Water & environmental testing
Municipal, industrial and environmental water work — COD, BOD, turbidity, residual chlorine and heavy metals. Test kits and reagents carry the routine; meters and photometers are the occasional capital line.
46 products · page 1 of 2

V-unique
0300 Hardness Test Kit, Range 0-300 mg/l
MX-11023
Suitable for ordinary hard water not exceeding 300 mg/l, for checking and controlling water hardness — for example in cooling water systems, paper manufacturing, the weaving industry and dyeing.

V-unique
0525 Water Hardness Test Kit, Range 0-25 mg/l
MX-11024
Suitable for mildly hard water; for checking and controlling water hardness, for example in cooling water systems, paper manufacturing and the weaving industry.

V-unique
4590 pH Test Kit 4.5-9.0
MX-11025
For measuring pH in various industries including food, beverage, textile and cosmetics, and for checking the acidity and alkalinity of raw water sources and wastewater treatment ponds.

V-unique
9720 Free Chlorine Test Kit, Range 0.15-2.00 mg/l
MX-11026
Suitable for measuring chlorine in aquaculture water, including ornamental fish keeping, and also usable in various industries such as food, beverages, hospitals, and shrimp and poultry farms.

V-unique
9725 Chlorine Test Kit 0.1-8.0 mg/l
MX-11027
Suitable for measuring chlorine in aquaculture water, including ornamental fish keeping, and also usable in various industries such as food, beverages and hospitals.

V-unique
9730 Nitrite Test Kit 0.02-1.0
MX-11028
Nitrite in water comes from the decay of organic matter. It is absorbed into aquatic animals through the gills and reacts with haemoglobin in the blood, preventing oxygen transport, causing blood disorders and possibly killing the animals. A nitrite reading above 0.5 mg/l is considered fairly dangerous.

V-unique
9740 Alkalinity Test Kit
MX-11029
Measures the alkalinity of water. At a suitable level, alkalinity acts as a buffer that keeps pH from changing quickly; low alkalinity lets pH change rapidly, which can endanger aquatic animals. Suitable for testing water in swimming pools, shrimp farms, aquatic plant cultivation and water used in various industries.

V-unique
9750 Ammonium Test Kit 0-10 mg/l
MX-11030
Ammonia matters in aquaculture because it is both a toxin for aquatic animals and a fertiliser for phytoplankton growth. At high concentrations it is dangerous to aquatic animals; in culture ponds most ammonia comes from the animals' excretion and leftover feed.

V-unique
9780 Dissolved Oxygen Test Kit
MX-11031
Dissolved oxygen is an indicator of water quality and is important for aquatic animals and plants; too little oxygen in the water can be harmful to them.

Wheaton
BOD Bottle #227497 300ml., Wheaton
MX-10811
Glass bottle for BOD analysis in water, wastewater or effluent to American Public Health Association standards; Glass bottle for storing reagents or water samples for analysis

Merck
Lauryl sulfate broth (LSB) #110266, Merck
MX-11144
Lauryl sulfate broth (LSB) is widely used to detect coliform bacteria in wastewater, dairy products, other food products and clinical samples. It is a cream-yellow, homogeneous, free-flowing powder that dissolves readily in water at 25 °C, pH 6.8 ± 2.

Difco
Lauryl sulfate broth (Tryptose) #224150, Difco, BBL™
MX-11125
Pack size 500 g. Bacto™ Tryptone is used in preparing microbiological culture media. Ingredients, where noted, meet United States Pharmacopeia (USP) performance specifications.

Merck
Plate Count Agar (PCA) #105463, Merck
MX-11145
Plate count agar (PCA) culture medium is used for total microbial count testing of samples such as food, drinking water and other sample types. This medium complies with EN ISO 4833, ISO 17410, FDA-BAM and APHA.

Difco
Plate count agar #247940 Difco, BBL™
MX-11128
Pack size 500 g. Plate Count Agar and Standard Methods Agar (Plate Count Agar; Tryptone Glucose Yeast Agar) are used for obtaining microbial plate counts from milk and dairy products, foods, water and other materials of sanitary importance.

Lovibond
194150 Turbidity Standard Kit
MX-10742
ขนาด 0.1, 20, 200 และ 800 NTU อย่างละ 1 ขวด/ชุด สำหรับ รุ่น TB210IR ยี่ห้อ Lovibond

Lovibond
197620 Round Vial with Lid
MX-10197
ขวดเปล่าพร้อมฝาปิด ความสูง (Hight) 48 mm เส้นผ่านศูนย์กลาง Ø 24 mm สำหรับใช้กับเครื่องรุ่น MD200 / Lovibond

Lovibond
197655 Sample Vial with Black Lid
MX-10177
ขวดเปล่าสำหรับใส่ตัวอย่างพร้อมฝาปิด ขนาดเส้นผ่าศูนย์กลาง Dia 24 มม สำหรับใช้กับเครื่องรุ่น TB211IR / Lovibond

Lovibond
275650 Chlorine Reference Standard Kit
MX-10256
น้ำยาคลอรีนมตรฐาน Reference Standard Kit Chlorine ใน 1 ชุดมี 3 ขนาดคือ 0, 0.2 และ 1.0 mg/l สำหรับเครื่องรุ่น MD100, MD110, MD200

Lovibond
275655 Chlorine Reference Standard Kit
MX-10257
น้ำยาคลอรีนมตรฐาน Reference Standard Kit Chlorine ใน 1 ชุดมี 3 ขนาดคือ 0, 0.5 และ 2.0 mg/l สำหรับเครื่องรุ่น MD100, MD110, MD200

Lovibond
275656 Chlorine Reference Standard Kit
MX-10258
น้ำยาคลอรีนมตรฐาน Reference Standard Kit Chlorine ใน 1 ชุดมี 3 ขนาดคือ 0, 1.0 และ 4.0 mg/l สำหรับเครื่องรุ่น MD100, MD110, MD200

Indigo
33815-200 Chlorine Test Paper
MX-10221
สำหรับวัดค่าคลอรีนในน้ำ Total Chlorine ใช้คลอรีนได้ 4 ค่า คือที่ 10, 50, 100, 200 ppm มีจำนวน 100 ชิ้น/กล่อง

ITS
480008 Total Hardness Test Strips
MX-10271
กระดาษวัดค่าTotal Hardness ของสารละลาย 0-1000ppm วัดได้ที่ 0, 40, 80, 120, 180, 250, 425, 1000 ppm หรือ 0, 2, 5, 7, 11, 15, 25, 58 gpg ใช้เวลาเพียง 3 วินาที 1 กล่อง มีแถบวัด 50 ก้าน

ITS
480009 Nitrate and Nitrite Test Strips
MX-10272
กระดาษวัดค่าปริมาณ Nitrate 0-50ppm/Nitrite 0-10ppm วัดค่า Nitrate 0, 0.5, 2, 5, 10, 20, 50 ppm(mg/l) วัดค่า Nitrite ได้แก่ 0, 0.15, 0.3, 1, 1.5, 3, 10 ppm ใช้เวลาเพียง 1 นาที 1 กล่อง มีแถบวัด 50 ก้าน

ITS
480022 Free Chlorine High Test Strips
MX-10267
กระดาษทดสอบค่าปริมาณ Free chlorine 0-120ppm วัดค่าได้ที่ 0, 1, 5, 10, 20, 30, 40, 80, 120 ppm (mg/l) ใช้เวลาในการทดสอบเพียง 32 วินาที 1 กล่อง มีแถบวัด 50 ก้าน