Skip to content
ไทย

pH meter

pH, conductivity and TDS meters only — pen, portable and benchtop — from Ohaus (ST20, ST300, AB23PH-F, AB33EC-F), Mettler Toledo FiveEasy F20 and FiveGo F2, Eutech PH1710 and CON150, Hanna, Bante and HM Digital, plus Takemura and Rapitest soil testers. Buffers and electrolyte solutions sit under Consumables & Reagents, replacement electrodes under Electrodes & Probes. Free quotation, fast reply.

Buyer guide

Choose the meter, sensor and standards as one measurement system

For a Thai QC laboratory or production team, a useful quotation names the meter, compatible sensor and calibration supplies together. Start with the sample and acceptance requirement, then compare range, uncertainty or accuracy specifications, and the records your method needs.

See the checklist and buying questions

48 products

Beer pH Tester

Hanna

Beer pH Tester

MX-11242

Calibration Bundle for Beer (Bottles)

Hanna

Calibration Bundle for Beer (Bottles)

MX-11307

Calibration Bundle for Beer (Sachets)

Hanna

Calibration Bundle for Beer (Sachets)

MX-11308

Calibration Bundle for Cheese

Hanna

Calibration Bundle for Cheese

MX-11309

Calibration Bundle for Dairy

Hanna

Calibration Bundle for Dairy

MX-11310

Calibration Bundle for Food (Bottles)

Hanna

Calibration Bundle for Food (Bottles)

MX-11311

Calibration Bundle for Food (Sachets)

Hanna

Calibration Bundle for Food (Sachets)

MX-11312

Calibration Bundle for Meat

Hanna

Calibration Bundle for Meat

MX-11314

Calibration Bundle for Wine (Bottles)

Hanna

Calibration Bundle for Wine (Bottles)

MX-11316

Calibration Bundle for Wine (Sachets)

Hanna

Calibration Bundle for Wine (Sachets)

MX-11317

edge® Wine pH Meter (kit)

Hanna

edge® Wine pH Meter (kit)

MX-11717

FC100B – pH Elektrode

Hanna

FC100B – pH Electrode, PVDF (Fresh Cheese)

MX-11495

FC210B – pH Elektrode

Hanna

FC210B – pH Electrode, Glass (Dairy Products, Creams)

MX-11503

FC220B – pH Elektrode

Hanna

FC220B – pH Electrode, Glass (Creams, Fruit Juice, Sauces)

MX-11506

FC230B – FoodCare combined pH electrode, PVDF (meat, semi-frozen products)

Hanna

FC230B – FoodCare combined pH electrode, PVDF (meat, semi-frozen products)

MX-11507

FC240B – pH Elektrode

Hanna

FC240B – pH Electrode, AISI 316 Stainless Steel (Cheese, Dairy)

MX-11512

FC250B – pH Elektrode

Hanna

FC250B – pH Electrode, Glass (Semi-Solid Cheese)

MX-11513

FC400B – Foodcare pH-Elektrode, PVDF (Fleisch),

Hanna

FC400B – Foodcare pH Electrode, PVDF (Meat)

MX-11517

FC911B – Foodcare pH Elektrode – (cremige Proben, Fruchtsäfte)

Hanna

FC911B – Foodcare pH Electrode (Creamy Samples, Fruit Juices)

MX-11518

HALO2 Wireless pH Tester for Beer

Hanna

HALO2 Wireless pH Tester for Beer

MX-11626

HALO2 Wireless pH Tester for Cheese

Hanna

HALO2 Wireless pH Tester for Cheese

MX-11624

HALO2 Wireless pH Tester for Meat

Hanna

HALO2 Wireless pH Tester for Meat

MX-11631

HALO2 Wireless pH Tester for Meat with Built-in Specialized Electrode

Hanna

HALO2 Wireless pH Tester for Meat with Built-in Specialized Electrode

MX-11627

HALO2 Wireless pH Tester for Milk

Hanna

HALO2 Wireless pH Tester for Milk

MX-11632

HALO2 Wireless pH Tester for Sushi

Hanna

HALO2 Wireless pH Tester for Sushi

MX-11636

HALO2 Wireless Refillable pH Tester for Wine

Hanna

HALO2 Wireless Refillable pH Tester for Wine

MX-11641

HI1048x – pH-Elektrode, Glas, BNC, 1 m Kabel (Wein und Most)

Hanna

HI1048x – pH Electrode, Glass, BNC, 1 m Cable (Wine and Must)

