Skip to content
ไทย

Water Testing & Analysis

Dissolved oxygen, salinity, turbidity, chlorine and multiparameter meters for water analysis in labs, aquaculture and treatment plants.

Water analysis selection guide

Turn the water-testing requirement into a parameter-by-parameter order

A water-testing setup can combine sensors for pH, conductivity and dissolved oxygen with photometric tests for specific substances. List the result, expected range and required method for each parameter, then quote the instruments and the supplies that each method consumes.

See the checklist and buying questions

399 products · page 7 of 9

Peristaltic Pump Replacement Cap and Rotor for HI921

Hanna

Peristaltic Pump Replacement Cap and Rotor for HI921

MX-13035

Peristaltic Pump Roller Tube for HI921 (3 Sets)

Hanna

Peristaltic Pump Roller Tube for HI921 (3 Sets)

MX-13037

Peristaltic Pump Roller Tube for HI921 (3 Sets)(TYGON E-LFL)

Hanna

Peristaltic Pump Roller Tube for HI921 (3 Sets)(TYGON E-LFL)

MX-13036

pH Photometer Reagents (300 tests)

Hanna

pH Photometer Reagents (300 tests)

MX-12662

pH, Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer

Hanna

pH, Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer

MX-13045

pH, Free and Total Chlorine Photometer

Hanna

pH, Free and Total Chlorine Photometer

MX-13080

pH, Free and Total Chlorine, Total Hardness and Iron Low-Range Portable Photometer

Hanna

pH, Free and Total Chlorine, Total Hardness and Iron Low-Range Portable Photometer

MX-13053

pH/ORP/ISE/DO Advanced Benchtop Meter Kit

Hanna

pH/ORP/ISE/DO Advanced Benchtop Meter Kit

MX-13088

pH/ORP/ISE/EC/TDS/DO Advanced Benchtop Meter Kit

Hanna

pH/ORP/ISE/EC/TDS/DO Advanced Benchtop Meter Kit

MX-13090

Phosphate Low Range Portable Portable Photometer

Hanna

Phosphate Low Range Portable Portable Photometer

MX-13102

Phosphate Portable Photometer

Hanna

Phosphate Portable Photometer

MX-13104

Phosphorus Portable Photometer

Hanna

Phosphorus Portable Photometer

MX-13106

Photometer for Reducing Sugars in Wine

Hanna

Photometer for Reducing Sugars in Wine

MX-12504

Photometer for Tartaric Acid in Wine

Hanna

Photometer for Tartaric Acid in Wine

MX-12506

Photometric Electrodes

Hanna

Photometric Electrodes

MX-13108

Pipette for automatic dosage, Tip for 100 µL graduated pipette (10 pcs)

Hanna

Pipette for automatic dosage, Tip for 100 µL graduated pipette (10 pcs)

MX-13109

Plastic Pipette Tip for Graduated Syringe (6 pcs)

Hanna

Plastic Pipette Tip for Graduated Syringe (6 pcs)

MX-13111

25 Plastic Pipette Tips (1000 µL)

Hanna

Plastic Pipette Tips

3 variants: 4 / 2000 · 25 / 200 · 25 / 1000

Choose a variant
Polarographic Portable Dissolved Oxygen Meter

Hanna

Polarographic Portable Dissolved Oxygen Meter

MX-12603

Pool and Spa Photometer

Hanna

Pool and Spa Photometer

MX-13117

Pool Digital Alkalinity Checker® HC

Hanna

Pool Digital Alkalinity Checker® HC

MX-13118

Pool Digital Free Chlorine Checker® HC

Hanna

Pool Digital Free Chlorine Checker® HC

MX-13124

Pool Line Chlorine removal kit

Hanna

Pool Line Chlorine removal kit

MX-13121

Pool Line Free & Total Chlorine, Cyanuric Acid, and pH Portable Photometer with CAL Check - Meter Only

Hanna

Pool Line Free & Total Chlorine, Cyanuric Acid, and pH Portable Photometer with CAL Check - Meter Only

MX-13126

Pool Line Free Chlorine Checker HC® Calibration Check

Hanna

Pool Line Free Chlorine Checker HC® Calibration Check

MX-13123

Pool Line Phosphate Low Range Checker HC® Colorimeter: Range 0.00 to 2.50 ppm (mg/L)

Hanna

Pool Line Phosphate Low Range Checker HC® Colorimeter: Range 0.00 to 2.50 ppm (mg/L)

