We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

Water Testing & Analysis

Dissolved oxygen, salinity, turbidity, chlorine and multiparameter meters for water analysis in labs, aquaculture and treatment plants.

TL;DR

Water testing instruments, reagents and refills

We supply water testing instruments in Thailand, including Hanna HI97701 and HI97711 chlorine photometers and DO, turbidity and multiparameter meters. Reagent refills and replacement cuvettes can be ordered alone with the meter model and item code. Every item is quoted on request.

399 products · page 4 of 7

HI731318 – Cuvette Cleaning Cloth (4 pcs)

Hanna

HI731318 – Cuvette Cleaning Cloth (4 pcs)

MX-12325

HI731321 – Glass Cuvette 4 pcs. – Photometer Series HI 937xx, HI 832xx und HI 7xx

Hanna

HI731321 – Glass Cuvettes, 4 pcs – Photometer Series HI 937xx, HI 832xx and HI 7xx

MX-12327

HI731331 – Glass Cuvette 4 pcs. – Serie HI967xx & HI93414 & HI98703

Hanna

HI731331 – Glass Cuvette 4 pcs. – Serie HI967xx & HI93414 & HI98703

MX-12330

HI733 Checker HC ® – Ammonia, HR

Hanna

HI733 Checker HC ® – Ammonia, HR

MX-12334

HI739 Checker HC ® – Fluoride. HR

Hanna

HI739 Checker HC ® – Fluoride. HR

MX-12337

HI740216 Test Tube Cooling Rack for COD measurement

Hanna

HI740216 Test Tube Cooling Rack for COD measurement

MX-12340

HI740217 Lab Safety Shield for COD Measurement

Hanna

HI740217 Lab Safety Shield for COD Measurement

MX-12341

HI749 Checker HC ® – Chromium VI, LR

Hanna

HI749 Checker HC ® – Chromium VI, LR

MX-12350

HI755 Checker HC ® – MARINE Alkalinity (dHK)

Hanna

HI755 Checker HC ® – MARINE Alkalinity (dHK)

MX-12354

HI758 Checker HC ® – MARINE Calcium

Hanna

HI758 Checker HC ® – MARINE Calcium

MX-12355

HI7609829-10 – Ammonium ISE for HI9829 Multiparameter

Hanna

HI7609829-10 – Ammonium ISE for HI9829 Multiparameter

MX-12359

HI7609829-4 – Conductivity / Turbidity Sensor for HI9829 Multiparameter

Hanna

HI7609829-4 – Conductivity / Turbidity Sensor for HI9829 Multiparameter

MX-12364

HI761 Checker HC ® – Total Chlorine, ULR

Hanna

HI761 Checker HC ® – Total Chlorine, ULR

MX-12366

HI762A NTC-Type, Thermistor for air and gases

Hanna

HI762A NTC-Type, Thermistor for air and gases

MX-12377

HI764 Checker HC ® – Nitrite, ULR

Hanna

HI764 Checker HC ® – Nitrite, ULR

MX-12395

HI76410 – Galvanic DO Electrode for HI8410 DO Controller

Hanna

HI76410 – Galvanic DO Electrode for HI8410 DO Controller

MX-12403

HI770 Checker HC ® – Silica, HR

Hanna

HI770 Checker HC ® – Silica, HR

MX-12452

HI771 Checker HC ® – Chlorine, Ultra-High Range

Hanna

HI771 Checker HC ® – Chlorine, Ultra-High Range

MX-12455

HI8410 Dissolved Oxygen Controller with 4 to 20mA

Hanna

HI8410 Dissolved Oxygen Controller with 4 to 20mA

MX-12510

HI93102 Water Analysis Meter (with Turbidity up to 50NTU)

Hanna

HI93102 Water Analysis Meter (with Turbidity up to 50NTU)

MX-12615

HI93102-0 AMCO-AEPA-1 Calibration Solution at 0 NTU, 30 ml

Hanna

HI93102-0 AMCO-AEPA-1 Calibration Solution at 0 NTU, 30 ml

MX-12613

HI93703 Turbidity Meter ISO 7027 Compliant

Hanna

HI93703 Turbidity Meter ISO 7027 Compliant

MX-12648

HI93703-05 AMCO-AEPA-1 Calibration Solution at 500 FTU, 30 ml-Copy

Hanna

HI93703-05 AMCO-AEPA-1 Calibration Solution at 500 FTU, 30 ml-Copy

MX-12643

HI93703-10 AMCO-AEPA-1 Calibration Solution at 10 FTU, 30 ml

Hanna

HI93703-10 AMCO-AEPA-1 Calibration Solution at 10 FTU, 30 ml

MX-12644

HI93703-50 Cuvette Cleaning Solution, 230 ml – (Photometer)

