Kit for HI83325 Nutrient Analysis Photometer

MX-11280

CAL Check Cuvette Kit for HI83326 Pool and Spa Photometer

Hanna

CAL Check Cuvette Kit for HI83326 Pool and Spa Photometer

MX-11281

CAL Check Cuvette Kit for HI83399 Water & Wastewater Photometer

Hanna

CAL Check Cuvette Kit for HI83399 Water & Wastewater Photometer

MX-11282

CAL Check Standards for Marine Master Photometer – Cuvette Kit

Hanna

CAL Check Standards for Marine Master Photometer – Cuvette Kit

MX-11284

CAL Check™ standards for Chloride, 0.0 and 10.0 ppm

Hanna

CAL Check™ standards for Chloride, 0.0 and 10.0 ppm

MX-11283

Calcium & Magnesium Photometer

Hanna

Calcium & Magnesium Photometer

MX-11304

Calcium Hardness Checker® HC Calibration Check Set

Hanna

Calcium Hardness Checker® HC Calibration Check Set

MX-12309

Calcium Hardness Colorimeter - Checker®HC

Hanna

Calcium Hardness Colorimeter - Checker®HC

MX-12311

Calcium Hardness Portable Photometer

Hanna

Calcium Hardness Portable Photometer

MX-11303

Calibration Standard HI 700 Checker HC ®

Hanna

Calibration Standard HI 700 Checker HC ®

MX-11319

Calibration Standard HI 701 Checker HC ®

Hanna

Calibration Standard HI 701 Checker HC ®

MX-11320

Calibration Standard HI 705 Checker HC ®

Hanna

Calibration Standard HI 705 Checker HC ®

MX-11321

Calibration Standard HI 706 Checker HC ®

Hanna

Calibration Standard HI 706 Checker HC ®

MX-11322

Calibration Standard HI 707 Checker HC ®

Hanna

Calibration Standard HI 707 Checker HC ®

MX-11323

Calibration Standard HI 708 Checker HC ®

Hanna

Calibration Standard HI 708 Checker HC ®

MX-11324

Calibration Standard HI 711 Checker HC ®

Hanna

Calibration Standard HI 711 Checker HC ®

MX-11325

Calibration Standard HI 713 Checker HC ®

Hanna

Calibration Standard HI 713 Checker HC ®

MX-11326

Calibration Standard HI 715 Checker HC ®

Hanna

Calibration Standard HI 715 Checker HC ®

MX-11327

Calibration Standard HI 716 Checker HC ®

Hanna

Calibration Standard HI 716 Checker HC ®

MX-11328

Calibration Standard HI 717 Checker HC ®

Hanna

Calibration Standard HI 717 Checker HC ®

MX-11329

Calibration Standard HI 718 Checker HC ®

Hanna

Calibration Standard HI 718 Checker HC ®

MX-11330

Calibration Standard HI 721 Checker HC ®

Hanna

Calibration Standard HI 721 Checker HC ®

MX-11331

Calibration Standard HI 723 Checker HC ®

Hanna

Calibration Standard HI 723 Checker HC ®

MX-11332

Calibration Standard HI 726 Checker HC ®

Hanna

Calibration Standard HI 726 Checker HC ®

MX-11333

Calibration Standard HI 727 Checker HC ®

Hanna

Calibration Standard HI 727 Checker HC ®

MX-11334

Water analysis selection guide

Five decisions behind a water testing quote

01

Specify the result and reporting unit

Write free chlorine or total chlorine, not just chlorine. Include the expected minimum and maximum, reporting unit and decision limit from your method or customer requirement. For example, a value reported as a substance is not automatically interchangeable with a value reported as its constituent element.

02

Compare methods before model counts

Hanna HI97701 measures free chlorine over 0.00 to 5.00 mg/L as Cl₂. For a requirement covering both free and total chlorine, the manufacturer offers HI97711 with separate reagent choices. This illustrates why a quotation must name each result and reagent code, even when instrument ranges look alike.

03

Distinguish a sensor system from a photometer

The HI98494 listed in our catalog uses pH/ORP, conductivity and optical DO sensors. Its multiparameter label does not mean it performs the chlorine photometer methods above. Match every requested parameter to a documented channel, sensor or photometric method.

04

Count tests and replacement supplies

State monthly sample tests plus blanks, quality-control checks and repeats required by the method. For photometers, list reagent codes, pack sizes, cuvettes and storage limits. For sensor systems, include the relevant caps, maintenance solutions and replacement sensors. Compare total recurring requirements rather than assuming one cost always dominates.

05

Plan verification and procurement documents

Request model-specific check standards where appropriate. Hanna HI97701-11, for example, has a certificate carrying its lot, reference values and expiry. Keep a manufacturer quality certificate, a standard certificate and a separately requested calibration service as distinct quotation items. Specify site, cable length and record-export needs.

Include this in a water testing request

  • Each parameter, including free or total chlorine where relevant, and reporting units
  • Expected sample range and the decision limit or specification to assess
  • Required method, sample matrix and existing instrument or reagent codes
  • Monthly tests plus the blanks, controls and repeats in your procedure
  • Field or bench use, cable or sampling needs and output format
  • Reagents, check standards, replacement parts, certificates, quantity and delivery province

Common water testing questions

Can I request one instrument for all water parameters?

Start with a parameter matrix. A multiparameter sensor instrument and a multiparameter photometer support different techniques. Mark which device, sensor or method produces each required result before deciding whether one instrument is enough.

Can I use free-chlorine reagents to report total chlorine?

Only use the reagent and procedure specified for the result. Hanna lists HI93701-01 for free chlorine and HI93711-01 for total chlorine in its HI97711 reference guide. Similar packaging or a common instrument does not make the methods interchangeable.

Does a CAL Check standard replace the sample reagent?

No. A model-specific check standard verifies the instrument against a reference; the sample test still uses its stated reagent and procedure. Check which standards are included in the exact kit and which need separate ordering.

How should we compare running costs?

Compare the same workload and verification plan: tests per month, reagents per test, control and repeat use, expiry losses and replaceable sensor parts. Ask for an itemized supply list so a lower instrument price does not conceal an incomplete setup.

Related water bench equipment

Manufacturer methods and ordering references

These references support the named chlorine-method comparison, check-standard documents and sensor-system example. Verify the current model, method and kit supplied in Thailand before ordering.

This buying guide does not decide which method meets a legal or customer requirement. The laboratory must confirm the accepted method, sample suitability and reporting units; quoted ranges and consumables must match that choice.