MX-13130

Portable COD Meter – HI97106

Hanna

Portable COD Meter – HI97106

MX-12820

Portable Cyanuric Acid Meter – HI97722

Hanna

Portable Cyanuric Acid Meter – HI97722

MX-11420

Portable Dissolved Oxygen Meter

Hanna

Portable Dissolved Oxygen Meter

MX-12605

Portable Dissolved Oxygen Meter for Wine

Hanna

Portable Dissolved Oxygen Meter for Wine

MX-13134

Portable EBC Haze Meter

Hanna

Portable EBC Haze Meter

MX-13135

Portable Multiparameter pH/EC/opdo® Meter with Bluetooth®

Hanna

Portable Multiparameter pH/EC/opdo® Meter with Bluetooth®

MX-13138

Portable Multiparameter pH/EC/Turbidity/opdo® Meter with Bluetooth®

Hanna

Portable Multiparameter pH/EC/Turbidity/opdo® Meter with Bluetooth®

MX-13137

Portable Photometer for Determination of Peroxide Value in Oils

Hanna

Portable Photometer for Determination of Peroxide Value in Oils

MX-12502

Portable Turbidity and Bentonite Check Meter

Hanna

Portable Turbidity and Bentonite Check Meter

MX-12507

Portable Turbidity Meter ISO Compliant

Hanna

Portable Turbidity Meter ISO Compliant

MX-12647

Potassium Hydrogen Phthalate, 20g

Hanna

Potassium Hydrogen Phthalate, 20g

MX-13142

Potassium Low and Medium-Range Portable Photometer

Hanna

Potassium Low and Medium-Range Portable Photometer

MX-13146

Probe Maintenance Kit for HI9829 Multiparameter Portable Meter

Hanna

Probe Maintenance Kit for HI9829 Multiparameter Portable Meter

MX-11446

Protective Cover

Hanna

Protective Cover

MX-13153

Pump Head Assembly

Hanna

Pump Head Assembly

MX-13159

RD125 COD Thermoreactor

Lovibond

RD125 COD Thermoreactor

MX-10181

Replacement Lamp for Turbidity Meter

Hanna

Replacement Lamp for Turbidity Meter

MX-13205

Replacement Propellers

Hanna

Replacement Propellers

MX-13206

Set of 5 Septums

Hanna

Set of 5 Septums

MX-13210

Set of O-Rings

Hanna

Set of O-Rings

MX-13212

Water analysis selection guide

Five decisions behind a water testing quote

01

Specify the result and reporting unit

Write free chlorine or total chlorine, not just chlorine. Include the expected minimum and maximum, reporting unit and decision limit from your method or customer requirement. For example, a value reported as a substance is not automatically interchangeable with a value reported as its constituent element.

02

Compare methods before model counts

Hanna HI97701 measures free chlorine over 0.00 to 5.00 mg/L as Cl₂. For a requirement covering both free and total chlorine, the manufacturer offers HI97711 with separate reagent choices. This illustrates why a quotation must name each result and reagent code, even when instrument ranges look alike.

03

Distinguish a sensor system from a photometer

The HI98494 listed in our catalog uses pH/ORP, conductivity and optical DO sensors. Its multiparameter label does not mean it performs the chlorine photometer methods above. Match every requested parameter to a documented channel, sensor or photometric method.

04

Count tests and replacement supplies

State monthly sample tests plus blanks, quality-control checks and repeats required by the method. For photometers, list reagent codes, pack sizes, cuvettes and storage limits. For sensor systems, include the relevant caps, maintenance solutions and replacement sensors. Compare total recurring requirements rather than assuming one cost always dominates.

05

Plan verification and procurement documents

Request model-specific check standards where appropriate. Hanna HI97701-11, for example, has a certificate carrying its lot, reference values and expiry. Keep a manufacturer quality certificate, a standard certificate and a separately requested calibration service as distinct quotation items. Specify site, cable length and record-export needs.

Include this in a water testing request

  • Each parameter, including free or total chlorine where relevant, and reporting units
  • Expected sample range and the decision limit or specification to assess
  • Required method, sample matrix and existing instrument or reagent codes
  • Monthly tests plus the blanks, controls and repeats in your procedure
  • Field or bench use, cable or sampling needs and output format
  • Reagents, check standards, replacement parts, certificates, quantity and delivery province

Common water testing questions

Can I request one instrument for all water parameters?

Start with a parameter matrix. A multiparameter sensor instrument and a multiparameter photometer support different techniques. Mark which device, sensor or method produces each required result before deciding whether one instrument is enough.

Can I use free-chlorine reagents to report total chlorine?

Only use the reagent and procedure specified for the result. Hanna lists HI93701-01 for free chlorine and HI93711-01 for total chlorine in its HI97711 reference guide. Similar packaging or a common instrument does not make the methods interchangeable.

Does a CAL Check standard replace the sample reagent?

No. A model-specific check standard verifies the instrument against a reference; the sample test still uses its stated reagent and procedure. Check which standards are included in the exact kit and which need separate ordering.

How should we compare running costs?

Compare the same workload and verification plan: tests per month, reagents per test, control and repeat use, expiry losses and replaceable sensor parts. Ask for an itemized supply list so a lower instrument price does not conceal an incomplete setup.

Related water bench equipment

Manufacturer methods and ordering references

These references support the named chlorine-method comparison, check-standard documents and sensor-system example. Verify the current model, method and kit supplied in Thailand before ordering.

This buying guide does not decide which method meets a legal or customer requirement. The laboratory must confirm the accepted method, sample suitability and reporting units; quoted ranges and consumables must match that choice.