The HI731325 are the replacement caps for glass cuvettes that are supplied with the HI93 series portable photometers and turbidity meters. The caps are designed to keep any stray light from entering the sample cuvette holder of the optically based system.
When using a photometer it is important to insert the cuvette in the same position when performing a blank measurement (zero) and a read with reacted sample in order to maintain a consistent path length in accordance with the Beer-Lambert Law (see below).
CheBI is optimized for Western blot research, using the highly efficient Cooling CCD Camera. Its compact size (24cm width x 24cm depth) helps make better use of a space in the laboratory. It’s exposure time can be set by the users manually or it can be calculated automatically.
Features : ◆ High chemical resistant All wetted parts of Chemker series pump are made of PTFE material which can resist most of corrosive gases. ◆ No air pollution, maintenance free Chemker series pumps are driven by Diaphragm, without the need of lubricant, regular oil changes and maintenance; with no oil pollution.
Features : ◆ High chemical resistant All wetted parts of Chemker series pump are made of PTFE material which can resist most of corrosive gases. ◆ No air pollution, maintenance free Chemker series pumps are driven by Diaphragm, without the need of lubricant, regular oil changes and maintenance; with no oil pollution.
The HI93755-53 is a chlorine remover reagent used to remove chlorine interference when performing a colorimetric determination for freshwater alkalinity with the HI775 Freshwater Alkalinity Colorimeter – Checker® HC.
Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.
Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.
-External size (WxDxH) 1100x750x2200 mm -Internal size (WxDxH) 940x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust.
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference…
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference…
CO2 Incubators The SHEL LAB CO2 Incubator family includes the following design features and the longest warranty period on the market – a five year limited warranty on most models: Infrared (IR) CO2 Sensor is extremely quick to recover CO2 levels after door openings and ensures superior pH stability Unique air…
Temperature Range: 30.0 to 170.0 °C (86 to 338 °F) *Reactor displays outside temperature range of 20 - 30 °C (68 - 86 °F) and 170 - 180 °C (338 - 356 °F) Values below 20 °C (68 °F) and above 180 °C (356 °F) are not displayed.
The 570 is designed with all solid state circuitry, and the pressure sensor system provides uniform sensitivity over the whole of working field; suitable for counting bacteria growing on all agar contained in different size of petri dishes.
Co-using Angle & Swing rotor, Ergonomically arranged and designed, RPM/RCF auto calculating, Changing term of timer during operation, memory for saving experiment condition, BLDC Motor, Easy to keypad, Compact design
Co-using Angle & Swing rotor, Ergonomically arranged and designed, RPM/RCF auto calculating, Changing term of timer during operation, memory for saving experiment condition, Fast Cooling, AC induction Motor Cooling System, Lid latch by motor preventing imbalance of sample.
EC Range: 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
-Intelligent temperature controller, based on microprocessor with PID parameters controlling function, and digital display make temperature accurate and reliable.