MX-11653

Meat pH Tester with Built-in Specialized Electrode

Hanna

Meat pH Tester with Built-in Specialized Electrode

MX-12981

PAL-PH PLUS pH Meter

Atago

PAL-PH PLUS pH Meter

MX-10428

pH Meter for Milk Samples – HI981034

Hanna

pH Meter for Milk Samples – HI981034

MX-12831

pH Meter for Wine – HI99111

Hanna

pH Meter for Wine – HI99111

MX-13316

Portable Field pH Meter for Cheese – HI98165

Hanna

Portable Field pH Meter for Cheese – HI98165

MX-13051

Portable Field pH Meter for Cheese – HI99165

Hanna

Portable Field pH Meter for Cheese – HI99165

MX-13052

Portable Field pH Meter for Meat – HI98163

Hanna

Portable Field pH Meter for Meat – HI98163

MX-12866

Portable Field pH Meter for Meat – HI99163

Hanna

Portable Field pH Meter for Meat – HI99163

MX-12980

Portable Milk pH Meter

Hanna

Portable Milk pH Meter

MX-13136

Portable pH Meter for Brewing

Hanna

Portable pH Meter for Brewing

MX-12921

Portable pH Meter for Cheese – HI981032

Hanna

Portable pH Meter for Cheese – HI981032

MX-12830

Portable pH Meter for Food and Dairy

Hanna

Portable pH Meter for Food and Dairy

MX-12922

Portable pH Meter for Meat – HI981036

Hanna

Portable pH Meter for Meat – HI981036

MX-12832

Portable Yogurt pH Meter

Hanna

Portable Yogurt pH Meter

MX-12923

Professional pH Meter for Wine

Hanna

Professional pH Meter for Wine

MX-13150

Professional Portable Beer pH Meter

Hanna

Professional Portable Beer pH Meter

MX-13151

Professional Portable Milk pH Meter

Hanna

Professional Portable Milk pH Meter

MX-12865

Professional Portable Yogurt pH Meter

Hanna

Professional Portable Yogurt pH Meter

MX-12867

Stainless Steel Blade for Meat pH Testers, Compatible with HI9810452 and HI981045

Hanna

Stainless Steel Blade for Meat pH Testers, Compatible with HI9810452 and HI981045

MX-13248

Sushi pH Tester HI981035

Hanna

Sushi pH Tester HI981035

MX-13258

Wine pH Tester

Hanna

Wine pH Tester

MX-13317

Buyer guide

Five decisions to make before comparing models

01

Parameters, units and expected range

List pH and conductivity separately, including the expected range in µS/cm or mS/cm. If reporting TDS, record the conversion factor required by your method. A conductivity-derived TDS result does not identify individual dissolved substances.

02

Match the sample to the sensor

Give the sample type, temperature and container dimensions, plus the existing meter and connector if replacing a probe. A milk sample, a viscous product and low-conductivity water can need different sensor designs. Confirm the exact electrode and meter combination before ordering.

03

A catalog example: HI98130

The Hanna HI98130 listed in our catalog combines pH, EC, TDS and temperature. Its EC range is 0.00 to 20.00 mS/cm with 0.01 mS/cm resolution. That resolution equals 10 µS/cm, so a buyer needing finer low-conductivity readings should specify that requirement before choosing this high-range tester.

04

Budget for the calibration supplies

Choose buffers that cover the expected sample pH and that the meter recognizes. Include the required conductivity standard, electrode storage and cleaning solutions, and replacement-sensor needs. Ask for lot, expiry and certificates where required; an included starter sachet is not a recurring supply plan.

05

Field use, records and receipt

Specify portable or benchtop use, cable length, power and the output format you need. Ask the quotation to separate the instrument, sensor, standards and any calibration service. On receipt, check the model and kit suffix, included items and relevant certificates against the order.

Include this in the quote request

  • Sample or process, expected pH and conductivity range, and measurement temperature
  • Required resolution and accuracy specification, units and any TDS conversion factor
  • Existing meter model, sensor part number and connector, or a complete new system
  • Portable or benchtop use, container size, cable length and data-export needs
  • Buffers, conductivity standards, storage and cleaning solutions; required certificates
  • Quantity, delivery province, required-by date and procurement reference or TOR if used

Common pH and conductivity meter questions

Does 0.01 pH resolution mean ±0.01 pH accuracy?

No. Resolution is the displayed increment. For example, Hanna specifies 0.01 pH resolution and ±0.05 pH accuracy at 25 °C for HI98130. Compare both values and the conditions stated by the manufacturer against your method.

Can one instrument measure both pH and conductivity?

Yes, some models can. HI98130 is one catalog example, but the required ranges and sensor suitability still decide whether it fits. A combined tester does not make every pH electrode or conductivity application interchangeable.

Is a TDS reading the same as a chemical analysis of the water?

No. On a conductivity-based tester, TDS is calculated using a conversion factor. Document that factor when comparing results across instruments; use the relevant analytical method when you need the concentration of a particular substance.

Which buffers and accessories should appear in the quotation?

Request buffers that bracket the sample range and match the meter settings, the specified EC standard where needed, and suitable storage and cleaning solutions. State required pack sizes and certificates. Confirm the exact kit contents rather than assuming a meter includes a full year of consumables.

Continue the measurement setup

Official selection references

The HI98130 example follows its manufacturer specification. The buffer-selection references explain calibration range and solution care; the quoted sensor and method still determine the final setup.

This guide helps define a quotation. It does not replace your laboratory method, quality procedure or the current instructions for the selected instrument and sensor.