Hanna

HI93703-50 Cuvette Cleaning Solution, 230 ml – (Photometer)

MX-12645

HI93710-01 pH photometric – Reagents- 100 Tests

Hanna

HI93710-01 pH photometric – Reagents- 100 Tests

MX-12661

HI93711-01 Chlorine Total – Reagents – 100 Tests

Hanna

HI93711-01 Chlorine Total – Reagents – 100 Tests

MX-12663

HI93729-01 Fluoride LR – Reagents – 100 Tests

Hanna

HI93729-01 Fluoride LR – Reagents – 100 Tests

MX-12693

HI937520-01 Magnesium – Reagents -50 Tests

Hanna

HI937520-01 Magnesium – Reagents -50 Tests

MX-12730

HI937521-01 Calcium – Reagents – 50 Tests

Hanna

HI937521-01 Calcium – Reagents – 50 Tests

MX-12732

HI96721C Iron Photometer

Hanna

HI96721C Iron Photometer

MX-10203

HI96735-11 CalCheck TM Hardness LR / MR / HR Calibration-Set

Hanna

HI96735-11 CalCheck TM Hardness LR / MR / HR Calibration-Set

MX-12791

HI96785 Farbe von Honig 0 bis 150 mm Pfund – Photometer mobile

Hanna

HI96785 Farbe von Honig 0 bis 150 mm Pfund – Photometer mobile

MX-12806

HI96814 °Oechsle Wein – Digitalrefraktometer tragbar

Hanna

HI96814 °Oechsle Wein – Digitalrefraktometer tragbar

MX-12814

HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter

Hanna

HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter

MX-11459

HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option

Hanna

HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option

MX-12883

HI991300 Multiparameter pH/EC/TDS/°C – EC to 3999 μS

Hanna

HI991300 Multiparameter pH/EC/TDS/°C – EC to 3999 μS

MX-12914

HI991301 Multiparameter pH/EC/TDS/°C – EC to 20.00 mS

Hanna

HI991301 Multiparameter pH/EC/TDS/°C – EC to 20.00 mS

MX-12915

High Range Copper Colorimeter - Checker® HC

Hanna

High Range Copper Colorimeter - Checker® HC

MX-12155

High Range Manganese Colorimeter Checker® HC

Hanna

High Range Manganese Colorimeter Checker® HC

MX-12285

Hydrazine Portable Photometer

Hanna

Hydrazine Portable Photometer

MX-12936

Hydrochloric Acid 0.01N, 1L

Hanna

Hydrochloric Acid 0.01N, 1L

MX-11155

Hydrochloric Acid 0.02N, 1L

Hanna

Hydrochloric Acid 0.02N, 1L

MX-11160

Hydrochloric Acid 0.1N, 1L

Hanna

Hydrochloric Acid 0.1N, 1L

MX-11166

Hydrochloric Acid 1N, 1L

Hanna

Hydrochloric Acid 1N, 1L

MX-11172

Iodine Portable Photometer

Hanna

Iodine Portable Photometer

MX-12943

Iron High Range Portable Portable Photometer

Hanna

Iron High Range Portable Portable Photometer

MX-12947

Iron Low Range & Manganese Low Range Portable Photometer

Hanna

Iron Low Range & Manganese Low Range Portable Photometer

MX-12951

Iron Low Range Checker® HC Calibration Check Set

Hanna

Iron Low Range Checker® HC Calibration Check Set

MX-12344

Iron Low Range Portable Photometer

Hanna

Iron Low Range Portable Photometer

MX-12952

ISO 7027 Compliant Benchtop Turbidity Meter

Hanna

ISO 7027 Compliant Benchtop Turbidity Meter

MX-12568

ISO Turbidity Portable Meter

Hanna

ISO Turbidity Portable Meter

MX-12908

Large Pump Head Assembly

Hanna

Large Pump Head Assembly

MX-12960

Long Calibration Beaker for HI9829 Multiparameter Portable Meter

Hanna

Long Calibration Beaker for HI9829 Multiparameter Portable Meter

MX-12962

Long Protective Probe Shield for HI9829 Multiparameter Portable Meter

Hanna

Long Protective Probe Shield for HI9829 Multiparameter Portable Meter

MX-12963

Long, Quick-Release Flow Cell for HI9829 Multiparameter Portable Meter

Hanna

Long, Quick-Release Flow Cell for HI9829 Multiparameter Portable Meter

MX-12964

Low Range Copper Colorimeter - Checker® HC

Hanna

Low Range Copper Colorimeter - Checker® HC

MX-12349

Low Range Iron Colorimeter - Checker® HC

Hanna

Low Range Iron Colorimeter - Checker® HC

MX-12346

Low Range Silica Portable Photometer

Hanna

Low Range Silica Portable Photometer

MX-12965

Water analysis selection guide

How to choose water testing instruments

01

Specify the result and reporting unit

Write free chlorine or total chlorine, not just chlorine. Include the expected minimum and maximum, reporting unit and decision limit from your method or customer requirement. For example, a value reported as a substance is not automatically interchangeable with a value reported as its constituent element.

