Reagents, media and everyday consumables on one shelf: Merck and RCI-Labscan solvents and analytical-grade chemicals, Merck and Difco culture media (Nutrient Agar, PCA, PDA, TSA), Mettler Toledo and Eutech pH buffers, KCl electrolyte and conductivity standards, ITS and V-unique chlorine and hardness test kits, plus Axygen, Capp and Nichiryo tips, microtubes, Petri dishes and Whatman filter paper. Restock alongside instrument and glassware orders on a single quotation — free, with a fast response.
Consumables programme
One quotation for every brand on the bench
Consumables burn budget in small, frequent orders spread across suppliers. Send the whole list — catalogue numbers or specifications, any mix of brands — and it comes back as one quotation, one delivery and one tax invoice.
The HI93711-D3 are high quality liquid reagents that allow for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.
A gas-trap tube, or Durham tube, is generally used in biology experiments to monitor gas produced by micro-organisms. The tube is placed upside down inside a larger test tube; at the start of the experiment a growth medium in which the micro-organisms can grow is added to the Durham tube, which is then incubated in an incubator.
Agarose gels are often run to check and see if a band is present or not, for example in a PCR reaction. With 5 regularly spaced bands, ranging from 100 bp to 2000 bp, EasyLadder™ I is a molecular weight marker especially designed for fast size determination of linear double-stranded DNA fragments on 0.5% to 3%…
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference…
The HI740157P electrode refilling pipettes allow for safe, convenient, and precise transfer of electrolyte fill solution into refillable Hanna electrodes.
The HI7072L 1M KNO3 (potassium nitrate) electrode fill solution is chloride free. It is mainly used as a reference fill solution for Bromide, Cadmium, Chloride, Cupric, Cyanide, Iodide, Lead/Sulfate, and Silver/Sulfide electrodes.
pH and ORP electrodes are available with a single junction or double junction reference cell. The single junction reference electrode is made with a silver (Ag) wire coated with silver chloride (AgCl). This wire is in contact with the sample to be measured by a fill solution that leaks through a junction.
The electrolyte level in refillable electrodes should be checked before performing any measurement. If the level is low, refill with the proper electrolyte solution to ensure the correct electrode performance.
Pure alcohol 95% by volume (Ethyl Alcohol 95% v/v) made from natural raw materials; a clear, colourless liquid with a low level of impurities. Complies with TIS 640-2553 Volume 1, ethanol for pharmaceutical use, and TIS 640-2553 Volume 2, ethanol for industrial use, and is safe for users.
Pure alcohol 95% by volume (Ethyl Alcohol 95% v/v), pack size 450 ml. Made from natural raw materials; a clear, colourless liquid with a low level of impurities. Complies with TIS 640-2553 Volume 1, ethanol for pharmaceutical use, and TIS 640-2553 Volume 2, ethanol for industrial use, and is safe for users.
Pure alcohol 99.8% by volume (Ethyl Alcohol 99.8% v/v) made from natural raw materials; a clear, colourless liquid with a low level of impurities. Complies with TIS 640-2553 Volume 1, ethanol for industrial use in pharmaceuticals, food and other applications, and is safe for users.
Absolute ethanol, 99.9% pure, 2.5 litre. A premium grade with purity up to 99.99%, suitable for high-precision laboratory analysis, meeting ACS/ISO standards and the European Pharmacopoeia analytical reagent standard (Reag. Ph Eur).
A qualitative filter paper, the most widely used type in the general laboratory. It is commonly used to clarify liquids and to separate precipitates of chemicals such as lead sulfate, calcium oxalate and calcium carbonate. It is also used in other industries, for example in agriculture for soil and seed analysis, or to collect airborne dust for air pollution analysis.
Pipette tips, 10 µl, filter type; Made of Polypropylene (PP) plastic; Certified RNase, DNase, and endotoxin free; Supplied in a PP box, already sterilised (Sterile)
Pipette tips, 100 µl, filter type; Made of Polypropylene (PP) plastic; Certified RNase, DNase, and endotoxin free; Supplied in a PP box, sterile; Internal tip slots, 96 tips per box
Pipette tips, 20 µl, filter type; Made of Polypropylene (PP) plastic, Certified RNase, DNase, and endotoxin free; Supplied in a PP box, sterile; Internal tip slots, 96 tips per box
Pipette tips, 200 µl, filter type; Made of Polypropylene (PP) plastic; Certified RNase, DNase, and endotoxin free; Supplied in a PP box, sterile; Internal tip slots, 96 tips per box
The HI93739-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of EPA method 340.1 and the SPADNS method. The reaction between fluoride and the reagent causes a color change in the sample.
The HI93729-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the EPA method 340.1 and SPADNS method. The reaction between fluoride and the reagent causes a color change in the sample.
HI70701M is a 1 g/L standard solution of fluoride used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.
HI70701/1L is a 1 g/L standard solution of fluoride used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.
HI70702/1L is a 10 mg/L standard solution of fluoride used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.
HI70702M is a 10 mg/L standard solution of fluoride used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.
Consumables programme
Five details that make a consumables quote exact
01
Catalogue number or specification
A manufacturer catalogue number is exact. Where there is none, give the specification that matters: material, size or volume, graduation, sterility, colour code. Mark which items accept an equivalent brand and which must not change.
02
Pack size and unit of issue
Tips come by rack and by case; gloves by box and by carton. Consumables requests fail on units more than on anything else — state the quantity, the unit you count in, and the pack format you want delivered.
03
Grade and sterility
Reagent grade (AR, ACS, HPLC), glass class A or B, sterile or non-sterile, powdered or powder-free: one product name spans several price points. Name the grade your method actually requires.
04
Documentation per lot
If your QA system needs certificates of analysis, expiry dating or lot traceability, say so in the request — it can decide which manufacturer we quote.
05
Reorder cadence
Tell us what repeats and how often. A recurring list is priced once and re-confirmed on each order, so a monthly top-up is one email rather than a new procurement round.
Include this in a consumables request
Catalogue numbers, or the governing spec where there is none
Quantity with its unit — each, pack, box or case
Grade, sterility and material requirements
Which lines accept equivalent brands
Documents needed: COA, lot data, delivery schedule
Items beyond the catalogue — we source on request
Consumables supply questions
Can you supply items that are not in the catalogue?
Yes. The published catalogue is a sample of what we supply, not the limit. Send the catalogue number or specification and it is quoted through our sourcing network like any other line.
Do you substitute brands?
Never silently. We quote the brand you name; where an equivalent offers a better price or lead time we may add it as a separately marked alternative line, and the choice stays with you.
How does repeat ordering work?
Send the list once. Each reorder re-confirms price against the same list, and every order ships with a full tax invoice (ใบกำกับภาษี). Registered business customers can apply for credit terms.