Skip to content
ไทย

pH meter

pH, conductivity and TDS meters only — pen, portable and benchtop — from Ohaus (ST20, ST300, AB23PH-F, AB33EC-F), Mettler Toledo FiveEasy F20 and FiveGo F2, Eutech PH1710 and CON150, Hanna, Bante and HM Digital, plus Takemura and Rapitest soil testers. Buffers and electrolyte solutions sit under Consumables & Reagents, replacement electrodes under Electrodes & Probes. Free quotation, fast reply.

Buyer guide

Choose the meter, sensor and standards as one measurement system

For a Thai QC laboratory or production team, a useful quotation names the meter, compatible sensor and calibration supplies together. Start with the sample and acceptance requirement, then compare range, uncertainty or accuracy specifications, and the records your method needs.

See the checklist and buying questions

39 products

AB33PH-B+ST310 Benchtop pH Meter

Ohaus

AB33PH-B+ST310 Benchtop pH Meter

MX-10265

AP-1 Pen-Type TDS Meter

HM Digital

AP-1 Pen-Type TDS Meter

MX-10194

Bante220-CN Portable pH Meter

Bante

Bante220-CN Portable pH Meter

MX-10712

COM-100 Pen-Type Conductivity/TDS Meter

HM Digital

COM-100 Pen-Type Conductivity/TDS Meter

MX-10499

COM-300 Multi-Parameter pH/Conductivity Meter

HM Digital

COM-300 Multi-Parameter pH/Conductivity Meter

MX-10191

COM-80 Pen-Type Conductivity/TDS Meter

HM Digital

COM-80 Pen-Type Conductivity/TDS Meter

MX-10192

CON150 Portable Conductivity and TDS Meter

Eutech

CON150 Portable Conductivity and TDS Meter

MX-10769

FiveEasy pH F20 + LE438 Benchtop pH Meter

Mettler Toledo

FiveEasy pH F20 + LE438 Benchtop pH Meter

MX-10052

FiveGO Conductivity F3 Portable Conductivity Meter

Mettler Toledo

FiveGO Conductivity F3 Portable Conductivity Meter

MX-10409

FiveGo pH F2 + LE438 Portable pH Meter

Mettler Toledo

FiveGo pH F2 + LE438 Portable pH Meter

MX-10321

HI 98103 Portable pH Tester

Hanna

HI 98103 Portable pH Tester

MX-10334

HI2002 pH/ORP Benchtop Meter

Hanna

HI2002 pH/ORP Benchtop Meter

MX-10302

HI8314 Portable pH Meter

Hanna

HI8314 Portable pH Meter

MX-10301

Marine Low Range Nitrite Meter – HI767

Hanna

Marine Low Range Nitrite Meter – HI767

MX-12443

Marine pH Meter – HI780

Hanna

Marine pH Meter – HI780

MX-13082

PH-200 Handheld pH Meter

HM Digital

PH-200 Handheld pH Meter

MX-10498

PH-80 Handheld pH Meter

HM Digital

PH-80 Handheld pH Meter

MX-10748

PH450 Portable pH/mV/Ion Meter with Epoxy Electrode

Eutech

PH450 Portable pH/mV/Ion Meter with Epoxy Electrode

MX-10771

Pool and Spa ORP Controller and Dosing Pump

Hanna

Pool and Spa ORP Controller and Dosing Pump

MX-13015

Pool and Spa pH Controller and Dosing Pump

Hanna

Pool and Spa pH Controller and Dosing Pump

MX-13054

Portable Field pH Meter for Drinking Water – HI99192

Hanna

Portable Field pH Meter for Drinking Water – HI99192

MX-12927

ST20 Handheld pH Meter

Ohaus

ST20 Handheld pH Meter

MX-10416

ST20C-C Pen-Type Conductivity Meter

Ohaus

ST20C-C Pen-Type Conductivity Meter

MX-10417

ST20M-C Multi-Parameter pH/Conductivity Meter

Ohaus

ST20M-C Multi-Parameter pH/Conductivity Meter

MX-10418

ST300 Portable pH Meter

Ohaus

ST300 Portable pH Meter

MX-10606

ST300C Portable Conductivity/TDS Meter

Ohaus

ST300C Portable Conductivity/TDS Meter

MX-10626

Swimming Pool and Spa Controllers with Analog Outputs

Hanna

Swimming Pool and Spa Controllers with Analog Outputs

MX-13261

Swimming Pool and Spa Controllers with No Analog Outputs

Hanna

Swimming Pool and Spa Controllers with No Analog Outputs

MX-13260

Swimming Pool Controllers for pH Disinfection and Control

Hanna

Swimming Pool Controllers for pH Disinfection and Control

MX-11246

TDS-3 Pen-Type TDS Meter

HM Digital

TDS-3 Pen-Type TDS Meter

MX-10193

Buyer guide

Five decisions to make before comparing models

01

Parameters, units and expected range