02

Compare methods before model counts

Hanna HI97701 measures free chlorine over 0.00 to 5.00 mg/L as Cl₂. For a requirement covering both free and total chlorine, the manufacturer offers HI97711 with separate reagent choices. This illustrates why a quotation must name each result and reagent code, even when instrument ranges look alike.

03

Distinguish a sensor system from a photometer

The HI98494 listed in our catalog uses pH/ORP, conductivity and optical DO sensors. Its multiparameter label does not mean it performs the chlorine photometer methods above. Match every requested parameter to a documented channel, sensor or photometric method.

04

Count tests and replacement supplies

State monthly sample tests plus blanks, quality-control checks and repeats required by the method. For photometers, list reagent codes, pack sizes, cuvettes and storage limits. For sensor systems, include the relevant caps, maintenance solutions and replacement sensors. Compare total recurring requirements rather than assuming one cost always dominates.

05

Plan verification and procurement documents

Request model-specific check standards where appropriate. Hanna HI97701-11, for example, has a certificate carrying its lot, reference values and expiry. Keep a manufacturer quality certificate, a standard certificate and a separately requested calibration service as distinct quotation items. Specify site, cable length and record-export needs.

Include this in a water testing request

  • Each parameter, including free or total chlorine where relevant, and reporting units
  • Expected sample range and the decision limit or specification to assess
  • Required method, sample matrix, meter model and full reagent or replacement-part codes
  • Monthly tests plus the blanks, controls and repeats in your procedure
  • Field or bench use, cable or sampling needs and output format
  • Reagents, check standards, replacement parts, certificates, quantity and delivery province
  • For refills: tests or pieces per pack, packs required, expiry needs and whether cuvette caps are needed

Common water testing questions

Can I request replacement cuvettes or reagent refills without buying a meter?

Yes. Send the meter model, full item code and pack quantity so we can check compatibility and supply. State whether you need cuvettes alone or caps too: Hanna lists HI731331 as a pack of four glass cuvettes without caps. The reagent code and method must also match your existing instrument.

Can I request one instrument for all water parameters?

Start with a parameter matrix. A multiparameter sensor instrument and a multiparameter photometer support different techniques. Mark which device, sensor or method produces each required result before deciding whether one instrument is enough.

Can I use free-chlorine reagents to report total chlorine?

Only use the reagent and procedure specified for the result. Hanna lists HI93701-01 for free chlorine and HI93711-01 for total chlorine in its HI97711 reference guide. Similar packaging or a common instrument does not make the methods interchangeable.

Does a CAL Check standard replace the sample reagent?

No. A model-specific check standard verifies the instrument against a reference; the sample test still uses its stated reagent and procedure. Check which standards are included in the exact kit and which need separate ordering.

How should we compare running costs?

Compare the same workload and verification plan: tests per month, reagents per test, control and repeat use, expiry losses and replaceable sensor parts. Ask for an itemized supply list so a lower instrument price does not conceal an incomplete setup.

Related water bench equipment

Manufacturer methods and ordering references

These references support the named chlorine-method comparison, check-standard documents, sensor-system example and replacement-cuvette pack. Verify the current model, method and kit supplied in Thailand before ordering.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.