List pH and conductivity separately, including the expected range in µS/cm or mS/cm. If reporting TDS, record the conversion factor required by your method. A conductivity-derived TDS result does not identify individual dissolved substances.

02

Match the sample to the sensor

Give the sample type, temperature and container dimensions, plus the existing meter and connector if replacing a probe. A milk sample, a viscous product and low-conductivity water can need different sensor designs. Confirm the exact electrode and meter combination before ordering.

03

A catalog example: HI98130

The Hanna HI98130 listed in our catalog combines pH, EC, TDS and temperature. Its EC range is 0.00 to 20.00 mS/cm with 0.01 mS/cm resolution. That resolution equals 10 µS/cm, so a buyer needing finer low-conductivity readings should specify that requirement before choosing this high-range tester.

04

Budget for the calibration supplies

Choose buffers that cover the expected sample pH and that the meter recognizes. Include the required conductivity standard, electrode storage and cleaning solutions, and replacement-sensor needs. Ask for lot, expiry and certificates where required; an included starter sachet is not a recurring supply plan.

05

Field use, records and receipt

Specify portable or benchtop use, cable length, power and the output format you need. Ask the quotation to separate the instrument, sensor, standards and any calibration service. On receipt, check the model and kit suffix, included items and relevant certificates against the order.

Include this in the quote request

  • Sample or process, expected pH and conductivity range, and measurement temperature
  • Required resolution and accuracy specification, units and any TDS conversion factor
  • Existing meter model, sensor part number and connector, or a complete new system
  • Portable or benchtop use, container size, cable length and data-export needs
  • Buffers, conductivity standards, storage and cleaning solutions; required certificates
  • Quantity, delivery province, required-by date and procurement reference or TOR if used

Common pH and conductivity meter questions

Does 0.01 pH resolution mean ±0.01 pH accuracy?

No. Resolution is the displayed increment. For example, Hanna specifies 0.01 pH resolution and ±0.05 pH accuracy at 25 °C for HI98130. Compare both values and the conditions stated by the manufacturer against your method.

Can one instrument measure both pH and conductivity?

Yes, some models can. HI98130 is one catalog example, but the required ranges and sensor suitability still decide whether it fits. A combined tester does not make every pH electrode or conductivity application interchangeable.

Is a TDS reading the same as a chemical analysis of the water?

No. On a conductivity-based tester, TDS is calculated using a conversion factor. Document that factor when comparing results across instruments; use the relevant analytical method when you need the concentration of a particular substance.

Which buffers and accessories should appear in the quotation?

Request buffers that bracket the sample range and match the meter settings, the specified EC standard where needed, and suitable storage and cleaning solutions. State required pack sizes and certificates. Confirm the exact kit contents rather than assuming a meter includes a full year of consumables.

Continue the measurement setup

Official selection references

The HI98130 example follows its manufacturer specification. The buffer-selection references explain calibration range and solution care; the quoted sensor and method still determine the final setup.

This guide helps define a quotation. It does not replace your laboratory method, quality procedure or the current instructions for the selected instrument and sensor.